Yizhao Liao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yizhao Liao has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Wenbin Xue
Beijing Normal University
2 shared publications Chi Xu
Key Laboratory of Beam Technology of Ministry of Education, College of Nuclear Science and Technology, Beijing Normal University 1 , Beijing 100875, China
1 shared publication- Chi Xu
Beijing Normal University
1 shared publication - Chuanli Gao
Key Laboratory of Beam Technology of Ministry of Education, College of Nuclear Science and Technology, Beijing Normal University 1 , Beijing 100875, China
1 shared publication Jiancheng Du
Key Laboratory of Beam Technology of Ministry of Education, College of Nuclear Science and Technology, Beijing Normal University 1 , Beijing 100875, China
1 shared publication- Jiancheng Du
Key Laboratory of Beam Technology of Ministry of Education, School of Physics and Astronomy, Beijing Normal University, Beijing 100875, P. R. China
1 shared publication
Latest Publications
- 23 November 2026
- Published by World Scientific Pub Co Pte Ltd in International Journal of Modern Physics B
Optical, sound and vibration monitoring of plasma electrolytic oxidation process on 15% SiC p /2009 aluminum matrix composite under different voltages
The micro-discharge evolution during bipolar pulsed plasma electrolytic oxidation (PEO) on 15[Formula: see text]vol.% SiC p /2009 aluminum matrix composite was monitored by optical emission spectroscopy (OES), sound and vibration nondestructive measurement techniques. OES was detected from a glass window outside the electrolytic bath; meanwhile, the hydrophone, microphone and accelerator were fixed inside the electrolyte, above the electrolyte and on the sample surface exposed in atmosphere environment, respectively, to monitor underwater sound, airborne sound and sample vibration signals during the PEO treatment, meanwhile, their three-dimensional time–frequency spectra are evaluated. The variations of optical, airborne sound, underwater sound and sample vibration signals under different voltages were analyzed. It was found that the illumination, spectral line intensity of OES and underwater and airborne sound signals were related to the size and density of all discharge sparks, while the intensity of vibration signals mainly depended on the size of the strong sparks. Moreover, the spike peaks on the intensity curves of sound and vibration signals were also related to strong discharge sparks. With the increase of applied voltage, the intensities of micro-discharges increased, and the frequency response intensities of the sound signal within 20[Formula: see text]kHz and the vibration signal within 10[Formula: see text]kHz were enhanced. Sound and vibration signals were mainly attributed to the evolution of bubbles from the plasma discharge. These results confirmed that the PEO discharge process can be effectively monitored by optical, sound and vibration measurement techniques.
- 23 November 2026
- Published by World Scientific Pub Co Pte Ltd in International Journal of Modern Physics B
Optical, sound and vibration monitoring of plasma electrolytic oxidation process on 15% SiC p /2009 aluminum matrix composite under different voltages
The micro-discharge evolution during bipolar pulsed plasma electrolytic oxidation (PEO) on 15[Formula: see text]vol.% SiC p /2009 aluminum matrix composite was monitored by optical emission spectroscopy (OES), sound and vibration nondestructive measurement techniques. OES was detected from a glass window outside the electrolytic bath; meanwhile, the hydrophone, microphone and accelerator were fixed inside the electrolyte, above the electrolyte and on the sample surface exposed in atmosphere environment, respectively, to monitor underwater sound, airborne sound and sample vibration signals during the PEO treatment, meanwhile, their three-dimensional time–frequency spectra are evaluated. The variations of optical, airborne sound, underwater sound and sample vibration signals under different voltages were analyzed. It was found that the illumination, spectral line intensity of OES and underwater and airborne sound signals were related to the size and density of all discharge sparks, while the intensity of vibration signals mainly depended on the size of the strong sparks. Moreover, the spike peaks on the intensity curves of sound and vibration signals were also related to strong discharge sparks. With the increase of applied voltage, the intensities of micro-discharges increased, and the frequency response intensities of the sound signal within 20[Formula: see text]kHz and the vibration signal within 10[Formula: see text]kHz were enhanced. Sound and vibration signals were mainly attributed to the evolution of bubbles from the plasma discharge. These results confirmed that the PEO discharge process can be effectively monitored by optical, sound and vibration measurement techniques.
- Open Access
- 1 June 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (6)
In situ monitoring of initial plasma electrolytic oxidation process on 60 vol. % SiCp/2009 aluminum matrix composite by sound and vibration measurement techniques
The initial discharge process of plasma electrolytic oxidation (PEO) on the 60 vol. % SiCP/2009 aluminum matrix composite in silicate solution was in situ monitored by sound and vibration measurement techniques. The underwater sound, airborne sound, and sample vibration signals were detected in the initial 120 s of the PEO process, and their generation mechanism was discussed. In terms of waveforms and spectrograms of the sound and vibration signals, the initial PEO process can be divided into five stages: conventional anodizing stage (I), glow discharge stage (Ⅱ), tiny spark discharge stage (Ⅲ), large spark discharge stage (Ⅳ), and strong spark discharge stage (Ⅴ). The sound and vibration signals during the PEO process are attributed to the evolution of bubbles, which are from the plasma discharge, electrochemical reactions, and vaporization of electrolyte under Joule heat. In stage I, these signals completely come from the bubbles produced by the evaporative electrolyte and electrochemical reactions. In stages Ⅱ–Ⅴ, the bubbles from the plasma discharge gradually become the main source of these signals with increasing discharge intensity. In addition, the spike peaks on the waveforms of these signals at stage Ⅴ are related to the strong discharge sparks. These results demonstrate that sound and vibration measurement techniques can effectively monitor the PEO discharge process.
- 1 June 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (6)
Open AccessIn situ monitoring of initial plasma electrolytic oxidation process on 60 vol. % SiCp/2009 aluminum matrix composite by sound and vibration measurement techniques
The initial discharge process of plasma electrolytic oxidation (PEO) on the 60 vol. % SiCP/2009 aluminum matrix composite in silicate solution was in situ monitored by sound and vibration measurement techniques. The underwater sound, airborne sound, and sample vibration signals were detected in the initial 120 s of the PEO process, and their generation mechanism was discussed. In terms of waveforms and spectrograms of the sound and vibration signals, the initial PEO process can be divided into five stages: conventional anodizing stage (I), glow discharge stage (Ⅱ), tiny spark discharge stage (Ⅲ), large spark discharge stage (Ⅳ), and strong spark discharge stage (Ⅴ). The sound and vibration signals during the PEO process are attributed to the evolution of bubbles, which are from the plasma discharge, electrochemical reactions, and vaporization of electrolyte under Joule heat. In stage I, these signals completely come from the bubbles produced by the evaporative electrolyte and electrochemical reactions. In stages Ⅱ–Ⅴ, the bubbles from the plasma discharge gradually become the main source of these signals with increasing discharge intensity. In addition, the spike peaks on the waveforms of these signals at stage Ⅴ are related to the strong discharge sparks. These results demonstrate that sound and vibration measurement techniques can effectively monitor the PEO discharge process.