Ariane Bollack
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Ariane Bollack has a total of 147 co-authors. Here are the top co-authors by number of shared publications:
Gill Farrar
GE Healthcare Amersham UK
9 shared publications- Frederik Barkhof
Amsterdam UMC, Location VUmc
7 shared publications - Lyduine E. Collij
Department of Radiology and Nuclear Medicine, UMC Vrije Universiteit Amsterdam, Amsterdam, The Netherlands
6 shared publications Christopher Buckley
GE HealthCare, Chalfont St Giles, Buckinghamshire UK
5 shared publications- David Marshall Cash
Dementia Research Centre, Queen Square Institute of Neurology, University College London, London, UK
5 shared publications - Juan Domingo Gispert
Barcelonaβeta Brain Research Center (BBRC), Pasqual Maragall Foundation
5 shared publications
Latest Publications
- Open Access
- 23 June 2026
- Published by Wiley in Alzheimer's & Dementia
- Vol. 22 (6) , e71609
Cortical gray–white matter contrast alterations precede amyloid‐β positivity and macrostructural changes in older adults without dementia
INTRODUCTION: Early Alzheimer's disease (AD) involves subtle cortical changes that may precede atrophy. Magnetic resonance imaging (MRI) microstructural markers may detect earlier pathology than classical morphometry. METHODS: We analyzed cross‐sectional MRI and amyloid‐β (Aβ) positron emission tomography (PET) data from 1323 non‐demented AMYPAD participants. Cortical volume, thickness, gray–white matter contrast (GWC), and mean diffusivity (MD) were related to global Aβ burden and estimated time to Aβ‐positivity using regression, correlation, and change‐point analyses. RESULTS: Microstructural measures showed stronger age associations than macrostructural measures, whereas all measures were unaffected by apolipoprotein E ( APOE) ‐ε4 carriership. GWC and MD showed minimal overlap with volume and thickness. Higher Aβ burden was most strongly associated with reduced GWC and cortical thinning. Change‐point analyses showed GWC alterations preceded Aβ‐positivity by several years. DISCUSSION: Cortical microstructural MRI, particularly GWC, changes earlier than atrophy and may serve as an early in vivo marker of AD pathology.
- 23 June 2026
- Published by Wiley in Alzheimer's & Dementia
- Vol. 22 (6) , e71609
Open AccessCortical gray–white matter contrast alterations precede amyloid‐β positivity and macrostructural changes in older adults without dementia
INTRODUCTION: Early Alzheimer's disease (AD) involves subtle cortical changes that may precede atrophy. Magnetic resonance imaging (MRI) microstructural markers may detect earlier pathology than classical morphometry. METHODS: We analyzed cross‐sectional MRI and amyloid‐β (Aβ) positron emission tomography (PET) data from 1323 non‐demented AMYPAD participants. Cortical volume, thickness, gray–white matter contrast (GWC), and mean diffusivity (MD) were related to global Aβ burden and estimated time to Aβ‐positivity using regression, correlation, and change‐point analyses. RESULTS: Microstructural measures showed stronger age associations than macrostructural measures, whereas all measures were unaffected by apolipoprotein E ( APOE) ‐ε4 carriership. GWC and MD showed minimal overlap with volume and thickness. Higher Aβ burden was most strongly associated with reduced GWC and cortical thinning. Change‐point analyses showed GWC alterations preceded Aβ‐positivity by several years. DISCUSSION: Cortical microstructural MRI, particularly GWC, changes earlier than atrophy and may serve as an early in vivo marker of AD pathology.
