Lorena Petrusca
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Lorena Petrusca has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Nicolas Duchateau
INSA-Lyon,CNRS, Inserm, CREATIS UMR 5220, U1294, Univ Lyon, Universit Claude Bernard Lyon 1, Lyon, France
3 shared publications - Francois Varray
INSA-Lyon, Universite Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1294, Lyon, France
2 shared publications - Magalie Viallon
INSA-Lyon, Université Lyon 1
2 shared publications Pierre Croisille
Univ Lyon, CREATIS, UJM-Saint-Etienne, INSA, CNRS UMR 5520, INSERM U1294 , Saint-Etienne F-42023
2 shared publications- Alessandro Ramalli
Department of Information Engineering, University of Florence, Florence, Italy
1 shared publication - Baptiste Pialot
Department of Information Engineering, University of Florence, Florence, Italy
1 shared publication
Latest Publications
- Open Access
- 1 January 2026
- Published by Oxford University Press (OUP) in European Heart Journal - Imaging Methods and Practice
- Vol. 4 (1)
Ischaemia-reperfusion dynamics in acute myocardial infarction experimental swine model: new insights from quantitative CMR
Aims: To reveal the pattern and dynamics of myocardial oedema induced by myocardial infarction (MI) during ischaemia and subsequent reperfusion, that remain largely unknown, as are the factors that contribute to reperfusion injury. To propose a time-resolved dynamic myocardial tissue characterization by quantitative CMR, with T1&T2 mapping and Pixel-wise standardized analysis to circumvent inter-animal differences and subjective ROI positioning. Methods and results: We measured T1&T2 relaxation times at baseline, during a 40-min transient coronary occlusion, and after reperfusion in an open-chest swine MI model (n = 20; 2 shams) using MRI. Myocardial function, early and late gadolinium enhancement were also assessed. Pixel-wise standardized analysis was used to compare the image contents at each pixel across individuals and time points. A significant increase in cardiac T1&T2 times in the ischaemic regions occurred during ischaemia compared with baseline (mean ΔT1 = 118.8 ms i.e. + 11.1%, ΔT2 = 5.6 ms i.e. + 11.3%; P < 0.05). A global significant and marked increase in T1&T2 times further appeared immediately after reperfusion (mean ΔT1 = 256.8 ms i.e. + 23.3% mean ΔT2 = 11.9 ms i.e. + 23.6%, P < 0.001). This increase was associated with myocardial wall thickness changes, with regional and global dysfunction in the ischaemic myocardium. Three different reperfusion patterns were differentiated by the pixel-wise T1 signal analysis: effective reperfusion with microvascular obstruction (MVO), effective reperfusion without MVO and absence of effective reperfusion. We found no correlations between baseline, per-ischaemia, and post-reperfusion native T1&T2 times when effective reperfusion occurred. Conclusion: Objective quantification of tissue response by pixel-wise analysis demonstrated rapid and significant changes in myocardial water content status post-reperfusion, with three different early-reperfusion patterns observed, suggesting distinct reperfusion mechanisms. The water content after reperfusion does not reflect its state before and it does not provide insight into the final tissue status observed within 3 h after recanalization.
- 1 January 2026
- Published by Oxford University Press (OUP) in European Heart Journal - Imaging Methods and Practice
- Vol. 4 (1)
Open AccessIschaemia-reperfusion dynamics in acute myocardial infarction experimental swine model: new insights from quantitative CMR
Aims: To reveal the pattern and dynamics of myocardial oedema induced by myocardial infarction (MI) during ischaemia and subsequent reperfusion, that remain largely unknown, as are the factors that contribute to reperfusion injury. To propose a time-resolved dynamic myocardial tissue characterization by quantitative CMR, with T1&T2 mapping and Pixel-wise standardized analysis to circumvent inter-animal differences and subjective ROI positioning. Methods and results: We measured T1&T2 relaxation times at baseline, during a 40-min transient coronary occlusion, and after reperfusion in an open-chest swine MI model (n = 20; 2 shams) using MRI. Myocardial function, early and late gadolinium enhancement were also assessed. Pixel-wise standardized analysis was used to compare the image contents at each pixel across individuals and time points. A significant increase in cardiac T1&T2 times in the ischaemic regions occurred during ischaemia compared with baseline (mean ΔT1 = 118.8 ms i.e. + 11.1%, ΔT2 = 5.6 ms i.e. + 11.3%; P < 0.05). A global significant and marked increase in T1&T2 times further appeared immediately after reperfusion (mean ΔT1 = 256.8 ms i.e. + 23.3% mean ΔT2 = 11.9 ms i.e. + 23.6%, P < 0.001). This increase was associated with myocardial wall thickness changes, with regional and global dysfunction in the ischaemic myocardium. Three different reperfusion patterns were differentiated by the pixel-wise T1 signal analysis: effective reperfusion with microvascular obstruction (MVO), effective reperfusion without MVO and absence of effective reperfusion. We found no correlations between baseline, per-ischaemia, and post-reperfusion native T1&T2 times when effective reperfusion occurred. Conclusion: Objective quantification of tissue response by pixel-wise analysis demonstrated rapid and significant changes in myocardial water content status post-reperfusion, with three different early-reperfusion patterns observed, suggesting distinct reperfusion mechanisms. The water content after reperfusion does not reflect its state before and it does not provide insight into the final tissue status observed within 3 h after recanalization.
