Stephanie Brunner
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Stephanie Brunner has a total of 350 co-authors. Here are the top co-authors by number of shared publications:
- Fabien Praz
Department of Cardiology, Bern University Hospital, Bern, Switzerland
11 shared publications Stefan Toggweiler
11 shared publications- Christian Besler
University Heart Center Freiburg/Bad Krozingen Bad Krozingen Germany
10 shared publications - Holger Thiele
Department of Internal Medicine/Cardiology, Heart Center Leipzig at Leipzig University and Leipzig Heart Science , Leipzig
10 shared publications - Jennifer von Stein
Department of Cardiology, Heart Center, University of Cologne, Cologne, Germany; Cardiovascular Research Foundation, New York, New York, USA
10 shared publications - Lukas Stolz
Medizinische Klinik und Poliklinik I, LMU Klinikum, LMU München, Munich, Germany; German Center for Cardiovascular Research (DZHK), Partner Site Munich Heart Alliance, Munich, Germany
10 shared publications
Latest Publications
- 12 November 2026
- Published by Wolters Kluwer Health in Journal of the American Heart Association
Effects of Transcatheter Tricuspid Edge‐to‐Edge Repair on Right Heart Dimension and Function
Background: Transcatheter tricuspid edge‐to‐edge repair (T‐TEER) has developed as a treatment option for patients experiencing severe tricuspid regurgitation. T‐TEER consistently reduces tricuspid regurgitation, but data on subsequent right heart remodeling remain limited. The aim of this study was to evaluate changes in right heart dimension and function after T‐TEER using extended echocardiographic follow‐up. Methods: The study was based on the international EuroTR (European Registry of Transcatheter Repair for Tricuspid Regurgitation), including patients undergoing T‐TEER between 2016 and 2024 at 18 European centers. Eligible were patients with available baseline and follow‐up (≥90 days postprocedure) echocardiographic assessment. Results: A total of 699 patients (mean age, 78±8 years; 56% women) were included in the analysis. Echocardiographic follow‐up was performed at a median of 407 days (interquartile range, 205–801 days). Right heart dimensions significantly decreased: right ventricular (RV) midventricular diameter from 40.2±8.9 to 37.1±8.4 mm ( P 2 ( P P P <0.001) was observed. Conclusions: In the subset of surviving patients with available echocardiographic follow‐up, treatment with T‐TEER led to favorable long‐term changes with reduced RV dimension, associated with procedural success. RV function modestly decreased, likely reflecting normalization after volume unloading.
- 12 November 2026
- Published by Wolters Kluwer Health in Journal of the American Heart Association
Effects of Transcatheter Tricuspid Edge‐to‐Edge Repair on Right Heart Dimension and Function
Background: Transcatheter tricuspid edge‐to‐edge repair (T‐TEER) has developed as a treatment option for patients experiencing severe tricuspid regurgitation. T‐TEER consistently reduces tricuspid regurgitation, but data on subsequent right heart remodeling remain limited. The aim of this study was to evaluate changes in right heart dimension and function after T‐TEER using extended echocardiographic follow‐up. Methods: The study was based on the international EuroTR (European Registry of Transcatheter Repair for Tricuspid Regurgitation), including patients undergoing T‐TEER between 2016 and 2024 at 18 European centers. Eligible were patients with available baseline and follow‐up (≥90 days postprocedure) echocardiographic assessment. Results: A total of 699 patients (mean age, 78±8 years; 56% women) were included in the analysis. Echocardiographic follow‐up was performed at a median of 407 days (interquartile range, 205–801 days). Right heart dimensions significantly decreased: right ventricular (RV) midventricular diameter from 40.2±8.9 to 37.1±8.4 mm ( P 2 ( P P P <0.001) was observed. Conclusions: In the subset of surviving patients with available echocardiographic follow‐up, treatment with T‐TEER led to favorable long‐term changes with reduced RV dimension, associated with procedural success. RV function modestly decreased, likely reflecting normalization after volume unloading.
