Jukka Yrjölä
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Jukka Yrjölä has a total of 2 co-authors. Here are the top co-authors by number of shared publications:
Janne Paavilainen
Satakunta Polytechnic, Tekniikantie 2, FIN‐28600 Pori, Finland
2 shared publicationsMatti Sillanpää
Thermia Ltd., P.O. Box 59, FIN‐43101 Saarijärvi, Finland
1 shared publication
Latest Publications
- 10 October 2006
- Published by Hindawi Limited in International Journal of Energy Research
- Vol. 30 (12) , 939-953
Modelling and experimental studies on heat transfer in the convection section of a biomass boiler
- 10 October 2006
- Published by Hindawi Limited in International Journal of Energy Research
- Vol. 30 (12) , 939-953
Modelling and experimental studies on heat transfer in the convection section of a biomass boiler
- 22 April 2004
- Published by Hindawi Limited in International Journal of Energy Research
- Vol. 28 (6) , 473-494
Modelling and analyses of heat exchangers in a biomass boiler plant
A boiler plant is presented, in which the fuel is dried before combustion in a silo with air. The drying air is heated in a recuperative heat exchanger by the heat of flue gases. Hot air is then blown through the bed of fuel in the drying silo, while the fuel dries and the air cools down and becomes humidified. Heat of the moist exhaust air of the silo is recovered for the drying air and combustion air by a recuperative heat exchanger. Modelling of the thermal behaviour of the plant helps in understanding complex interdependencies of the two heat exchangers, the boiler and the dryer. The models of the heat exchangers and applications in analysing the boiler system are described in this paper. Calculating the combinations of extreme operational conditions gives the input data needed in comparing different types of heat exchangers, dimensioning the heat transfer area, choosing the control strategy and selecting the operating parameters and set-values of the control system. Results of verification measurements and practical operation at a 40 kWth pilot plant and a 500 kWth demonstration plant are also discussed. Using engineering correlation formulas for heat and mass transfer, an adequate accuracy between the model and the measurements was achieved. Fouling was detected to be a major problem with the flue gas heat exchanger. However, in absence of condensation, the increase of a fouling layer with respect to time was observed to be low. Fouling was also a problem with the drying exhaust gas heat exchanger, but after the installation of a simple dust collector, a reasonable cleaning period was achieved. A mixed-flow configuration was found to be the most appropriate for the flue gas heat exchanger. In order to avoid condensation of the flue gas the drying exhaust gas heat exchanger is indispensable in Finnish climate in the considered system. In addition to this, it decreases the need of fuel. A parallel-flow type was found the most appropriate as the drying exhaust gas heat exchanger. Copyright © 2004 John Wiley & Sons, Ltd.
- 22 April 2004
- Published by Hindawi Limited in International Journal of Energy Research
- Vol. 28 (6) , 473-494
Modelling and analyses of heat exchangers in a biomass boiler plant
A boiler plant is presented, in which the fuel is dried before combustion in a silo with air. The drying air is heated in a recuperative heat exchanger by the heat of flue gases. Hot air is then blown through the bed of fuel in the drying silo, while the fuel dries and the air cools down and becomes humidified. Heat of the moist exhaust air of the silo is recovered for the drying air and combustion air by a recuperative heat exchanger. Modelling of the thermal behaviour of the plant helps in understanding complex interdependencies of the two heat exchangers, the boiler and the dryer. The models of the heat exchangers and applications in analysing the boiler system are described in this paper. Calculating the combinations of extreme operational conditions gives the input data needed in comparing different types of heat exchangers, dimensioning the heat transfer area, choosing the control strategy and selecting the operating parameters and set-values of the control system. Results of verification measurements and practical operation at a 40 kWth pilot plant and a 500 kWth demonstration plant are also discussed. Using engineering correlation formulas for heat and mass transfer, an adequate accuracy between the model and the measurements was achieved. Fouling was detected to be a major problem with the flue gas heat exchanger. However, in absence of condensation, the increase of a fouling layer with respect to time was observed to be low. Fouling was also a problem with the drying exhaust gas heat exchanger, but after the installation of a simple dust collector, a reasonable cleaning period was achieved. A mixed-flow configuration was found to be the most appropriate for the flue gas heat exchanger. In order to avoid condensation of the flue gas the drying exhaust gas heat exchanger is indispensable in Finnish climate in the considered system. In addition to this, it decreases the need of fuel. A parallel-flow type was found the most appropriate as the drying exhaust gas heat exchanger. Copyright © 2004 John Wiley & Sons, Ltd.