Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Husam Abed Alfattah has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Solvent bar microextraction based on using deep eutectic solvent and multivariate optimization for simultaneous determination of antidepressant and antiepileptic drugs in biological fluids

    by Nabil N. Al-Hashimi, Amjad H. El-Sheikh, Alaa S. Alfawaz, Khaleel I. Assaf, Husam Abed Alfattah, Khairi M. Fahelelbom

    Monitoring medications in biological fluids is an essential aspect of patient care, particularly in cases of altered mental status where accurate diagnosis, effective treatment, and even forensic examinations are crucial. In this study, a new approach combining hydrophobic-deep-eutectic and solvent-bar-microextraction (HDE-SBME) followed by a high-performance liquid chromatography-diode array detector (HPLC-DAD) was developed for the simultaneous determination of desipramine, clomipramine, as antidepressant and carbamazepine as antiepileptic agents in untreated human urine and plasma samples. The HDE solvents, synthesized using various ratios of menthol and fatty acids, were utilized in the SBME setups. Computational methods were employed to predict the structure and modes of interaction between HDE and the chosen analytes. Central composite design methodology (CCD) was used for multivariate optimization of the effects of different parameters influencing the extraction efficiency of the proposed method. Under optimized experimental conditions, the calibration graph of the spiked selected drugs in urine and plasma samples demonstrated excellent linearity (R2 ≥ 0.994), with limits of detection/quantification below 0.60/2.02 μg L−1. The extraction recoveries achieved were 88–97%, and the repeatability/reproducibility (RSD%, n = 5) was less than 6.12/7.57. The proposed method was successfully applied to determine selected drugs in patients' urine and plasma samples. The proposed method detects three drugs in patients' urine and plasma samples without using toxic volatile organic solvents. The proposed microextraction technique exhibited a confident sensitivity, feasible operation, and simplicity compared with other published methods. Thus, it can be considered a promising method for monitoring the therapeutic levels of specific antidepressant and antiepileptic drugs in urine and plasma samples.


  • Open Access

    A new hydrophobic deep eutectic solvent composed of menthol and tris(2-ethylhexyl) phosphate for solvent bar microextraction of parabens from biological fluids

    by Nabil N. Al-Hashimi, Husam Abed Alfattah, Khaleel I. Assaf, Asma A. Fakhoury, Saja H. Hamed, Amjad H. El-Sheikh, Khairi M. Fahelelbom


  • Open Access

    Solvent Bar Microextraction Method Based on a Natural Deep Eutectic Solvent and Multivariate Optimization for Determination of Steroid Hormones in Urine and Water

    by Nabil N. Al-Hashimi, Husam Abed Alfattah, Musa I. El-Barghouthi, Amjad H. El-Sheikh, Hanan M. Ale-Nezi, Mahmoud S. Sunjuk, Khairi M. Fahelelbom

    Steroid hormones may pose potential risks to both human health and wildlife, primarily through the consumption of medication or polluted food and water; efforts are being made to monitor their levels in the human body and regulate and minimize their releases to the environment. In this study, a simple and environmentally friendly sample preparation method was developed to simultaneously determine three steroid hormones in urine and water samples. A monoterpene (menthol) and a fatty acid (lauric acid) were combined in various ratios to form a hydrophobic deep eutectic (HDE) solvent as an extraction solvent in solvent bar microextraction (SBME). Using a univariate strategy, a menthol-to-lauric acid HDE ratio of 4:1 and a pH 7 of the sample solution resulted in the highest extraction efficiency (EE%) of the selected steroids. The computational methods have been employed to predict a 4:1 HDE interaction with chosen steroids. Additionally, chemometric approaches suggested that the optimal extraction conditions involved HDEs as extract solvent confined within three SBME devices directly immersed into a 20 mL sample solution with a 30 min extraction time, followed by ultrasonication within 200 μL of elution solvent for a 5 min elution time. Under optimized conditions, the method calibration graph for the spiked selected steroids in the water and urine samples showed good linearity with R2 ≥ 0.994 with limits of detection/quantification lower than 0.40/1.35 μg L−1 and repeatability/reproducibility (RSD%, n = 5) lower than 5.09/7.11. The developed method allows a safe, rapid, and reliable analysis of three steroid hormones in human urine and water samples without using toxic volatile organic solvents.


  • Open Access

    Hydrophobic natural deep eutectic-solvent bar microextraction combined with HPLC-DAD for determination of urinary 1-hydroxypyrene of smokers

    by Nabil N. Al-Hashimi, Husam Abed Alfattah, Amjad H. El-Sheikh, Jafar I. Abdelghani, Abdelrahim M.A. Alqudah, Alaa S. Alfawaz