Yudong Zhao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yudong Zhao has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Weishi Li
Department of Orthopaedics, Peking University Third Hospital, Beijing 100191, China
6 shared publications - Siyu Zhou
Department of Orthopaedics, Peking University Third Hospital, Beijing, China
5 shared publications - HongBin He
Peking University Health Science Center, Beijing, China
4 shared publications - Zhuoran Sun
Department of Orthopaedics, Peking University Third Hospital, Beijing 100191, China
3 shared publications - Jialiang Lin
Department of Orthopaedics, Peking University Third Hospital, Beijing, China
2 shared publications Li Zhang
Department of Orthopedics, the Second Affiliated Hospital of Kunming Medical University, Kunming, China
2 shared publications
Latest Publications
- Open Access
- 21 October 2026
- Published by MDPI AG in Micromachines
- Vol. 17 (10) , 1210
Wearable Soft Sensors for Spinal Monitoring: Soft Materials, Multimodal Integration, and Clinical Translation
Spinal musculoskeletal disorders demand continuous assessment of movement and loading, whereas routine clinical imaging provides important but episodic structural information. While wearable soft sensors offer a non-invasive approach to complement these assessments, translating laboratory-scale prototypes into robust clinical systems remains challenging because of electromechanical stability, signal fidelity, and data interpretation. This review critically examines the end-to-end development of soft wearable technologies for spinal monitoring, moving beyond a materials-focused survey to address these translational gaps. First, we evaluate advances in soft sensing mechanisms, highlighting the trade-offs between mechanical compliance and stable sensor performance. We then examine system-level integration, including soft or flexible sensing elements, conventional sensors on compliant substrates, rigid–soft interfaces, and multimodal systems for monitoring posture, motion, pressure, and muscle activity. Furthermore, we discuss signal-processing and artificial intelligence-assisted workflows for denoising and extracting meaningful physiological features. By comparing reported performance metrics and validation settings, we assess representative applications in scoliosis and chronic low back pain. Current evidence demonstrates technical feasibility in laboratory tests and small studies, but does not yet establish broad diagnostic benefit or routine clinical effectiveness. Finally, we identify key evidence gaps, including external validation, patient-based studies, standardized protocols, and long-term assessment, that must be addressed for clinical translation.
- 21 October 2026
- Published by MDPI AG in Micromachines
- Vol. 17 (10) , 1210
Open AccessWearable Soft Sensors for Spinal Monitoring: Soft Materials, Multimodal Integration, and Clinical Translation
Spinal musculoskeletal disorders demand continuous assessment of movement and loading, whereas routine clinical imaging provides important but episodic structural information. While wearable soft sensors offer a non-invasive approach to complement these assessments, translating laboratory-scale prototypes into robust clinical systems remains challenging because of electromechanical stability, signal fidelity, and data interpretation. This review critically examines the end-to-end development of soft wearable technologies for spinal monitoring, moving beyond a materials-focused survey to address these translational gaps. First, we evaluate advances in soft sensing mechanisms, highlighting the trade-offs between mechanical compliance and stable sensor performance. We then examine system-level integration, including soft or flexible sensing elements, conventional sensors on compliant substrates, rigid–soft interfaces, and multimodal systems for monitoring posture, motion, pressure, and muscle activity. Furthermore, we discuss signal-processing and artificial intelligence-assisted workflows for denoising and extracting meaningful physiological features. By comparing reported performance metrics and validation settings, we assess representative applications in scoliosis and chronic low back pain. Current evidence demonstrates technical feasibility in laboratory tests and small studies, but does not yet establish broad diagnostic benefit or routine clinical effectiveness. Finally, we identify key evidence gaps, including external validation, patient-based studies, standardized protocols, and long-term assessment, that must be addressed for clinical translation.