- Open Access
MR-Guided PET Denoising and Resolution Enhancement Improves Visual Interpretation and Preserves Quantitative Behavior Across Amyloid Tracers
Background: Amyloid- β PET provides critical biomarker data for Alzheimer’s disease diagnosis and anti-amyloid therapy evaluation, yet low spatial resolution and partial volume effects result in decreased interpretability, particularly in cases with low or borderline cortical amyloid burden. While quantitative metrics (SUVr, Centiloid) aid in interpretation of amyloid burden, disagreement between visual reads and quantitative burden does occur, further blurring the line between positive or negative scans. We evaluated whether a vendor-neutral MR-guided PET denoising and resolution enhancement method (MRG) that uses Bowsher regularization improves image interpretability and reader performance while preserving established quantitative biomarkers across multiple amyloid tracers, leading to increased concordance among visual reads and quantitative metrics. Methods: Standard (STN) and MRG PET images were compared for four tracers ([ 18 F]AV-45 ([ 18 F]florbetapir, FBP), [ 18 F]florbetaben (FBB), [ 18 F]flutemetamol (FMM), and [ 11 C]Pittsburgh compound-B (PiB)) collectively from 24 MRI and 33 PET scanners. Quantitative equivalence was assessed by comparing Standardized Uptake Value ratio (SUVr) and Centiloid scores. In three of the four tracers (FBP, FBB, FMM), visual-quantitative concordance (AUC) and reader performance were evaluated in a blinded multi-reader study by four highly experienced brain PET readers who assessed image quality, artifact severity, reader confidence, and binary amyloid positivity. Results: Across all tracers, MRG preserved quantitative SUVr and Centiloid metrics relative to STN ( R 2 > 0.90 for all tracers) without introducing bias to the SUVr metric. Concordance between visual reads and quantitative burden measures significantly improved with MRG. In the multi-reader study, MRG resulted in significantly higher image quality, lower artifact burden, and greater reader confidence compared to STN ( p < 0.0001 ). Reader accuracy increased from 0.89 to 0.94, and the false-negative rate decreased from 0.08 to 0.04. Crucially, improvements in reader confidence, accuracy, and the reduction in false negative reads were most pronounced in cases with low amyloid burden near the threshold of visual positivity. Conclusions: MRG denoising and resolution enhancement improved perceived image quality, reader confidence, and accuracy for amyloid PET while preserving standard quantitative behavior across tracers. By improving cortical definition in visually challenging low-burden cases without disrupting established SUVr/Centiloid behavior, MRG may reduce visual-quantitative discordance and support more confident amyloid PET interpretation near the threshold of positivity.
Open AccessMR-Guided PET Denoising and Resolution Enhancement Improves Visual Interpretation and Preserves Quantitative Behavior Across Amyloid Tracers
Background: Amyloid- β PET provides critical biomarker data for Alzheimer’s disease diagnosis and anti-amyloid therapy evaluation, yet low spatial resolution and partial volume effects result in decreased interpretability, particularly in cases with low or borderline cortical amyloid burden. While quantitative metrics (SUVr, Centiloid) aid in interpretation of amyloid burden, disagreement between visual reads and quantitative burden does occur, further blurring the line between positive or negative scans. We evaluated whether a vendor-neutral MR-guided PET denoising and resolution enhancement method (MRG) that uses Bowsher regularization improves image interpretability and reader performance while preserving established quantitative biomarkers across multiple amyloid tracers, leading to increased concordance among visual reads and quantitative metrics. Methods: Standard (STN) and MRG PET images were compared for four tracers ([ 18 F]AV-45 ([ 18 F]florbetapir, FBP), [ 18 F]florbetaben (FBB), [ 18 F]flutemetamol (FMM), and [ 11 C]Pittsburgh compound-B (PiB)) collectively from 24 MRI and 33 PET scanners. Quantitative equivalence was assessed by comparing Standardized Uptake Value ratio (SUVr) and Centiloid scores. In three of the four tracers (FBP, FBB, FMM), visual-quantitative concordance (AUC) and reader performance were evaluated in a blinded multi-reader study by four highly experienced brain PET readers who assessed image quality, artifact severity, reader confidence, and binary amyloid positivity. Results: Across all tracers, MRG preserved quantitative SUVr and Centiloid metrics relative to STN ( R 2 > 0.90 for all tracers) without introducing bias to the SUVr metric. Concordance between visual reads and quantitative burden measures significantly improved with MRG. In the multi-reader study, MRG resulted in significantly higher image quality, lower artifact burden, and greater reader confidence compared to STN ( p < 0.0001 ). Reader accuracy increased from 0.89 to 0.94, and the false-negative rate decreased from 0.08 to 0.04. Crucially, improvements in reader confidence, accuracy, and the reduction in false negative reads were most pronounced in cases with low amyloid burden near the threshold of visual positivity. Conclusions: MRG denoising and resolution enhancement improved perceived image quality, reader confidence, and accuracy for amyloid PET while preserving standard quantitative behavior across tracers. By improving cortical definition in visually challenging low-burden cases without disrupting established SUVr/Centiloid behavior, MRG may reduce visual-quantitative discordance and support more confident amyloid PET interpretation near the threshold of positivity.