- 16 July 2025
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 196 (Pt B) , 110643
Comparison of synthetic LGE with optimal inversion time vs. conventional LGE via representation learning: Quantification of Bias in Population Analysis
- 16 July 2025
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 196 (Pt B) , 110643
Comparison of synthetic LGE with optimal inversion time vs. conventional LGE via representation learning: Quantification of Bias in Population Analysis
- 29 June 2023
- Published by Elsevier in Ultrasonics
- Vol. 134, 107099
A simplified and accelerated implementation of SVD for filtering ultrafast power Doppler images
- 29 June 2023
- Published by Elsevier in Ultrasonics
- Vol. 134, 107099
A simplified and accelerated implementation of SVD for filtering ultrafast power Doppler images
- 16 June 2023
- Published by Springer Nature
- p. 678-687
Assessment of the Evolution of Temporal Segmental Strain in a Longitudinal Study of Myocardial Infarction
- 16 June 2023
- Published by Springer Nature
- p. 678-687
Assessment of the Evolution of Temporal Segmental Strain in a Longitudinal Study of Myocardial Infarction
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 2045-2048
Experimental validation of a novel technique for ultrasound imaging of cardiac fiber orientation
The arrangement of cardiac fibers determines mechanical and electrical properties of the heart and can be altered due to pathology. Hence, the non-invasive assessment of fiber characteristics is of interest from both a pathophysiologic and a diagnostic point of view. Recently, we proposed and validated, by computer simulations, a theoretical framework to have more insight on 3D ultrasound Backscatter Tensor Imaging. The theory showed that spatial coherence (SC) maps of echo signals, across the probe aperture, not only carry information on fiber direction, but also on fiber size and pitch. The aim of this study was to experimentally validate these findings and conduct preliminary in vivo tests. Experiments were conducted on a purposely designed and built phantom consisting of several sets of parallel nylon wires, having different diameter (S) and pitch (P). Finally, preliminary tests were conducted on the biceps of healthy volunteers. Experiments confirmed the simulation results: averaged over all acquisitions, the main-to-secondary lobe distance linearly correlated with P (R 2 =94%), while the value of the SC at lag 1 (an estimate of the main lobe width) linearly correlated with S (R 2 =48.6%). In vivo results demonstrated the feasibility of extracting microstructural information of the tissue by the analysis of SC maps.
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 2045-2048
Experimental validation of a novel technique for ultrasound imaging of cardiac fiber orientation
The arrangement of cardiac fibers determines mechanical and electrical properties of the heart and can be altered due to pathology. Hence, the non-invasive assessment of fiber characteristics is of interest from both a pathophysiologic and a diagnostic point of view. Recently, we proposed and validated, by computer simulations, a theoretical framework to have more insight on 3D ultrasound Backscatter Tensor Imaging. The theory showed that spatial coherence (SC) maps of echo signals, across the probe aperture, not only carry information on fiber direction, but also on fiber size and pitch. The aim of this study was to experimentally validate these findings and conduct preliminary in vivo tests. Experiments were conducted on a purposely designed and built phantom consisting of several sets of parallel nylon wires, having different diameter (S) and pitch (P). Finally, preliminary tests were conducted on the biceps of healthy volunteers. Experiments confirmed the simulation results: averaged over all acquisitions, the main-to-secondary lobe distance linearly correlated with P (R 2 =94%), while the value of the SC at lag 1 (an estimate of the main lobe width) linearly correlated with S (R 2 =48.6%). In vivo results demonstrated the feasibility of extracting microstructural information of the tissue by the analysis of SC maps.