Chia-Hung Kao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Chia-Hung Kao has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
- Ruoh-Fang Yen
Department of Nuclear Medicine, National Taiwan University Hospital, Taipei, Taiwan
4 shared publications - Feng-Yuan Liu
Department of Nuclear Medicine and Molecular Imaging Center, Chang Gung Memorial Hospital, Chang Gung University College of Medicine, Taoyuan, Taiwan
3 shared publications Yu-Chien Shiau
Far Eastern Memorial Hospital
3 shared publicationsJhi-Joung Wang
Chi-Mei Medical Center
2 shared publicationsLee C.
Taiwan
2 shared publicationsLin C.
Yuh-Der Road, Taichung
2 shared publications
Latest Publications
- 1 October 2003
- Published by Springer Nature in Annals of Nuclear Medicine
- Vol. 17 (7) , 521-524
Differentiation of prostate cancer and benign prostatic hyperplasia: the clinical value of 201Tl SPECT--a pilot study.
- 1 October 2003
- Published by Springer Nature in Annals of Nuclear Medicine
- Vol. 17 (7) , 521-524
Differentiation of prostate cancer and benign prostatic hyperplasia: the clinical value of 201Tl SPECT--a pilot study.
- 1 September 2003
- Published by Springer Nature in Annals of Nuclear Medicine
- Vol. 17 (6) , 439-442
Comparison of gallium-67 citrate and technetium-99m tetrofosmin scan to detect Hodgkin’s disease
- 1 September 2003
- Published by Springer Nature in Annals of Nuclear Medicine
- Vol. 17 (6) , 439-442
Comparison of gallium-67 citrate and technetium-99m tetrofosmin scan to detect Hodgkin’s disease
- 21 July 2003
- Published by Wiley in Head & Neck
- Vol. 25 (8) , 645-648
Using thallium-201 SPECT to detect recurrent or residual nasopharyngeal carcinoma after radiotherapy in patients with indeterminate CT findings
- 21 July 2003
- Published by Wiley in Head & Neck
- Vol. 25 (8) , 645-648
Using thallium-201 SPECT to detect recurrent or residual nasopharyngeal carcinoma after radiotherapy in patients with indeterminate CT findings
18‐Fluoro‐2‐deoxyglucose positron emission tomography in detecting residual/recurrent nasopharyngeal carcinomas and comparison with magnetic resonance imaging
BACKGROUND: It is known that 18‐fluoro‐2‐deoxyglucose positron emission tomography (FDG‐PET) is effective in the early detection of residual/recurrent nasopharyngeal carcinomas (NPC). To compare FDG‐PET with the conventional magnetic resonance imaging (MRI) for the detection of residual/recurrent NPC, the authors studied 67 follow‐up cases of patients with NPC using both FDG‐PET and MRI.METHODS: From February 1997 to February 2001, 67 NPC patients (14 women, 53 men; age range, 16–67 years; mean age, 46.6 ± 12.5 years) were recruited. Both FDG‐PET and MRI of the head and neck area for each patient were performed at least 4 months (duration range, 4–70 months; mean, 14 ± 13.5 months) after radiotherapy or radiotherapy with concurrent chemotherapy. The final diagnosis was confirmed by biopsy or clinical follow‐up for at least 6 months.RESULTS: The sensitivity, specificity, accuracy, positive predictive value (PPV), and negative predictive value (NPV) of FDG‐PET images were 100%, 93.4%, 95.5%, 87.5%, and 100%, respectively. In contrast, the sensitivity, specificity, accuracy, PPV, and NPV of the MRI scans were 61.9%, 43.5%, 49.3%, 33.3%, and 70.0%, respectively.CONCLUSIONS: The results of the current study suggest that FDG‐PET is much more effective than MRI in detecting residual/recurrent NPC. Cancer 2003;98:283–7. © 2003 American Cancer Society.DOI 10.1002/cncr.11519
18‐Fluoro‐2‐deoxyglucose positron emission tomography in detecting residual/recurrent nasopharyngeal carcinomas and comparison with magnetic resonance imaging
BACKGROUND: It is known that 18‐fluoro‐2‐deoxyglucose positron emission tomography (FDG‐PET) is effective in the early detection of residual/recurrent nasopharyngeal carcinomas (NPC). To compare FDG‐PET with the conventional magnetic resonance imaging (MRI) for the detection of residual/recurrent NPC, the authors studied 67 follow‐up cases of patients with NPC using both FDG‐PET and MRI.METHODS: From February 1997 to February 2001, 67 NPC patients (14 women, 53 men; age range, 16–67 years; mean age, 46.6 ± 12.5 years) were recruited. Both FDG‐PET and MRI of the head and neck area for each patient were performed at least 4 months (duration range, 4–70 months; mean, 14 ± 13.5 months) after radiotherapy or radiotherapy with concurrent chemotherapy. The final diagnosis was confirmed by biopsy or clinical follow‐up for at least 6 months.RESULTS: The sensitivity, specificity, accuracy, positive predictive value (PPV), and negative predictive value (NPV) of FDG‐PET images were 100%, 93.4%, 95.5%, 87.5%, and 100%, respectively. In contrast, the sensitivity, specificity, accuracy, PPV, and NPV of the MRI scans were 61.9%, 43.5%, 49.3%, 33.3%, and 70.0%, respectively.CONCLUSIONS: The results of the current study suggest that FDG‐PET is much more effective than MRI in detecting residual/recurrent NPC. Cancer 2003;98:283–7. © 2003 American Cancer Society.DOI 10.1002/cncr.11519
- 1 July 2003
- Published by Rockefeller University Press
- Vol. 28 (7) , 610
Incidental findings of FDG uptake in dental caries.