- Open Access
- 21 April 2026
- Published by Elsevier in Neuroimage: Reports
- Vol. 6 (2) , 100343
Comparability of Centiloid values from [18F]flutemetamol scans using seven commercial and research software
- 21 April 2026
- Published by Elsevier in Neuroimage: Reports
- Vol. 6 (2) , 100343
Open AccessComparability of Centiloid values from [18F]flutemetamol scans using seven commercial and research software
- Open Access
- 23 December 2025
- Published by Wiley in Alzheimer's & Dementia
- Vol. 21 (S8) , e110090
Interchangeability of Centiloid values from different research and commercial software using [ 18 F]flutemetamol PET images
Background: Amyloid PET quantification using the Centiloid (CL) metric is becoming more prevalent and may have a role in clinical decision‐making. But what is the intrinsic confidence interval around a given CL value? To what extent is a CL value from one pipeline equivalent to that from another? We systematically assessed repeatability, reproducibility, and reliability across seven CL quantification pipelines applied to 210 [ 18 F]flutemetamol scans. Method: Three datasets were used: (1) an AD test‐retest cohort ( N = 10x2); (2) an amnestic MCI cohort ( N = 80); (3) cases from the BioFINDER‐1 cohort enriched for amyloid loads around published positivity thresholds (0‐50CL) ( N = 110). Three regulatory‐approved software (cPET, MIMneuro, syngo . MI Neurology) and four research pipelines (CapAIBL, rPOP, Amypype, SPM8) were evaluated. Dataset 1 was used to assess within‐subject repeatability. Dataset 2 was used to assess reproducibility in terms of absolute agreement in continuous CL values. Datasets 2 and 3 were used to assess reliability for dichotomizing amyloid scans into positive and negative. The latter was performed for three thresholds of 11, 25 and 37 CL. Result: The test‐retest analysis revealed absolute biases 92% for scans across a wide range of CL values, but the percentage was lower for scans with amyloid loads closer to the range of typical positivity thresholds. Uncertainty estimates should always be considered when interpreting results.
- 23 December 2025
- Published by Wiley in Alzheimer's & Dementia
- Vol. 21 (S8) , e110090
Open AccessInterchangeability of Centiloid values from different research and commercial software using [ 18 F]flutemetamol PET images
Background: Amyloid PET quantification using the Centiloid (CL) metric is becoming more prevalent and may have a role in clinical decision‐making. But what is the intrinsic confidence interval around a given CL value? To what extent is a CL value from one pipeline equivalent to that from another? We systematically assessed repeatability, reproducibility, and reliability across seven CL quantification pipelines applied to 210 [ 18 F]flutemetamol scans. Method: Three datasets were used: (1) an AD test‐retest cohort ( N = 10x2); (2) an amnestic MCI cohort ( N = 80); (3) cases from the BioFINDER‐1 cohort enriched for amyloid loads around published positivity thresholds (0‐50CL) ( N = 110). Three regulatory‐approved software (cPET, MIMneuro, syngo . MI Neurology) and four research pipelines (CapAIBL, rPOP, Amypype, SPM8) were evaluated. Dataset 1 was used to assess within‐subject repeatability. Dataset 2 was used to assess reproducibility in terms of absolute agreement in continuous CL values. Datasets 2 and 3 were used to assess reliability for dichotomizing amyloid scans into positive and negative. The latter was performed for three thresholds of 11, 25 and 37 CL. Result: The test‐retest analysis revealed absolute biases 92% for scans across a wide range of CL values, but the percentage was lower for scans with amyloid loads closer to the range of typical positivity thresholds. Uncertainty estimates should always be considered when interpreting results.
- Open Access
- 23 December 2025
- Published by Wiley in Alzheimer's & Dementia
- Vol. 21 (S8) , e109944
Creating a multi‐centre Amyloid PET dataset for DLB patients: Design and Methodology
Background: Dementia with Lewy Bodies (DLB) is often misdiagnosed or conflated with Alzheimer’s Disease (AD) due to overlapping clinical presentations and neuropathological features. The presence of AD‐like features correlates with accelerated cognitive decline and a worse overall prognosis. Compared to AD, studies suggest that amyloid uptake in DLB may spare the occipital lobe. This project aims to investigate whether amyloid PET could be leveraged to differentiate between AD and DLB patients, with the goal of improving diagnostic accuracy and supporting patient stratification and safety in anti‐amyloid trials. Method: This study involves collaboration across six centres (University of Geneva, BioFINDER, AMPLE, AMYPAD PNHS, MCSA, GEHC), each contributing amyloid PET imaging data from patients diagnosed with DLB based on clinical or neuropathological assessments. Moreover, each center provided an additional subset of AD and healthy controls, then matched to DLB samples based on age/sex/APOE genotype/education for comparison. A sub analysis will be performed on patients with evidence of both DLB and AD markers. Given the relatively small sample size, key aspect of the methodological approach is to reduce technical sources of variability. The processing workflow includes rigorous quality control, formatting, normalisation to MNI space, harmonisation (differential smoothing), and MRI‐based segmentation. Result: The dataset currently includes amyloid PET scans (acquired using [ 11 C]PiB, [ 18 F]Flutemetamol or [ 18 F]Florbetapir) and MRI scans from ∼130 DLB patients, along with ∼150 AD patients and ∼150 controls. In addition, 99 patients positive for the CSF α‐Synuclein Seeding Amplification Assay were included. Patient data were anonymized, and a harmonised database was created, including demographic characteristics, clinical history, and results from neuropsychological assessments. Conclusion: The creation of a standardized, multi‐centre amyloid PET dataset for DLB will enable the study of amyloid PET patterns at the global, regional and voxel level, in comparison with uptake in AD patients and controls. This dataset will serve as a valuable resource for investigating the neuropathological underpinnings of DLB, improving diagnostic accuracy, and potentially guiding patient stratification in anti‐amyloid trials. Efforts to integrate [ 18 F]Florbetaben and additional data are ongoing.