- 21 September 2026
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 108 (6) , 2203-2211
Short‐ and Long‐Term Outcomes After Transcatheter Aortic Valve Implantation With Large Self‐Expanding Valves
Background: Patients with large aortic annuli are a more challenging subgroup for transcatheter aortic valve implantation (TAVI), and data on long‐term outcomes are sparse. Aims: Compare outcomes of patients with large annular anatomies to outcomes of patients with regular anatomies. Methods: Between January 2015 and November 2025, 488 patients underwent TAVI with different generations of Evolut valves for the treatment of native aortic stenosis. Outcomes of large 34 mm valves were compared to regular size 23−29 mm valves. To account for the nonrandomized design, the primary comparison was performed in a 1:1 propensity score matching cohort. Results: A total of 186 (38%) patients received large and 302 (62%) received regular size valves. Propensity score matching yielded 141 well‐balanced pairs, in whom age (80 ± 6 vs. 81 ± 6 years), STS‐PROM score (3.2 [2.0−4.9] vs. 3.6 [2.1−5.8]), and male sex (96% vs. 97%), were comparable. Procedural technical success (95% vs. 94%), device success (90% vs. 92%), and early safety (79% vs. 79%) were comparable. At 30 days, mortality (2.1% vs. 1.4%), stroke (2.1% vs. 3.5%), and new pacemaker implantation (12% vs. 11%) did not differ significantly. At 5 years, there were no significant differences between the groups in all‐cause mortality (HR 1.06, 95% CI 0.64–1.76, p = 0.8), stroke (sHR 0.74, 95% CI 0.26−2.11, p = 0.6), heart failure rehospitalization (sHR 0.96, 95% CI 0.46−2.01, p =0.9), or new pacemaker implantation (sHR 1.02, 95% CI 0.57−1.82, p = 0.9). Structural valve deterioration stage 3 (0% vs. 1.6%), infective endocarditis (1.7% vs. 2.8%), and valve reintervention (0% vs. 0.9%) were infrequent in both groups. The findings were consistent in the whole‐cohort analysis. Conclusion: Outcomes after TAVI with large self‐expanding valves were comparable to regular size valves, demonstrating favorable results up to 5 years of follow‐up.
- 21 September 2026
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 108 (6) , 2203-2211
Short‐ and Long‐Term Outcomes After Transcatheter Aortic Valve Implantation With Large Self‐Expanding Valves
Background: Patients with large aortic annuli are a more challenging subgroup for transcatheter aortic valve implantation (TAVI), and data on long‐term outcomes are sparse. Aims: Compare outcomes of patients with large annular anatomies to outcomes of patients with regular anatomies. Methods: Between January 2015 and November 2025, 488 patients underwent TAVI with different generations of Evolut valves for the treatment of native aortic stenosis. Outcomes of large 34 mm valves were compared to regular size 23−29 mm valves. To account for the nonrandomized design, the primary comparison was performed in a 1:1 propensity score matching cohort. Results: A total of 186 (38%) patients received large and 302 (62%) received regular size valves. Propensity score matching yielded 141 well‐balanced pairs, in whom age (80 ± 6 vs. 81 ± 6 years), STS‐PROM score (3.2 [2.0−4.9] vs. 3.6 [2.1−5.8]), and male sex (96% vs. 97%), were comparable. Procedural technical success (95% vs. 94%), device success (90% vs. 92%), and early safety (79% vs. 79%) were comparable. At 30 days, mortality (2.1% vs. 1.4%), stroke (2.1% vs. 3.5%), and new pacemaker implantation (12% vs. 11%) did not differ significantly. At 5 years, there were no significant differences between the groups in all‐cause mortality (HR 1.06, 95% CI 0.64–1.76, p = 0.8), stroke (sHR 0.74, 95% CI 0.26−2.11, p = 0.6), heart failure rehospitalization (sHR 0.96, 95% CI 0.46−2.01, p =0.9), or new pacemaker implantation (sHR 1.02, 95% CI 0.57−1.82, p = 0.9). Structural valve deterioration stage 3 (0% vs. 1.6%), infective endocarditis (1.7% vs. 2.8%), and valve reintervention (0% vs. 0.9%) were infrequent in both groups. The findings were consistent in the whole‐cohort analysis. Conclusion: Outcomes after TAVI with large self‐expanding valves were comparable to regular size valves, demonstrating favorable results up to 5 years of follow‐up.