- 1 July 2003
- Published by Rockefeller University Press
- Vol. 28 (7) , 610
Incidental findings of FDG uptake in dental caries.
- 1 March 2003
- Published by Wolters Kluwer Health in Clinical Nuclear Medicine
- Vol. 28 (3) , 249
FDG Uptake in a Huge Uterine Myoma
- 1 March 2003
- Published by Wolters Kluwer Health in Clinical Nuclear Medicine
- Vol. 28 (3) , 249
FDG Uptake in a Huge Uterine Myoma
- 13 November 2002
- Published by Wiley in Head & Neck
- Vol. 25 (3) , 227-231
Detection of recurrent nasopharyngeal carcinomas with thallium-201 single-photon emission computed tomography in patients with indeterminate magnetic resonance imaging findings after radiotherapy
- 13 November 2002
- Published by Wiley in Head & Neck
- Vol. 25 (3) , 227-231
Detection of recurrent nasopharyngeal carcinomas with thallium-201 single-photon emission computed tomography in patients with indeterminate magnetic resonance imaging findings after radiotherapy
- 4 July 2002
- Published by Springer Nature in Pediatric Radiology
- Vol. 32 (9) , 663-666
Improving the diagnosis of acute appendicitis in children with atypical clinical findings using the technetium-99m hexamethylpropylene amine oxime-labelled white-blood-cell abdomen scan
Background. Diagnosing acute appendicitis in children with equivocal signs and symptoms may be difficult. The usual approach is hospital observation and frequent re-examination. However, many surgeons are reluctant to delay surgery because of the risk of perforation and a negative laparotomy. Objective. To assess and compare the value of the technetium-99m hexamethylpropylene amine oxime (99mTc-HMPAO)-labelled white-blood-cell (WBC) abdomen scan in the diagnosis of acute appendicitis in children with atypical clinical presentation. Patients and methods. Fifty children with acute right lower quadrant abdominal pain and possible acute appendicitis, but atypical findings were included. After IV injection of 99mTc-HMPAO-labelled WBCs, serial anterior abdomen scans were obtained using a gamma camera. Results. Thirty-three children underwent surgery, while 17 children were managed conservatively and were followed up for at least 1 month. Four children had false-positive results and one child had a false-negative scan result. The overall sensitivity, specificity, accuracy, positive predictive value and negative predictive value of the scan to diagnose acute appendicitis in children with atypical findings was 96.7, 80.0, 90.0, 87.8 and 94.1%, respectively. Conclusions. The 99mTc-HMPAO WBC abdomen scan is a potential tool for diagnosing acute appendicitis in children with atypical clinical findings. The high sensitivity and negative predictive value allows early discharge from the emergency department to avoid costly observation in hospital and potentially unnecessary surgery in those patients with negative scans.