- 23 December 2025
- Published by Wiley in Alzheimer's & Dementia
- Vol. 21 (S8) , e109944
Open AccessCreating a multi‐centre Amyloid PET dataset for DLB patients: Design and Methodology
Background: Dementia with Lewy Bodies (DLB) is often misdiagnosed or conflated with Alzheimer’s Disease (AD) due to overlapping clinical presentations and neuropathological features. The presence of AD‐like features correlates with accelerated cognitive decline and a worse overall prognosis. Compared to AD, studies suggest that amyloid uptake in DLB may spare the occipital lobe. This project aims to investigate whether amyloid PET could be leveraged to differentiate between AD and DLB patients, with the goal of improving diagnostic accuracy and supporting patient stratification and safety in anti‐amyloid trials. Method: This study involves collaboration across six centres (University of Geneva, BioFINDER, AMPLE, AMYPAD PNHS, MCSA, GEHC), each contributing amyloid PET imaging data from patients diagnosed with DLB based on clinical or neuropathological assessments. Moreover, each center provided an additional subset of AD and healthy controls, then matched to DLB samples based on age/sex/APOE genotype/education for comparison. A sub analysis will be performed on patients with evidence of both DLB and AD markers. Given the relatively small sample size, key aspect of the methodological approach is to reduce technical sources of variability. The processing workflow includes rigorous quality control, formatting, normalisation to MNI space, harmonisation (differential smoothing), and MRI‐based segmentation. Result: The dataset currently includes amyloid PET scans (acquired using [ 11 C]PiB, [ 18 F]Flutemetamol or [ 18 F]Florbetapir) and MRI scans from ∼130 DLB patients, along with ∼150 AD patients and ∼150 controls. In addition, 99 patients positive for the CSF α‐Synuclein Seeding Amplification Assay were included. Patient data were anonymized, and a harmonised database was created, including demographic characteristics, clinical history, and results from neuropsychological assessments. Conclusion: The creation of a standardized, multi‐centre amyloid PET dataset for DLB will enable the study of amyloid PET patterns at the global, regional and voxel level, in comparison with uptake in AD patients and controls. This dataset will serve as a valuable resource for investigating the neuropathological underpinnings of DLB, improving diagnostic accuracy, and potentially guiding patient stratification in anti‐amyloid trials. Efforts to integrate [ 18 F]Florbetaben and additional data are ongoing.
- Open Access
- 1 October 2025
- Published by Wiley in Alzheimer's & Dementia: Translational Research & Clinical Interventions
- Vol. 11 (4)
Implementing robust amyloid PET quantification in multi‐center studies: AMYPAD approach to address data acquisition, processing, interpretation and data sharing challenges
INTRODUCTION: Amyloid‐positron emission tomography (PET) is pivotal to Alzheimer's management, with the Centiloid standardizing measurements across tracers. AMYPAD trials (Diagnostic and Patient Management Study [DPMS] and Prognostic and Natural History Study [PNHS]) aimed to validate robust quantification in clinical settings. We report our comprehensive approach to amyloid‐PET implementation, comprising scan acquisition, harmonization, data storing, and data sharing strategies. METHODS: Data from 28 scanners were harmonized using Hoffman phantoms. Three quantification workflows were compared: AmyPype (PET‐only), IXICO‐LEAP, and the standard Centiloid pipeline (magnetic resonance imaging [MRI]‐based). Distributions of Centiloids were assessed using Gaussian Mixture Modeling. RESULTS: Binary quantification showed excellent concordance between pipelines (≥ 96%) and compared to visual reads (>90%). DPMS Centiloids had a bimodal distribution while the PNHS showed a more skewed distribution toward higher Centiloids modeled with three Gaussians (1 st Gaussian mean + 2SD = 12 CL, emerging pathology). DISCUSSION: The harmonization framework, providing strong cross‐method correlations in AMYPAD, has been adopted by EARL as the Brain PET/CT accreditation standard and provides a practical approach for other multi‐center cohorts to implement similar strategies. Highlights: We share AMYPAD's end‐to‐end approach to amyloid positron emission tomography (PET) quantification from data acquisition and handling, harmonization based on Hoffman phantoms, quality control, image processing, to data storage, and data sharing strategies. Centiloid quantification was compared across one PET‐only (AmyPype) and two PET‐MR pipelines (standard Centiloid and IXIXO‐LEAP). Excellent agreement in dichotomized Centiloid valued was observed both between pipelines and when compared to visual reads. Distribution of Centiloid values in the Prognostic and Natural History Study (PNHS) and Diagnostic and Patient Management Study (DPMS) are in line with the initial recruitment strategies of the trials. Harmonization of Amyloid‐PET scans framework was adopted by EARL as the Brain PET/CT accreditation standard for multicentre brain PET scans.
