Mihrican Muti
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mihrican Muti has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
Kübra Gençdağ
Adnan Menderes University, Faculty of Arts and Sciences, Chemistry Department, 09010 Aydın, Turkey tel.: +90-256-218 2000, ext. 2209; fax:+ 90-256-213 5379; tel.: +90-256-218 2000, ext. 1898; fax: +90-256-213 5379
3 shared publications- A. Ersin Karagözler
Aydin Adnan Menderes University
2 shared publications Alican Aslan
2 shared publicationsFatma Merve Nacak
Adnan Menderes University, Faculty of Arts and Sciences, Chemistry Department, 09010 Aydın, Turkey tel.: +90-256-218 2000, ext. 2209; fax:+ 90-256-213 5379; tel.: +90-256-218 2000, ext. 1898; fax: +90-256-213 5379
2 shared publications- Mert Soysal
Aydın Adnan Menderes Üniversitesi
2 shared publications Merve Muti
Adnan Menderes University, Faculty of Arts and Sciences, Department of Chemistry, 09010 Aydın, Turkey; Adnan Menderes University, Söke Vocational School, Mechatronics Program, 09200 Aydın, Turkey
2 shared publications
Latest Publications
- 31 July 2018
- Published by Pleiades Publishing Ltd in Journal of Analytical Chemistry
- Vol. 73 (8) , 809-816
Nanosensing Platform for the Electrochemical Determination of Dopamine
Disposable, selective and low cost carbon nanotubes modified electrodes were fabricated for the electrochemical detection of dopamine (DA). An almost 4-fold increase in the dopamine oxidation...
- 31 July 2018
- Published by Pleiades Publishing Ltd in Journal of Analytical Chemistry
- Vol. 73 (8) , 809-816
Nanosensing Platform for the Electrochemical Determination of Dopamine
Disposable, selective and low cost carbon nanotubes modified electrodes were fabricated for the electrochemical detection of dopamine (DA). An almost 4-fold increase in the dopamine oxidation...
- 27 June 2017
- Published by Wiley in Electroanalysis
- Vol. 29 (10) , 2208-2216
Electrochemical Determination of Label Free BRCA Hybridization by Single Use Antioxidant Modified Electrode
A novel DNA probe based on caffeic acid modified disposable pencil graphite electrodes were developed for the first time for the electrochemical determination of breast cancer gene sequence (BRCA) hybridization. Amino‐linked BRCA probe highly immobilized onto the caffeic acid modified electrode by means of the interaction between the amino group of BRCA probe and the carboxyl group of caffeic acid compared to the bare electrode. 44 % signal enhancement in guanine oxidation signal was measured by caffeic acid modified electrode. Besides, these probes exhibited high selectivity towards its complementary DNA sequences (target). Hybridization between probe and target (BRCA1) was studied to evaluate the selectivity of the probes for complementary, non‐complementary and mismatch sequences. The selectivity was also tested in the presence of mixture containing the target and one base mismatch BRCA sequences in the same ratio (1 : 1). It can be said this probe can select its complementary from the mixture.
- 27 June 2017
- Published by Wiley in Electroanalysis
- Vol. 29 (10) , 2208-2216
Electrochemical Determination of Label Free BRCA Hybridization by Single Use Antioxidant Modified Electrode
A novel DNA probe based on caffeic acid modified disposable pencil graphite electrodes were developed for the first time for the electrochemical determination of breast cancer gene sequence (BRCA) hybridization. Amino‐linked BRCA probe highly immobilized onto the caffeic acid modified electrode by means of the interaction between the amino group of BRCA probe and the carboxyl group of caffeic acid compared to the bare electrode. 44 % signal enhancement in guanine oxidation signal was measured by caffeic acid modified electrode. Besides, these probes exhibited high selectivity towards its complementary DNA sequences (target). Hybridization between probe and target (BRCA1) was studied to evaluate the selectivity of the probes for complementary, non‐complementary and mismatch sequences. The selectivity was also tested in the presence of mixture containing the target and one base mismatch BRCA sequences in the same ratio (1 : 1). It can be said this probe can select its complementary from the mixture.