- 4 July 2002
- Published by Springer Nature in Pediatric Radiology
- Vol. 32 (9) , 663-666
Improving the diagnosis of acute appendicitis in children with atypical clinical findings using the technetium-99m hexamethylpropylene amine oxime-labelled white-blood-cell abdomen scan
Background. Diagnosing acute appendicitis in children with equivocal signs and symptoms may be difficult. The usual approach is hospital observation and frequent re-examination. However, many surgeons are reluctant to delay surgery because of the risk of perforation and a negative laparotomy. Objective. To assess and compare the value of the technetium-99m hexamethylpropylene amine oxime (99mTc-HMPAO)-labelled white-blood-cell (WBC) abdomen scan in the diagnosis of acute appendicitis in children with atypical clinical presentation. Patients and methods. Fifty children with acute right lower quadrant abdominal pain and possible acute appendicitis, but atypical findings were included. After IV injection of 99mTc-HMPAO-labelled WBCs, serial anterior abdomen scans were obtained using a gamma camera. Results. Thirty-three children underwent surgery, while 17 children were managed conservatively and were followed up for at least 1 month. Four children had false-positive results and one child had a false-negative scan result. The overall sensitivity, specificity, accuracy, positive predictive value and negative predictive value of the scan to diagnose acute appendicitis in children with atypical findings was 96.7, 80.0, 90.0, 87.8 and 94.1%, respectively. Conclusions. The 99mTc-HMPAO WBC abdomen scan is a potential tool for diagnosing acute appendicitis in children with atypical clinical findings. The high sensitivity and negative predictive value allows early discharge from the emergency department to avoid costly observation in hospital and potentially unnecessary surgery in those patients with negative scans.
- 1 June 2002
- Published by Springer Nature in Journal of Cancer Research and Clinical Oncology
- Vol. 128 (6) , 325-328
Comparing whole body 18 F-2-deoxyglucose positron emission tomography and technetium-99m methylene diphosphonate bone scan to detect bone metastases in patients with breast cancer
Purpose. At present, bone metastases are usually assessed using conventional technetium-99m methylene diphosphonate whole-body bone scan, which has a high sensitivity but a poor specificity. However, positron emission tomography with 18F-2-deoxyglucose (FDG-PET) can offer superior spatial resolution and improved specificity. We attempted to evaluate the usefulness of FDG-PET for detecting bone metastases in breast cancer and to compare FDG-PET results with bone scan findings. Patients. The study group comprised 48 patients with biopsy-proven breast cancer and suspected of having bone metastases who underwent bone scan and FDG-PET to detect the bone metastases. The final diagnosis of bone metastases was established by operative, histopathological findings or during a clinical follow-up longer than 1 year by additional radiographs or following FDG-PET/bone scan findings showing progressive widespread bone lesions. Results. A total of 127 bone lesions including 105 metastatic and 22 benign bone lesions found by either FDG-PET or bone scan were evaluated. Using FDG-PET, 100 metastatic and 20 benign bone lesions were accurately diagnosed, and using bone scan 98 metastatic and 2 benign bone lesions were accurately diagnosed. The diagnostic sensitivity and accuracy of FDG-PET were 95.2% and 94.5%, and of bone scan were 93.3% and 78.7%, respectively. Conclusions. Our findings suggest that FDG-PET shows a similar sensitivity and a better accuracy than bone scan for detecting bone metastases in patients with breast cancer.
- 1 June 2002
- Published by Springer Nature in Journal of Cancer Research and Clinical Oncology
- Vol. 128 (6) , 325-328
Comparing whole body 18 F-2-deoxyglucose positron emission tomography and technetium-99m methylene diphosphonate bone scan to detect bone metastases in patients with breast cancer
Purpose. At present, bone metastases are usually assessed using conventional technetium-99m methylene diphosphonate whole-body bone scan, which has a high sensitivity but a poor specificity. However, positron emission tomography with 18F-2-deoxyglucose (FDG-PET) can offer superior spatial resolution and improved specificity. We attempted to evaluate the usefulness of FDG-PET for detecting bone metastases in breast cancer and to compare FDG-PET results with bone scan findings. Patients. The study group comprised 48 patients with biopsy-proven breast cancer and suspected of having bone metastases who underwent bone scan and FDG-PET to detect the bone metastases. The final diagnosis of bone metastases was established by operative, histopathological findings or during a clinical follow-up longer than 1 year by additional radiographs or following FDG-PET/bone scan findings showing progressive widespread bone lesions. Results. A total of 127 bone lesions including 105 metastatic and 22 benign bone lesions found by either FDG-PET or bone scan were evaluated. Using FDG-PET, 100 metastatic and 20 benign bone lesions were accurately diagnosed, and using bone scan 98 metastatic and 2 benign bone lesions were accurately diagnosed. The diagnostic sensitivity and accuracy of FDG-PET were 95.2% and 94.5%, and of bone scan were 93.3% and 78.7%, respectively. Conclusions. Our findings suggest that FDG-PET shows a similar sensitivity and a better accuracy than bone scan for detecting bone metastases in patients with breast cancer.