- 1 October 2025
- Published by Wiley in Alzheimer's & Dementia: Translational Research & Clinical Interventions
- Vol. 11 (4)
Open AccessImplementing robust amyloid PET quantification in multi‐center studies: AMYPAD approach to address data acquisition, processing, interpretation and data sharing challenges
INTRODUCTION: Amyloid‐positron emission tomography (PET) is pivotal to Alzheimer's management, with the Centiloid standardizing measurements across tracers. AMYPAD trials (Diagnostic and Patient Management Study [DPMS] and Prognostic and Natural History Study [PNHS]) aimed to validate robust quantification in clinical settings. We report our comprehensive approach to amyloid‐PET implementation, comprising scan acquisition, harmonization, data storing, and data sharing strategies. METHODS: Data from 28 scanners were harmonized using Hoffman phantoms. Three quantification workflows were compared: AmyPype (PET‐only), IXICO‐LEAP, and the standard Centiloid pipeline (magnetic resonance imaging [MRI]‐based). Distributions of Centiloids were assessed using Gaussian Mixture Modeling. RESULTS: Binary quantification showed excellent concordance between pipelines (≥ 96%) and compared to visual reads (>90%). DPMS Centiloids had a bimodal distribution while the PNHS showed a more skewed distribution toward higher Centiloids modeled with three Gaussians (1 st Gaussian mean + 2SD = 12 CL, emerging pathology). DISCUSSION: The harmonization framework, providing strong cross‐method correlations in AMYPAD, has been adopted by EARL as the Brain PET/CT accreditation standard and provides a practical approach for other multi‐center cohorts to implement similar strategies. Highlights: We share AMYPAD's end‐to‐end approach to amyloid positron emission tomography (PET) quantification from data acquisition and handling, harmonization based on Hoffman phantoms, quality control, image processing, to data storage, and data sharing strategies. Centiloid quantification was compared across one PET‐only (AmyPype) and two PET‐MR pipelines (standard Centiloid and IXIXO‐LEAP). Excellent agreement in dichotomized Centiloid valued was observed both between pipelines and when compared to visual reads. Distribution of Centiloid values in the Prognostic and Natural History Study (PNHS) and Diagnostic and Patient Management Study (DPMS) are in line with the initial recruitment strategies of the trials. Harmonization of Amyloid‐PET scans framework was adopted by EARL as the Brain PET/CT accreditation standard for multicentre brain PET scans.
- Open Access
- 9 January 2025
- Vol. 20 (Suppl 8)
Centiloid over time: normal ageing or pathological accumulation?
The Centiloid method (CL) was introduced as a tracer‐independent measure for cortical amyloid load and is now commonly used in Alzheimer’s disease (AD) clinical trials. To facilitate its implementation into clinical settings, the AMYPAD consortium set out to integrate existing literature and recent work from the consortium to provide clinical context‐of‐use recommendations of the Centiloid scale, which has been submitted to the European Medicine Agency for endorsement as a Biomarker Qualification Opinion. Screening of the literature was performed on the 7/11/23 on PubMed to identify articles mentioning “Centiloid”. The 159 results were reviewed to identify all cut‐offs established based on histopathology, visual reads, fluid biomarkers and cognition. Clinical trials inclusion criteria and amyloid clearance strategies were also included. Compared to histopathology (gold standard), visual reads, and cerebrospinal fluid (clinical standards), Centiloid quantification accurately reflects the amount of AD pathology. With high certainty at the individual level, a CL value below 10 excludes the presence of Aβ pathology, while a value above 30 is a conservative estimate of amyloid‐positivity (Figure‐1). Values falling in between these two cut‐offs (i.e., ‘gray‐zone’) are related to an increased risk of disease progression, but future studies enriched for this population are needed. The AMYPAD consortium additionally assessed the robustness and measurement uncertainty of the Centiloid scale and demonstrated that the method is highly robust against pipeline differences, such as processing space, target region, and reference region, though use of the pons could lead to increased bias and is not recommended. Measurement uncertainty was 3 to 8.3 CL across the total scale and is amyloid burden dependent. Four clinical context‐of‐use for CL quantification are proposed: 1) adjunct to visual inspection methodology to achieve high certainty regarding the presence or absence of Aβ pathology, 2) a CL level of >30 could be utilised as a conservative cut‐off for the presence of Aβ pathology to guide the management of patients with objective cognitive impairment who may be eligible for anti‐amyloid disease‐modifying therapies, 3) support therapy monitoring and treatment decisions, 4) identification of emerging amyloid deposition and optimize risk‐stratification. Accounting for measurement uncertainty is essential when interpreting CL units.
