Antonio Glenn
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Antonio Glenn has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Shwetak Patel
University of Washington, Seattle, USA
3 shared publications - Shyamnath Gollakota
University of Washington, Seattle, USA
2 shared publications - William A. Grissom
Department of Biomedical Engineering Case Western Reserve University Cleveland Ohio USA
2 shared publications - Aditya Bagaria
University of Washington, United States
1 shared publication - Bandhav Veluri
Paul G. Allen Center for Computer Science & Engineering, University of Washington, United States
1 shared publication - Christopher E. Vaughn
Department of Biomedical Engineering Case Western Reserve University Cleveland Ohio USA
1 shared publication
Latest Publications
- 6 October 2026
- Published by Wiley in NMR in Biomedicine
- Vol. 39 (11)
Low‐Cost, Computer‐Free Spin Echo Generator Board
A Spin Echo Generator Board has been designed as an affordable tool for MR system quality assurance, demonstration, and education. Inspired by earlier work on inexpensive spin echo generator circuit boards, the board uses low‐cost digital timing circuits for pulse generation and mixers for RF pulse gating, without requiring a computer. It produces a simple rectangular excitation pulse followed by a refocusing pulse, with user‐adjustable pulse widths, TE, and TR delays. The board features an integrated T/R switch, pre‐amplifier, and an onboard 9‐V battery holder for standalone operation. External requirements include only a synthesizer, RF power amplifier, oscilloscope for display, and a tuned RF coil placed within a magnet. The hands‐on platform and real‐time feedback support practical applications, such as verifying signal generation and coil performance. In an educational setting, the board enables students to explore how variations in timing parameters influence MR signal behavior. It provides a transparent learning environment in which students can investigate fundamental MRI concepts, including flip angle, resonance, and T 2 relaxation, through direct experimentation. Functionality is demonstrated on a 0.5‐T tabletop magnet and 0.1‐T whole‐body MRI scanner.
- 6 October 2026
- Published by Wiley in NMR in Biomedicine
- Vol. 39 (11)
Low‐Cost, Computer‐Free Spin Echo Generator Board
A Spin Echo Generator Board has been designed as an affordable tool for MR system quality assurance, demonstration, and education. Inspired by earlier work on inexpensive spin echo generator circuit boards, the board uses low‐cost digital timing circuits for pulse generation and mixers for RF pulse gating, without requiring a computer. It produces a simple rectangular excitation pulse followed by a refocusing pulse, with user‐adjustable pulse widths, TE, and TR delays. The board features an integrated T/R switch, pre‐amplifier, and an onboard 9‐V battery holder for standalone operation. External requirements include only a synthesizer, RF power amplifier, oscilloscope for display, and a tuned RF coil placed within a magnet. The hands‐on platform and real‐time feedback support practical applications, such as verifying signal generation and coil performance. In an educational setting, the board enables students to explore how variations in timing parameters influence MR signal behavior. It provides a transparent learning environment in which students can investigate fundamental MRI concepts, including flip angle, resonance, and T 2 relaxation, through direct experimentation. Functionality is demonstrated on a 0.5‐T tabletop magnet and 0.1‐T whole‐body MRI scanner.
- Open Access
- 18 May 2026
- Published by Springer Nature in Communications Physics
Frequency-encoded magnetic resonance imaging with dynamic radio frequency field gradients
Magnetic Resonance Imaging is the gold standard for soft tissue diagnostic imaging but relies on expensive, failure-prone, and loud magnetic field gradients for spatial encoding. Radiofrequency field gradients are a promising alternative, yet they have never achieved frequency encoding, the technique that allows an image to be acquired continuously in milliseconds and without which scan times would increase by orders of magnitude. Here we show that the Bloch-Siegert shift can apply a spatial frequency gradient simultaneously with signal recording, without displacing magnetization from the plane where it generates signal. Combined with an injection transformer based simultaneous transmit-and-receive system that prevents the strong encoding field from overwhelming the weak tissue signal, this approach produces images on a 47.5 mT low-field scanner equivalent in quality to those from conventional gradient encoding. This work enables smaller, quieter, and less expensive scanners without compromising scan time or diagnostic image quality, with particular promise for expanding access to imaging in resource-limited settings.
- 18 May 2026
- Published by Springer Nature in Communications Physics
Open AccessFrequency-encoded magnetic resonance imaging with dynamic radio frequency field gradients
Magnetic Resonance Imaging is the gold standard for soft tissue diagnostic imaging but relies on expensive, failure-prone, and loud magnetic field gradients for spatial encoding. Radiofrequency field gradients are a promising alternative, yet they have never achieved frequency encoding, the technique that allows an image to be acquired continuously in milliseconds and without which scan times would increase by orders of magnitude. Here we show that the Bloch-Siegert shift can apply a spatial frequency gradient simultaneously with signal recording, without displacing magnetization from the plane where it generates signal. Combined with an injection transformer based simultaneous transmit-and-receive system that prevents the strong encoding field from overwhelming the weak tissue signal, this approach produces images on a 47.5 mT low-field scanner equivalent in quality to those from conventional gradient encoding. This work enables smaller, quieter, and less expensive scanners without compromising scan time or diagnostic image quality, with particular promise for expanding access to imaging in resource-limited settings.