- 6 August 2026
- Published by Wolters Kluwer Health in Spine
Development and Initial Validation of Patient-reported Lumbar Surgery Quality of Life (LSQoL)
Study Design.: A mixed-methods study. Objective.: To develop and perform the initial validation of the Lumbar Surgery Quality of Life (LSQoL), a multidimensional patient-reported outcome measure for patients with lumbar degenerative diseases. Summary of background data.: Patient-reported outcome measures (PROMs) are widely used to evaluate outcomes in lumbar degenerative diseases but are often applied in combination, with each instrument capturing only specific aspects of patient status. Consequently, improvement in traditional measures such as the Oswestry Disability Index (ODI) does not always correspond to patient-perceived recovery or satisfaction, highlighting the need for multidimensional tools that better reflect patient experience. Methods.: The LSQoL was developed using a multistage mixed-method approach, including literature review, patient interviews, expert consensus through the Delphi method, and weighting via the Analytic Hierarchy Process (AHP). The instrument was validated in 1,996 patients with lumbar degenerative diseases. Internal consistency, test–retest reliability, construct validity, and correlations with established PROMs and patient-reported recovery and satisfaction were evaluated. Results.: The LSQoL consists of 21 items across five dimensions: pain, neurological function, activities of daily living, emotional status, and working ability. Internal consistency was acceptable to good (Cronbach’s α: 0.744–0.805), and test–retest reliability was strong (ICC: 0.759–0.906). Factor analyses supported a stable multidimensional structure. The LSQoL demonstrated moderate correlations with established PROMs and stronger correlations with patient-reported recovery and satisfaction. Conclusion.: The LSQoL is a reliable and valid PROM that provides a comprehensive assessment of quality of life in patients with lumbar degenerative diseases. It is suitable for evaluating patient-reported outcomes both before and after lumbar surgery.
- 6 August 2026
- Published by Wolters Kluwer Health in Spine
Development and Initial Validation of Patient-reported Lumbar Surgery Quality of Life (LSQoL)
Study Design.: A mixed-methods study. Objective.: To develop and perform the initial validation of the Lumbar Surgery Quality of Life (LSQoL), a multidimensional patient-reported outcome measure for patients with lumbar degenerative diseases. Summary of background data.: Patient-reported outcome measures (PROMs) are widely used to evaluate outcomes in lumbar degenerative diseases but are often applied in combination, with each instrument capturing only specific aspects of patient status. Consequently, improvement in traditional measures such as the Oswestry Disability Index (ODI) does not always correspond to patient-perceived recovery or satisfaction, highlighting the need for multidimensional tools that better reflect patient experience. Methods.: The LSQoL was developed using a multistage mixed-method approach, including literature review, patient interviews, expert consensus through the Delphi method, and weighting via the Analytic Hierarchy Process (AHP). The instrument was validated in 1,996 patients with lumbar degenerative diseases. Internal consistency, test–retest reliability, construct validity, and correlations with established PROMs and patient-reported recovery and satisfaction were evaluated. Results.: The LSQoL consists of 21 items across five dimensions: pain, neurological function, activities of daily living, emotional status, and working ability. Internal consistency was acceptable to good (Cronbach’s α: 0.744–0.805), and test–retest reliability was strong (ICC: 0.759–0.906). Factor analyses supported a stable multidimensional structure. The LSQoL demonstrated moderate correlations with established PROMs and stronger correlations with patient-reported recovery and satisfaction. Conclusion.: The LSQoL is a reliable and valid PROM that provides a comprehensive assessment of quality of life in patients with lumbar degenerative diseases. It is suitable for evaluating patient-reported outcomes both before and after lumbar surgery.