- Open Access
- 28 August 2026
- Published by Elsevier in JACC: Advances
- Vol. 5 (10)
Prognostic Value of NYHA Functional Class in Tricuspid Valve Transcatheter Edge-to-Edge Repair
- 28 August 2026
- Published by Elsevier in JACC: Advances
- Vol. 5 (10)
Open AccessPrognostic Value of NYHA Functional Class in Tricuspid Valve Transcatheter Edge-to-Edge Repair
- 18 August 2026
- Published by Oxford University Press (OUP) in European Heart Journal - Cardiovascular Imaging
- Vol. 27 (11) , 2047-2049
Detection and quantification of left-to-right shunts by magnetic resonance contrast bolus time intensity curves
- 18 August 2026
- Published by Oxford University Press (OUP) in European Heart Journal - Cardiovascular Imaging
- Vol. 27 (11) , 2047-2049
Detection and quantification of left-to-right shunts by magnetic resonance contrast bolus time intensity curves
- Open Access
- 9 April 2026
- Published by Elsevier in JACC: Cardiovascular Interventions
- Vol. 19 (7) , 843-853
Applying the 2025 ESC/EACTS Recommendations for the Treatment of Severe Tricuspid Regurgitation to Real-World Practice
- 9 April 2026
- Published by Elsevier in JACC: Cardiovascular Interventions
- Vol. 19 (7) , 843-853
Open AccessApplying the 2025 ESC/EACTS Recommendations for the Treatment of Severe Tricuspid Regurgitation to Real-World Practice
- 23 March 2026
- Published by Elsevier in JACC: Cardiovascular Interventions
- Vol. 19 (6) , 726-736
Management and Outcome of Failed Transcatheter Tricuspid Edge-to-Edge Repair
- 23 March 2026
- Published by Elsevier in JACC: Cardiovascular Interventions
- Vol. 19 (6) , 726-736
Management and Outcome of Failed Transcatheter Tricuspid Edge-to-Edge Repair
- Top Cited PapersOpen Access
- 9 March 2026
- Published by Elsevier in JACC: Cardiovascular Interventions
- Vol. 19 (5) , 631-646
Predicting Outcomes in Patients With Tricuspid Regurgitation Undergoing Transcatheter Edge-to-Edge Repair Using an Artificial Intelligence–Derived Risk Score
- 9 March 2026
- Published by Elsevier in JACC: Cardiovascular Interventions
- Vol. 19 (5) , 631-646
Top Cited PapersOpen AccessPredicting Outcomes in Patients With Tricuspid Regurgitation Undergoing Transcatheter Edge-to-Edge Repair Using an Artificial Intelligence–Derived Risk Score
- Open Access
- 3 March 2026
- Published by Elsevier in JACC: Cardiovascular Interventions
- Vol. 19 (10) , 1225-1239
Prognostic Value of NT-proBNP in Patients Undergoing Tricuspid Valve Transcatheter Edge-to-Edge Repair
- 3 March 2026
- Published by Elsevier in JACC: Cardiovascular Interventions
- Vol. 19 (10) , 1225-1239
Open AccessPrognostic Value of NT-proBNP in Patients Undergoing Tricuspid Valve Transcatheter Edge-to-Edge Repair
- Open Access
- 26 February 2026
- Published by Elsevier in Structural Heart
- Vol. 10 (8)
Complete Versus Incomplete Revascularization in Patients With Severe Aortic Stenosis Undergoing Complex, High-Risk PCI: Insights From the ASCoP Registry
- 26 February 2026
- Published by Elsevier in Structural Heart
- Vol. 10 (8)
Open AccessComplete Versus Incomplete Revascularization in Patients With Severe Aortic Stenosis Undergoing Complex, High-Risk PCI: Insights From the ASCoP Registry
- Open Access
- 1 January 2026
- Published by BMJ in Open Heart
- Vol. 13 (1) , e004059
Early rehospitalisation after transcatheter aortic valve implantation: incidence, predictors and impact on mortality
Background: Early rehospitalisation after transcatheter aortic valve implantation (TAVI) is frequently required but data regarding its prevalence, aetiology, predictors and prognostic relevance are limited. Methods: We retrospectively analysed consecutive patients undergoing TAVI between August 2012 and October 2025. Early rehospitalisation was defined as any admission within 30 days from the index hospitalisation. Data regarding rehospitalisation causes, predictors, outcomes and impact on mortality were collected. Associations were evaluated using univariable and multivariable logistic and Cox regression models and Kaplan-Meier curve analyses. Results: A total