- 9 January 2025
- Vol. 20 (Suppl 8)
Open AccessCentiloid over time: normal ageing or pathological accumulation?
The Centiloid method (CL) was introduced as a tracer‐independent measure for cortical amyloid load and is now commonly used in Alzheimer’s disease (AD) clinical trials. To facilitate its implementation into clinical settings, the AMYPAD consortium set out to integrate existing literature and recent work from the consortium to provide clinical context‐of‐use recommendations of the Centiloid scale, which has been submitted to the European Medicine Agency for endorsement as a Biomarker Qualification Opinion. Screening of the literature was performed on the 7/11/23 on PubMed to identify articles mentioning “Centiloid”. The 159 results were reviewed to identify all cut‐offs established based on histopathology, visual reads, fluid biomarkers and cognition. Clinical trials inclusion criteria and amyloid clearance strategies were also included. Compared to histopathology (gold standard), visual reads, and cerebrospinal fluid (clinical standards), Centiloid quantification accurately reflects the amount of AD pathology. With high certainty at the individual level, a CL value below 10 excludes the presence of Aβ pathology, while a value above 30 is a conservative estimate of amyloid‐positivity (Figure‐1). Values falling in between these two cut‐offs (i.e., ‘gray‐zone’) are related to an increased risk of disease progression, but future studies enriched for this population are needed. The AMYPAD consortium additionally assessed the robustness and measurement uncertainty of the Centiloid scale and demonstrated that the method is highly robust against pipeline differences, such as processing space, target region, and reference region, though use of the pons could lead to increased bias and is not recommended. Measurement uncertainty was 3 to 8.3 CL across the total scale and is amyloid burden dependent. Four clinical context‐of‐use for CL quantification are proposed: 1) adjunct to visual inspection methodology to achieve high certainty regarding the presence or absence of Aβ pathology, 2) a CL level of >30 could be utilised as a conservative cut‐off for the presence of Aβ pathology to guide the management of patients with objective cognitive impairment who may be eligible for anti‐amyloid disease‐modifying therapies, 3) support therapy monitoring and treatment decisions, 4) identification of emerging amyloid deposition and optimize risk‐stratification. Accounting for measurement uncertainty is essential when interpreting CL units.
- Open Access
- 1 December 2024
- Published by Wiley in Alzheimer's & Dementia
- Vol. 20 (S2) , e086564
The Centiloid scale: guidance on clinical context of use from the AMYPAD Consortium
Background: The Centiloid method (CL) was introduced as a tracer‐independent measure for cortical amyloid load and is now commonly used in Alzheimer’s disease (AD) clinical trials. To facilitate its implementation into clinical settings, the AMYPAD consortium set out to integrate existing literature and recent work from the consortium to provide clinical context‐of‐use recommendations of the Centiloid scale, which has been submitted to the European Medicine Agency for endorsement as a Biomarker Qualification Opinion.Method: Screening of the literature was performed on the 7/11/23 on PubMed to identify articles mentioning “Centiloid”. The 159 results were reviewed to identify all cut‐offs established based on histopathology, visual reads, fluid biomarkers and cognition. Clinical trials inclusion criteria and amyloid clearance strategies were also included.Result: Compared to histopathology (gold standard), visual reads, and cerebrospinal fluid (clinical standards), Centiloid quantification accurately reflects the amount of AD pathology. With high certainty at the individual level, a CL value below 10 excludes the presence of Aβ pathology, while a value above 30 is a conservative estimate of amyloid‐positivity (Figure 1). Values falling in between these two cut‐offs (i.e., ‘gray‐zone’) are related to an increased risk of disease progression, but future studies enriched for this population are needed. The AMYPAD consortium additionally assessed the robustness and measurement uncertainty of the Centiloid scale and demonstrated that the method is highly robust against pipeline differences, such as processing space, target region, and reference region, though use of the pons could lead to increased bias and is not recommended. Measurement uncertainty was 3 to 8.3 CL across the total scale and is amyloid burden dependent.Conclusion: Four clinical context‐of‐use for CL quantification are proposed: 1) adjunct to visual inspection methodology to achieve high certainty regarding the presence or absence of Aβ pathology, 2) a CL level of >30 could be utilised as a conservative cut‐off for the presence of Aβ pathology to guide the management of patients with objective cognitive impairment who may be eligible for anti‐amyloid disease‐modifying therapies, 3) support therapy monitoring and treatment decisions, 4) identification of emerging amyloid deposition and optimize risk‐stratification. Accounting for measurement uncertainty is essential when interpreting CL units.
