JBJean-François Beaudoin

Jean-François Beaudoin

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jean-François Beaudoin has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Enhanced Extraction of Blood and Tissue Time-Activity Curves in Cardiac Mouse FDG PET Imaging by Means of Constrained Nonnegative Matrix Factorization

    by Otman Sarrhini, Pedro D’oRléans-Juste, Jacques A. Rousseau, Jean-François Beaudoin, Roger Lecomte

    We propose an enhanced method to accurately retrieve time-activity curves (TACs) of blood and tissue from dynamic 2-deoxy-2-[18F]fluoro-D-glucose ([18F]FDG) positron emission tomography (PET) cardiac images of mice. The method is noninvasive and consists of using a constrained nonnegative matrix factorization algorithm (CNMF) applied to the matrix () containing the intensity values of the voxels of the left ventricle (LV) PET image. CNMF factorizes into nonnegative matrices and , respectively, representing the physiological factors (blood and tissue) and their associated weights, by minimizing an extended cost function. We verified our method on 32 C57BL/6 mice, 14 of them with acute myocardial infarction (AMI). With CNMF, we could break down the mouse LV into myocardial and blood pool images. Their corresponding TACs were used in kinetic modeling to readily determine the [18F]FDG influx constant () required to compute the myocardial metabolic rate of glucose. The calculated values using CNMF for the heart of control mice were in good agreement with those published in the literature. Significant differences in values for the heart of control and AMI mice were found using CNMF. The values of the elements of agreed well with the LV structural changes induced by ligation of the left coronary artery. CNMF was compared with the recently published method based on robust unmixing of dynamic sequences using regions of interest (RUDUR). A clear improvement of signal separation was observed with CNMF compared to the RUDUR method.


  • Open Access

    Publisher Correction: Dichotomic effects of clinically used drugs on tumor growth, bone remodeling and pain management

    by David André Barrière, Élora Midavaine, Louis Doré-Savard, Karyn Kirby, Luc Tremblay, Jean-François Beaudoin, Nicolas Beaudet, Jean-Michel Longpré, Roger Lecomte, Martin Lepage, et al.

    An amendment to this paper has been published and can be accessed via a link at the top of the paper.


  • Parameter optimization and effective imaging volume determination of helical scan for a pinhole animal SPECT

    by Rutao Yao, Xiao Deng, Tiantian Dai, Qingyang Wei, Jean-François Beaudoin, Charles Naaman, Tianyu Ma, Jules Cadorette, Roger Lecomte

    We developed SPECT imaging capability on a LabPETTM animal scanner. The add-on SPECT uses a multiplepinhole collimator and a step-and-shoot helical scan scheme. The objective of this work was to determine I) the effective imaging volume of a given scan protocol, and 2) the helical scan parameters, that is, the angular and axial step sizes, for achieving uniform high resolution images throughout the imaging volume. Three rotational step sizes, {1°, 2°, 3°}, and three axial step sizes, {0.3 mm, 0.6 mm, 1.2 mm}, were combined to form 9 helical scan protocols. These step sizes were derived based on the reference values analytically calculated using the spatial resolution of the SPECT system and the Nyquist sampling theorem. Two numerical indices, the sampling completeness percentage (SCP), and the directional resolution (DR), were designed to quantify the projection sampling and resolution performance of the helical protocols. Scanning of a digital sphere-grid phantom centered in the SPECT system's FOV was simulated for each of the 9 helical protocols. Aggregated RMS resolution values derived from the image of distributed spheres over the FOV were used to assess the resolution performance of the scan protocols, and for validating the predictive value of the SCP and DR indices, which were calculated over the matching grid. The RMS results showed that the effective image volume of a helical scan where sampling is adequate was defined by the start and end pinhole planes. The results also showed that using a small axial step size (about half the value derived from Nyquist theorem) achieved best imaging resolution, while the angular step size was less critical. The RMS images correlated well with that of SCP and DR. We conclude the following for designing a helical scan protocol with a multiple pinhole collimator. First, the effective imaging volume should be confined between the start and end planes of the pinholes' movement range. Second, using an axial step size that is half of what is calculated from the Nyquist theorem is desirable for optimal resolution performance. In addition, SCP and DR are useful indices for assessing scan protocols analytically.

  • Open Access

    Positron emission tomography detection of human endothelial cell and fibroblast monolayers: effect of pretreament and cell density on 18FDG uptake

    by Julie A Chouinard, Jacques A Rousseau, Jean-François Beaudoin, Patrick Vermette, Roger Lecomte

    Background The non-destructive assessment and characterization of tridimensional (3D) cell and tissue constructs in bioreactors represents a challenge in tissue engineering. Medical imaging modalities, which can provide information on the structure and function of internal organs and tissues in living organisms, have the potential of allowing repetitive monitoring of these 3D cultures in vitro. Positron emission tomography (PET) is the most sensitive non-invasive imaging modality, capable of measuring picomolar amounts of radiolabeled molecules. However, since PET imaging protocols have been designed almost exclusively for in vivoinvestigations, suitable methods must be devised to enable imaging of cells or tissue substitutes. As a prior step to imaging 3D cultures, cell radiotracer uptake conditions must first be optimized. Methods In this study, human umbilical vein endothelial cells (HUVEC) and human fibroblasts were cultured at different densities and PET was used to non-destructively monitor their glycolytic activity by measuring 18F-fluorodeoxyglucose ( 18FDG) uptake. Various cell preconditioning protocols were investigated by adjusting the following parameters to optimize 18FDG uptake: glucose starvation, insulin stimulation, glucose concentration, 18FDG incubation time, cell density and radiotracer efflux prevention. Results The conditions yielding optimal 18FDG uptake, and hence best detection sensitivity by PET, were as follows: 2-hour cell preconditioning by glucose deprivation with 1-hour insulin stimulation, followed by 1-hour 18FDG incubation and 15-minute stabilization in standard culture medium, prior to rinsing and PET scanning. Conclusions A step-wise dependence of 18FDG uptake on glucose concentration was found, but a linear correlation between PET signal and cell density was observed. Detection thresholds of 36 ± 7 and 21 ± 4 cells were estimated for endothelial cells and fibroblasts, respectively.