- Open Access
- 25 April 2025
- Published by Association for Computing Machinery (ACM)
- p. 1-14
ECG Necklace: Low-power Wireless Necklace for Continuous ECG monitoring
- 25 April 2025
- Published by Association for Computing Machinery (ACM)
- p. 1-14
Open AccessECG Necklace: Low-power Wireless Necklace for Continuous ECG monitoring
- Open Access
- 11 October 2024
- Published by Association for Computing Machinery (ACM)
- p. 1-16
IRIS: Wireless ring for vision-based smart home interaction
Integrating cameras into wireless smart rings has been challenging due to size and power constraints. We introduce IRIS, the first wireless vision-enabled smart ring system for smart home interactions. Equipped with a camera, Bluetooth radio, inertial measurement unit (IMU), and an onboard battery, IRIS meets the small size, weight, and power (SWaP) requirements for ring devices. IRIS is context-aware, adapting its gesture set to the detected device, and can last for 16-24 hours on a single charge. IRIS leverages the scene semantics to achieve instance-level device recognition. In a study involving 23 participants, IRIS consistently outpaced voice commands, with a higher proportion of participants expressing a preference for IRIS over voice commands regarding toggling a device’s state, granular control, and social acceptability. Our work pushes the boundary of what is possible with ring form-factor devices, addressing system challenges and opening up novel interaction capabilities.
- 11 October 2024
- Published by Association for Computing Machinery (ACM)
- p. 1-16
Open AccessIRIS: Wireless ring for vision-based smart home interaction
Integrating cameras into wireless smart rings has been challenging due to size and power constraints. We introduce IRIS, the first wireless vision-enabled smart ring system for smart home interactions. Equipped with a camera, Bluetooth radio, inertial measurement unit (IMU), and an onboard battery, IRIS meets the small size, weight, and power (SWaP) requirements for ring devices. IRIS is context-aware, adapting its gesture set to the detected device, and can last for 16-24 hours on a single charge. IRIS leverages the scene semantics to achieve instance-level device recognition. In a study involving 23 participants, IRIS consistently outpaced voice commands, with a higher proportion of participants expressing a preference for IRIS over voice commands regarding toggling a device’s state, granular control, and social acceptability. Our work pushes the boundary of what is possible with ring form-factor devices, addressing system challenges and opening up novel interaction capabilities.
- Open Access
- 18 June 2023
- Published by Association for Computing Machinery (ACM)
- p. 84-95
Wireless earbuds for low-cost hearing screening
We present the first wireless earbud hardware that can perform hearing screening by detecting otoacoustic emissions. The conventional wisdom has been that detecting otoacoustic emissions, which are the faint sounds generated by the cochlea, requires sensitive and expensive acoustic hardware. Thus, medical devices for hearing screening cost thousands of dollars and are inaccessible in low and middle income countries. We show that by designing wireless ear-buds using low-cost acoustic hardware and combining them with wireless sensing algorithms, we can reliably identify otoacoustic emissions and perform hearing screening. Our algorithms combine frequency modulated chirps with wideband pulses emitted from a low-cost speaker to reliably separate otoacoustic emissions from in-ear reflections and echoes. We conducted a clinical study with 50 ears across two healthcare sites. Our study shows that the low-cost earbuds detect hearing loss with 100% sensitivity and 89.7% specificity, which is comparable to the performance of a $8000 medical device. By developing low-cost and open-source wearable technology, our work may help address global health inequities in hearing screening by democratizing these medical devices. Open-source hardware and code can be found here: https://github.com/uw-x/OAEbuds
- 18 June 2023
- Published by Association for Computing Machinery (ACM)
- p. 84-95
Open AccessWireless earbuds for low-cost hearing screening
We present the first wireless earbud hardware that can perform hearing screening by detecting otoacoustic emissions. The conventional wisdom has been that detecting otoacoustic emissions, which are the faint sounds generated by the cochlea, requires sensitive and expensive acoustic hardware. Thus, medical devices for hearing screening cost thousands of dollars and are inaccessible in low and middle income countries. We show that by designing wireless ear-buds using low-cost acoustic hardware and combining them with wireless sensing algorithms, we can reliably identify otoacoustic emissions and perform hearing screening. Our algorithms combine frequency modulated chirps with wideband pulses emitted from a low-cost speaker to reliably separate otoacoustic emissions from in-ear reflections and echoes. We conducted a clinical study with 50 ears across two healthcare sites. Our study shows that the low-cost earbuds detect hearing loss with 100% sensitivity and 89.7% specificity, which is comparable to the performance of a $8000 medical device. By developing low-cost and open-source wearable technology, our work may help address global health inequities in hearing screening by democratizing these medical devices. Open-source hardware and code can be found here: https://github.com/uw-x/OAEbuds