- 1 December 2024
- Published by Wiley in Alzheimer's & Dementia
- Vol. 20 (S2) , e086564
Open AccessThe Centiloid scale: guidance on clinical context of use from the AMYPAD Consortium
Background: The Centiloid method (CL) was introduced as a tracer‐independent measure for cortical amyloid load and is now commonly used in Alzheimer’s disease (AD) clinical trials. To facilitate its implementation into clinical settings, the AMYPAD consortium set out to integrate existing literature and recent work from the consortium to provide clinical context‐of‐use recommendations of the Centiloid scale, which has been submitted to the European Medicine Agency for endorsement as a Biomarker Qualification Opinion.Method: Screening of the literature was performed on the 7/11/23 on PubMed to identify articles mentioning “Centiloid”. The 159 results were reviewed to identify all cut‐offs established based on histopathology, visual reads, fluid biomarkers and cognition. Clinical trials inclusion criteria and amyloid clearance strategies were also included.Result: Compared to histopathology (gold standard), visual reads, and cerebrospinal fluid (clinical standards), Centiloid quantification accurately reflects the amount of AD pathology. With high certainty at the individual level, a CL value below 10 excludes the presence of Aβ pathology, while a value above 30 is a conservative estimate of amyloid‐positivity (Figure 1). Values falling in between these two cut‐offs (i.e., ‘gray‐zone’) are related to an increased risk of disease progression, but future studies enriched for this population are needed. The AMYPAD consortium additionally assessed the robustness and measurement uncertainty of the Centiloid scale and demonstrated that the method is highly robust against pipeline differences, such as processing space, target region, and reference region, though use of the pons could lead to increased bias and is not recommended. Measurement uncertainty was 3 to 8.3 CL across the total scale and is amyloid burden dependent.Conclusion: Four clinical context‐of‐use for CL quantification are proposed: 1) adjunct to visual inspection methodology to achieve high certainty regarding the presence or absence of Aβ pathology, 2) a CL level of >30 could be utilised as a conservative cut‐off for the presence of Aβ pathology to guide the management of patients with objective cognitive impairment who may be eligible for anti‐amyloid disease‐modifying therapies, 3) support therapy monitoring and treatment decisions, 4) identification of emerging amyloid deposition and optimize risk‐stratification. Accounting for measurement uncertainty is essential when interpreting CL units.
- Top Cited PapersOpen Access
- 20 November 2024
- Published by Wiley in Alzheimer's & Dementia
- Vol. 20 (12) , 9037-9048
Centiloid recommendations for clinical context‐of‐use from the AMYPAD consortium
Amyloid‐PET quantification through the tracer‐independent Centiloid (CL) scale has emerged as an essential tool for the accurate measurement of amyloid‐β (Aβ) pathology in Alzheimer's disease (AD) patients. The AMYPAD consortium set out to integrate existing literature and recent work from the consortium to provide clinical context‐of‐use recommendations for the CL scale. Compared to histopathology, visual reads, and cerebrospinal fluid, CL quantification accurately reflects the amount of AD pathology. With high certainty, a CL value below 10 excludes the presence of Aβ pathology, while a value above 30 corresponds well with pathological amounts. Values falling in between these two cutoffs (“intermediate range”) are related to an increased risk of disease progression. Together, CL quantification is a valuable adjunct to visual assessments of amyloid‐PET images. An abnormal amyloid biomarker assessment is a key criterion to determine eligibility for anti‐amyloid disease‐modifying therapies, and amyloid‐PET quantification can add further value by precisely monitoring amyloid clearance, and hence guiding patient management decisions.Highlights: Centiloid (CL) quantification robustly reflects of the amount of Aβ pathology. CL < 10/CL > 30 reflects Aβ‐negativity/positivity thresholds with high certainty. CL quantification is a valuable adjunct to visual assessments of amyloid‐PET. CL quantification can support trial design and treatment management. CL quantification could support the identification of early or emerging Aβ pathology.