- 8 November 2025
- Published by Springer Nature in European Spine Journal
- Vol. 35 (6) , 3333-3341
Pelvic position significantly influences the segmental lumbar lordosis: a cross-sectional study in asymptomatic population
Purpose In the concept of lumbar surgical planning, it was often seen as a linear relationship between Pelvic Incidence (PI) and Lumbar Lordosis (LL) that a bigger PI referred to a larger LL. While the discovery and high prevalence of pelvic anteversion (AP) population indicated otherwise. The goal of this study was to investigate the influence of pelvic anteversion on lumbar sagittal parameters and elucidate the different PI-related lordosis patterns in asymptomatic population. Methods A total of 405 asymptomatic subjects were divided by their pelvic property into 2 groups: the anteverted pelvis (AP) group (n = 151) and the non-AP group (n = 254). Spinopelvic parameters including PI, pelvic tilt (PT), LL, sacral slope (SS), sagittal vertical axis (SVA), T1 Pelvic angle (TPA), thoracolumbar kyphosis (TLK), lumbar tilt (LT), lumbar lordosis distribution (LDI) and segmental lordosis were measured in whole spine radiographs. Propensity score matching (PSM) was used to establish a PI-balanced cohort. Subsequently, the differences of spinopelvic parameters were assessed between AP and non-AP group. We also conducted a stratified analysis to explore the relationship between different pelvic incidence (PI) levels and segmental lordosis. Results The AP group showed distinct sagittal parameters and PI-related lordosis patterns comparing to non-AP group. The AP group showed lower PI (41.5°±6.0°), PT (4.7°±2.7°), and higher SS (37.3°±5.4°) and LL (53.0°±8.6°) than non-AP group. After propensity score matching, the cohort of 268 subjects showed no significant differences in demographic data (P > 0.1) or PI (P = 0.364) between the AP and non-AP groups. However, significant differences in PT, SS, LL, TPA, L5-S1, L4-5, L3-4, L2-3, upper lumbar lordosis (L1-4) and lower lumbar lordosis (L4-S1) were observed between the two groups (P < 0.01). Only L1-2 segmental lordosis displayed no significant difference between the 2 groups (P = 0.39). In addition, in each PI level, the AP group showed consistently greater LL and segmental lordosis compared to the non-AP group, with the most notable differences in the lower lumbar segments. Conclusion The AP group, characterized by lower PI and PT, and higher SS and LL, should be recognized as a distinct population from the non-AP group. This group also exhibits unique PI-related lordosis patterns, with consistently significant variations in segmental lordosis within each PI level compared to the non-AP group, particularly in the lower lumbar spine.
- 8 November 2025
- Published by Springer Nature in European Spine Journal
- Vol. 35 (6) , 3333-3341
Pelvic position significantly influences the segmental lumbar lordosis: a cross-sectional study in asymptomatic population
Purpose In the concept of lumbar surgical planning, it was often seen as a linear relationship between Pelvic Incidence (PI) and Lumbar Lordosis (LL) that a bigger PI referred to a larger LL. While the discovery and high prevalence of pelvic anteversion (AP) population indicated otherwise. The goal of this study was to investigate the influence of pelvic anteversion on lumbar sagittal parameters and elucidate the different PI-related lordosis patterns in asymptomatic population. Methods A total of 405 asymptomatic subjects were divided by their pelvic property into 2 groups: the anteverted pelvis (AP) group (n = 151) and the non-AP group (n = 254). Spinopelvic parameters including PI, pelvic tilt (PT), LL, sacral slope (SS), sagittal vertical axis (SVA), T1 Pelvic angle (TPA), thoracolumbar kyphosis (TLK), lumbar tilt (LT), lumbar lordosis distribution (LDI) and segmental lordosis were measured in whole spine radiographs. Propensity score matching (PSM) was used to establish a PI-balanced cohort. Subsequently, the differences of spinopelvic parameters were assessed between AP and non-AP group. We also conducted a stratified analysis to explore the relationship between different pelvic incidence (PI) levels and segmental lordosis. Results The AP group showed distinct sagittal parameters and PI-related lordosis patterns comparing to non-AP group. The AP group showed lower PI (41.5°±6.0°), PT (4.7°±2.7°), and higher SS (37.3°±5.4°) and LL (53.0°±8.6°) than non-AP group. After propensity score matching, the cohort of 268 subjects showed no significant differences in demographic data (P > 0.1) or PI (P = 0.364) between the AP and non-AP groups. However, significant differences in PT, SS, LL, TPA, L5-S1, L4-5, L3-4, L2-3, upper lumbar lordosis (L1-4) and lower lumbar lordosis (L4-S1) were observed between the two groups (P < 0.01). Only L1-2 segmental lordosis displayed no significant difference between the 2 groups (P = 0.39). In addition, in each PI level, the AP group showed consistently greater LL and segmental lordosis compared to the non-AP group, with the most notable differences in the lower lumbar segments. Conclusion The AP group, characterized by lower PI and PT, and higher SS and LL, should be recognized as a distinct population from the non-AP group. This group also exhibits unique PI-related lordosis patterns, with consistently significant variations in segmental lordosis within each PI level compared to the non-AP group, particularly in the lower lumbar spine.