of 1347 patients (43.8% women, mean age 81±6 years) were included. Early rehospitalisation was required in 131 (9.7%), most frequently due to infection (22.9%), heart failure (HF 19.8%) and bradycardia (9.9%). Independent predictors of rehospitalisation for infection were chronic HF (OR 2.60, 95% CI 1.02 to 6.59; p=0.045), chronic obstructive pulmonary disease (OR 3.18, 95% CI 1.27 to 7.96; p=0.013) and contrast dye volume (OR 1.25 per 25 mL increase, 95% CI 1.09 to 1.44; p=0.002). Rehospitalisation for decompensated HF was significantly associated with chronic HF (OR 3.82, 95% CI 1.24 to 11.81; p=0.020), paravalvular leak ≥mild (OR 5.05, 95% CI 1.50 to 16.98; p=0.009) and reduced postprocedural ejection fraction (OR 3.85, 95% CI 1.20 to 12.50; p=0.022). Conduction abnormalities at discharge predicted rehospitalisation for bradycardia requiring pacemaker implantation (OR 4.65, 95% CI 1.39 to 15.57; p=0.013). Early (≤2 days) discharge was not associated with an increased risk of rehospitalisation (27.7% vs 20.3%, p=0.073). 1-year all-cause mortality was higher for the early rehospitalisation group after multivariable adjustment (HR 3.03, 95% CI 1.90 to 4.86; p<0.001). Conclusions: Nearly one-tenth of patients were readmitted after index hospitalisation. The most prevalent causes were infection, HF and bradycardia. Modifiable risk factors were contrast dye volume, ≥mild paravalvular leaks and discharge conduction abnormalities. Early discharge did not predict rehospitalisation. Mortality risk at 1 year was three times higher in patients requiring early rehospitalisation.
- 1 January 2026
- Published by BMJ in Open Heart
- Vol. 13 (1) , e004059
Open AccessEarly rehospitalisation after transcatheter aortic valve implantation: incidence, predictors and impact on mortality
Background: Early rehospitalisation after transcatheter aortic valve implantation (TAVI) is frequently required but data regarding its prevalence, aetiology, predictors and prognostic relevance are limited. Methods: We retrospectively analysed consecutive patients undergoing TAVI between August 2012 and October 2025. Early rehospitalisation was defined as any admission within 30 days from the index hospitalisation. Data regarding rehospitalisation causes, predictors, outcomes and impact on mortality were collected. Associations were evaluated using univariable and multivariable logistic and Cox regression models and Kaplan-Meier curve analyses. Results: A total of 1347 patients (43.8% women, mean age 81±6 years) were included. Early rehospitalisation was required in 131 (9.7%), most frequently due to infection (22.9%), heart failure (HF 19.8%) and bradycardia (9.9%). Independent predictors of rehospitalisation for infection were chronic HF (OR 2.60, 95% CI 1.02 to 6.59; p=0.045), chronic obstructive pulmonary disease (OR 3.18, 95% CI 1.27 to 7.96; p=0.013) and contrast dye volume (OR 1.25 per 25 mL increase, 95% CI 1.09 to 1.44; p=0.002). Rehospitalisation for decompensated HF was significantly associated with chronic HF (OR 3.82, 95% CI 1.24 to 11.81; p=0.020), paravalvular leak ≥mild (OR 5.05, 95% CI 1.50 to 16.98; p=0.009) and reduced postprocedural ejection fraction (OR 3.85, 95% CI 1.20 to 12.50; p=0.022). Conduction abnormalities at discharge predicted rehospitalisation for bradycardia requiring pacemaker implantation (OR 4.65, 95% CI 1.39 to 15.57; p=0.013). Early (≤2 days) discharge was not associated with an increased risk of rehospitalisation (27.7% vs 20.3%, p=0.073). 1-year all-cause mortality was higher for the early rehospitalisation group after multivariable adjustment (HR 3.03, 95% CI 1.90 to 4.86; p<0.001). Conclusions: Nearly one-tenth of patients were readmitted after index hospitalisation. The most prevalent causes were infection, HF and bradycardia. Modifiable risk factors were contrast dye volume, ≥mild paravalvular leaks and discharge conduction abnormalities. Early discharge did not predict rehospitalisation. Mortality risk at 1 year was three times higher in patients requiring early rehospitalisation.