- 20 November 2024
- Published by Wiley in Alzheimer's & Dementia
- Vol. 20 (12) , 9037-9048
Top Cited PapersOpen AccessCentiloid recommendations for clinical context‐of‐use from the AMYPAD consortium
Amyloid‐PET quantification through the tracer‐independent Centiloid (CL) scale has emerged as an essential tool for the accurate measurement of amyloid‐β (Aβ) pathology in Alzheimer's disease (AD) patients. The AMYPAD consortium set out to integrate existing literature and recent work from the consortium to provide clinical context‐of‐use recommendations for the CL scale. Compared to histopathology, visual reads, and cerebrospinal fluid, CL quantification accurately reflects the amount of AD pathology. With high certainty, a CL value below 10 excludes the presence of Aβ pathology, while a value above 30 corresponds well with pathological amounts. Values falling in between these two cutoffs (“intermediate range”) are related to an increased risk of disease progression. Together, CL quantification is a valuable adjunct to visual assessments of amyloid‐PET images. An abnormal amyloid biomarker assessment is a key criterion to determine eligibility for anti‐amyloid disease‐modifying therapies, and amyloid‐PET quantification can add further value by precisely monitoring amyloid clearance, and hence guiding patient management decisions.Highlights: Centiloid (CL) quantification robustly reflects of the amount of Aβ pathology. CL < 10/CL > 30 reflects Aβ‐negativity/positivity thresholds with high certainty. CL quantification is a valuable adjunct to visual assessments of amyloid‐PET. CL quantification can support trial design and treatment management. CL quantification could support the identification of early or emerging Aβ pathology.
- Open Access
- 4 April 2024
- Published by Wiley in Alzheimer's & Dementia
- Vol. 20 (5) , 3429-3441
Investigating reliable amyloid accumulation in Centiloids: Results from the AMYPAD Prognostic and Natural History Study
INTRODUCTION: To support clinical trial designs focused on early interventions, our study determined reliable early amyloid‐β (Aβ) accumulation based on Centiloids (CL) in pre‐dementia populations.METHODS: A total of 1032 participants from the Amyloid Imaging to Prevent Alzheimer's Disease–Prognostic and Natural History Study (AMYPAD‐PNHS) and Insight46 who underwent [18F]flutemetamol, [18F]florbetaben or [18F]florbetapir amyloid‐PET were included. A normative strategy was used to define reliable accumulation by estimating the 95th percentile of longitudinal measurements in sub‐populations (NPNHS = 101/750, NInsight46 = 35/382) expected to remain stable over time. The baseline CL threshold that optimally predicts future accumulation was investigated using precision‐recall analyses. Accumulation rates were examined using linear mixed‐effect models.RESULTS: Reliable accumulation in the PNHS was estimated to occur at >3.0 CL/year. Baseline CL of 16 [12,19] best predicted future Aβ‐accumulators. Rates of amyloid accumulation were tracer‐independent, lower for APOE ε4 non‐carriers, and for subjects with higher levels of education.DISCUSSION: Our results support a 12–20 CL window for inclusion into early secondary prevention studies. Reliable accumulation definition warrants further investigations.
- 4 April 2024
- Published by Wiley in Alzheimer's & Dementia
- Vol. 20 (5) , 3429-3441
Open AccessInvestigating reliable amyloid accumulation in Centiloids: Results from the AMYPAD Prognostic and Natural History Study
INTRODUCTION: To support clinical trial designs focused on early interventions, our study determined reliable early amyloid‐β (Aβ) accumulation based on Centiloids (CL) in pre‐dementia populations.METHODS: A total of 1032 participants from the Amyloid Imaging to Prevent Alzheimer's Disease–Prognostic and Natural History Study (AMYPAD‐PNHS) and Insight46 who underwent [18F]flutemetamol, [18F]florbetaben or [18F]florbetapir amyloid‐PET were included. A normative strategy was used to define reliable accumulation by estimating the 95th percentile of longitudinal measurements in sub‐populations (NPNHS = 101/750, NInsight46 = 35/382) expected to remain stable over time. The baseline CL threshold that optimally predicts future accumulation was investigated using precision‐recall analyses. Accumulation rates were examined using linear mixed‐effect models.RESULTS: Reliable accumulation in the PNHS was estimated to occur at >3.0 CL/year. Baseline CL of 16 [12,19] best predicted future Aβ‐accumulators. Rates of amyloid accumulation were tracer‐independent, lower for APOE ε4 non‐carriers, and for subjects with higher levels of education.DISCUSSION: Our results support a 12–20 CL window for inclusion into early secondary prevention studies. Reliable accumulation definition warrants further investigations.