- Open Access
- 21 October 2025
- Published by MDPI AG in Diagnostics
- Vol. 15 (20) , 2657
Application of Nanogenerators in Lumbar Motion Monitoring: Fundamentals, Current Status, and Perspectives
Nanogenerators (NGs), especially triboelectric nanogenerators (TENGs), represent an emerging technology with great potential for self-powered lumbar motion monitoring. Conventional wearable systems for assessing spinal kinematics are often limited by their reliance on external power supplies, hindering long-term and real-time clinical applications. NGs can convert biomechanical energy from lumbar motion into electrical energy, providing both sensing and power-generation capabilities in a single platform. This review summarizes the fundamental working mechanisms, device architectures, and current progress of NG-based motion monitoring technologies, with a particular focus on their applications in lumbar spine research and clinical rehabilitation. By enabling high-sensitivity, continuous, and battery-free monitoring, NG-based systems may enhance the diagnosis and management of low back pain (LBP) and postoperative recovery assessment. Furthermore, the integration of NGs with wearable electronics, the Internet of Things (IoT), and artificial intelligence (AI) holds promise for developing intelligent, self-sustaining monitoring platforms that bridge biomedical engineering and spine medicine.
- 21 October 2025
- Published by MDPI AG in Diagnostics
- Vol. 15 (20) , 2657
Open AccessApplication of Nanogenerators in Lumbar Motion Monitoring: Fundamentals, Current Status, and Perspectives
Nanogenerators (NGs), especially triboelectric nanogenerators (TENGs), represent an emerging technology with great potential for self-powered lumbar motion monitoring. Conventional wearable systems for assessing spinal kinematics are often limited by their reliance on external power supplies, hindering long-term and real-time clinical applications. NGs can convert biomechanical energy from lumbar motion into electrical energy, providing both sensing and power-generation capabilities in a single platform. This review summarizes the fundamental working mechanisms, device architectures, and current progress of NG-based motion monitoring technologies, with a particular focus on their applications in lumbar spine research and clinical rehabilitation. By enabling high-sensitivity, continuous, and battery-free monitoring, NG-based systems may enhance the diagnosis and management of low back pain (LBP) and postoperative recovery assessment. Furthermore, the integration of NGs with wearable electronics, the Internet of Things (IoT), and artificial intelligence (AI) holds promise for developing intelligent, self-sustaining monitoring platforms that bridge biomedical engineering and spine medicine.
- Open Access
- 12 June 2023
- Published by MDPI AG in Bioengineering
- Vol. 10 (6) , 713
Intervertebral Disc Progenitors: Lessons Learned from Single-Cell RNA Sequencing and the Role in Intervertebral Disc Regeneration
The tremendous personal and economic burden worldwide caused by low back pain (LBP) has been surging in recent years. While intervertebral disc degeneration (IVDD) is the leading cause of LBP and vast efforts have been made to develop effective therapies, this problem is far from being resolved, as most treatments, such as painkillers and surgeries, mainly focus on relieving the symptoms rather than reversing the cause of IVDD. However, as stem/progenitor cells possess the potential to regenerate IVD, a deeper understanding of the early development and role of these cells could help to improve the effectiveness of stem/progenitor cell therapy in treating LBP. Single-cell RNA sequencing results provide fresh insights into the heterogeneity and development patterns of IVD progenitors; additionally, we compare mesenchymal stromal cells and IVD progenitors to provide a clearer view of the optimal cell source proposed for IVD regeneration.
- 12 June 2023
- Published by MDPI AG in Bioengineering
- Vol. 10 (6) , 713
Open AccessIntervertebral Disc Progenitors: Lessons Learned from Single-Cell RNA Sequencing and the Role in Intervertebral Disc Regeneration
The tremendous personal and economic burden worldwide caused by low back pain (LBP) has been surging in recent years. While intervertebral disc degeneration (IVDD) is the leading cause of LBP and vast efforts have been made to develop effective therapies, this problem is far from being resolved, as most treatments, such as painkillers and surgeries, mainly focus on relieving the symptoms rather than reversing the cause of IVDD. However, as stem/progenitor cells possess the potential to regenerate IVD, a deeper understanding of the early development and role of these cells could help to improve the effectiveness of stem/progenitor cell therapy in treating LBP. Single-cell RNA sequencing results provide fresh insights into the heterogeneity and development patterns of IVD progenitors; additionally, we compare mesenchymal stromal cells and IVD progenitors to provide a clearer view of the optimal cell source proposed for IVD regeneration.