- 5 March 2015
- Published by Wiley in Electroanalysis
- Vol. 27 (6) , 1368-1377
A Novel DNA Probe Based on Molecularly Imprinted Polymer Modified Electrode for the Electrochemical Monitoring of DNA
A DNA probe that was based on methylene blue (MB) imprinted polyvinyl pyridine polymer (MIP) modified carbon paste electrodes were developed for the first time for electrochemical monitoring of DNA. Probes were built up by adsorbing MB onto modified electrodes prior to DNA immobilization. It was shown that DNA strongly immobilizes on MIP modified electrodes when MB was adsorbed in advance of DNA immobilization. The performance of the MB imprinted polymer modified carbon paste electrodes (MIP‐CPE) to rebind the template molecule (MB) were compared to those of control polymer modified (non‐imprinted polymer NIP‐CPE) and bare (CPE) electrodes. Electrochemical signal resulting from the oxidation of guanine moiety of the immobilized probe DNA was high enough on the constructed platform, implicating that probes of this kind could be favorably used for DNA analysis. These probes exhibited high selectivity for its complementary DNA sequences (target). HBV‐DNA hybridization was studied to evaluate the selectivity of the probes for complementary, non‐complementary and mismatch sequences. The detection limit of the probe for the target DNA was 8.72 µg/mL (1.38 µM), which was better than those attained by some earlier DNA sensor studies.
- 5 March 2015
- Published by Wiley in Electroanalysis
- Vol. 27 (6) , 1368-1377
A Novel DNA Probe Based on Molecularly Imprinted Polymer Modified Electrode for the Electrochemical Monitoring of DNA
A DNA probe that was based on methylene blue (MB) imprinted polyvinyl pyridine polymer (MIP) modified carbon paste electrodes were developed for the first time for electrochemical monitoring of DNA. Probes were built up by adsorbing MB onto modified electrodes prior to DNA immobilization. It was shown that DNA strongly immobilizes on MIP modified electrodes when MB was adsorbed in advance of DNA immobilization. The performance of the MB imprinted polymer modified carbon paste electrodes (MIP‐CPE) to rebind the template molecule (MB) were compared to those of control polymer modified (non‐imprinted polymer NIP‐CPE) and bare (CPE) electrodes. Electrochemical signal resulting from the oxidation of guanine moiety of the immobilized probe DNA was high enough on the constructed platform, implicating that probes of this kind could be favorably used for DNA analysis. These probes exhibited high selectivity for its complementary DNA sequences (target). HBV‐DNA hybridization was studied to evaluate the selectivity of the probes for complementary, non‐complementary and mismatch sequences. The detection limit of the probe for the target DNA was 8.72 µg/mL (1.38 µM), which was better than those attained by some earlier DNA sensor studies.
- 1 June 2013
- Published by Elsevier in Colloids and Surfaces B: Biointerfaces
- Vol. 106, 181-186
Electrochemical polymerized 5-amino-2-mercapto-1,3,4-thiadiazole modified single use sensors for detection of quercetin
- 1 June 2013
- Published by Elsevier in Colloids and Surfaces B: Biointerfaces
- Vol. 106, 181-186
Electrochemical polymerized 5-amino-2-mercapto-1,3,4-thiadiazole modified single use sensors for detection of quercetin
- 27 February 2013
- Published by Wiley in Electroanalysis
- Vol. 25 (5) , 1278-1285
A Novel and Selective Methylene Blue Imprinted Polymer Modified Carbon Paste Electrode
In this study, methylene blue (MB) imprinted microbeads were synthesized and characterized by Fourier transform infrared spectroscopy (FTIR) and scanning electron microscopy (SEM).Differential pulse voltammetric responses of carbon paste electrodes modified with MB imprinted polymer were used to evaluate the adsorption and selectivity features of the polymer. For selectivity studies two basic dyestuffs (thionine blue and toluidine blue) which have similar structure to MB were chosen. Comparison of the voltammetric responses obtained with pure carbon paste and carbon paste modified with either imprinted or nonimprinted polymer electrodes revealed that MB imprinted polymer presented a higher selectivity to the template molecule MB in contrast to structurally similar molecules, thionine blue and toluidine blue.
- 27 February 2013
- Published by Wiley in Electroanalysis
- Vol. 25 (5) , 1278-1285
A Novel and Selective Methylene Blue Imprinted Polymer Modified Carbon Paste Electrode
In this study, methylene blue (MB) imprinted microbeads were synthesized and characterized by Fourier transform infrared spectroscopy (FTIR) and scanning electron microscopy (SEM).Differential pulse voltammetric responses of carbon paste electrodes modified with MB imprinted polymer were used to evaluate the adsorption and selectivity features of the polymer. For selectivity studies two basic dyestuffs (thionine blue and toluidine blue) which have similar structure to MB were chosen. Comparison of the voltammetric responses obtained with pure carbon paste and carbon paste modified with either imprinted or nonimprinted polymer electrodes revealed that MB imprinted polymer presented a higher selectivity to the template molecule MB in contrast to structurally similar molecules, thionine blue and toluidine blue.