Christopher M. Polleys
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Christopher M. Polleys has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Irene Georgakoudi
Tufts Unive
5 shared publications - Abani Patra
Data Intensive Studies Center, Tufts University, Medford, MA 02155, USA
3 shared publications - Narges Jahanseir
Department of Pathology and Laboratory Medicine, Tufts University School of Medicine, Tufts Medical Center
3 shared publications - Elizabeth M. Genega
Tufts University School of Medicine, Tufts Medical Center, Department of Pathology and Laboratory Medicine, Boston, Massachusetts, United States
2 shared publications - Eric L. Miller
Center for Applied Brain and Cognitive Sciences, Tufts University, Medford, MA 02155, USA
2 shared publications - Filippos Sakellariou
Anatolia College, Thessaloniki, Greece
2 shared publications
Latest Publications
- Open Access
Rapid, high-resolution, non-destructive assessments of metabolic and morphological homogeneity uniquely identify high-grade cervical precancerous lesions
Purpose Two-photon microscopy (2PM) is an emerging clinical imaging modality with the potential to non-invasively assess tissue metabolism and morphology in high-resolution. This study aimed to assess the translational potential of 2PM for improved detection of high-grade cervical precancerous lesions. Experimental Design 2P images attributed to reduced nicotinamide adenine dinucleotide (phosphate) (NAD(P)H) and oxidized flavoproteins (FP) were acquired from the full epithelial thickness of freshly excised human cervical tissue biopsies (N = 62). Fifteen biopsies harbored high-grade squamous intraepithelial lesions (HSILs), 14 biopsies harbored low-grade SILs (LSILs), and 33 biopsies were benign. Quadratic discriminant analysis (QDA) leveraged morphological and metabolic functional metrics extracted from these images to predict the presence of HSILs. We performed gene set enrichment analysis (GSEA) using datasets available on the Gene Expression Omnibus (GEO) to validate the presence of metabolic reprogramming in HSILs. Results Integrating metabolic and morphological 2P-derived metrics from finely sampled, full-thickness epithelia achieved a high 90.8 ± 6.1% sensitivity and 72.3 ± 11.3% specificity of HSIL detection. Notably, sensitivity (91.4 ± 12.0%) and specificity (77.5 ± 12.6%) were maintained when utilizing metrics from only two images at 12- and 72-µm from the tissue surface. Upregulation of glycolysis, fatty acid metabolism, and oxidative phosphorylation in HSIL tissues validated the metabolic reprogramming captured by 2P biomarkers. Conclusion Label-free 2P images from as few as two epithelial depths enable rapid and robust HSIL detection through the quantitative characterization of metabolic and morphological reprogramming, underscoring the potential of this tool for clinical evaluation of cervical precancers. Translational Relevance Statement The colposcopy and biopsy paradigm for cervical pre-cancer detection leads to an excessive number of unnecessary biopsies, with significant economic and psychological costs. This study highlights the potential of label-free, high-resolution two photon imaging to improve this paradigm by introducing real-time morphofunctional tissue assessments. In an extensive dataset comprising freshly excised high-grade and low-grade cervical intraepithelial lesions, along with benign metaplastic and inflamed human cervical tissue biopsies, we successfully characterize a loss of morphofunctional heterogeneity indicative of high-grade precancerous changes. Leveraging a combination of two-photon imaging-derived quantitative morphofunctional metrics, our findings showcase a substantial improvement in both sensitivity and specificity of high-grade lesion detection compared to the current gold standard of colposcopy followed by a single biopsy. The demonstrated enhancement in sensitivity and specificity highlights the prospect of integrating non-invasive, label-free metabolic imaging into clinical practice, offering a more effective and efficient approach to identify and manage cervical precancerous lesions.
Open AccessRapid, high-resolution, non-destructive assessments of metabolic and morphological homogeneity uniquely identify high-grade cervical precancerous lesions
Purpose Two-photon microscopy (2PM) is an emerging clinical imaging modality with the potential to non-invasively assess tissue metabolism and morphology in high-resolution. This study aimed to assess the translational potential of 2PM for improved detection of high-grade cervical precancerous lesions. Experimental Design 2P images attributed to reduced nicotinamide adenine dinucleotide (phosphate) (NAD(P)H) and oxidized flavoproteins (FP) were acquired from the full epithelial thickness of freshly excised human cervical tissue biopsies (N = 62). Fifteen biopsies harbored high-grade squamous intraepithelial lesions (HSILs), 14 biopsies harbored low-grade SILs (LSILs), and 33 biopsies were benign. Quadratic discriminant analysis (QDA) leveraged morphological and metabolic functional metrics extracted from these images to predict the presence of HSILs. We performed gene set enrichment analysis (GSEA) using datasets available on the Gene Expression Omnibus (GEO) to validate the presence of metabolic reprogramming in HSILs. Results Integrating metabolic and morphological 2P-derived metrics from finely sampled, full-thickness epithelia achieved a high 90.8 ± 6.1% sensitivity and 72.3 ± 11.3% specificity of HSIL detection. Notably, sensitivity (91.4 ± 12.0%) and specificity (77.5 ± 12.6%) were maintained when utilizing metrics from only two images at 12- and 72-µm from the tissue surface. Upregulation of glycolysis, fatty acid metabolism, and oxidative phosphorylation in HSIL tissues validated the metabolic reprogramming captured by 2P biomarkers. Conclusion Label-free 2P images from as few as two epithelial depths enable rapid and robust HSIL detection through the quantitative characterization of metabolic and morphological reprogramming, underscoring the potential of this tool for clinical evaluation of cervical precancers. Translational Relevance Statement The colposcopy and biopsy paradigm for cervical pre-cancer detection leads to an excessive number of unnecessary biopsies, with significant economic and psychological costs. This study highlights the potential of label-free, high-resolution two photon imaging to improve this paradigm by introducing real-time morphofunctional tissue assessments. In an extensive dataset comprising freshly excised high-grade and low-grade cervical intraepithelial lesions, along with benign metaplastic and inflamed human cervical tissue biopsies, we successfully characterize a loss of morphofunctional heterogeneity indicative of high-grade precancerous changes. Leveraging a combination of two-photon imaging-derived quantitative morphofunctional metrics, our findings showcase a substantial improvement in both sensitivity and specificity of high-grade lesion detection compared to the current gold standard of colposcopy followed by a single biopsy. The demonstrated enhancement in sensitivity and specificity highlights the prospect of integrating non-invasive, label-free metabolic imaging into clinical practice, offering a more effective and efficient approach to identify and manage cervical precancerous lesions.
- Open Access
- 1 December 2023
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 28 (12) , 126006-21
Restoration of metabolic functional metrics from label-free, two-photon human tissue images using multiscale deep-learning-based denoising algorithms
SignificanceLabel-free, two-photon excited fluorescence (TPEF) imaging captures morphological and functional metabolic tissue changes and enables enhanced understanding of numerous diseases. However, noise and other artifacts present in these images severely complicate the extraction of biologically useful information.AimWe aim to employ deep neural architectures in the synthesis of a multiscale denoising algorithm optimized for restoring metrics of metabolic activity from low-signal-to-noise ratio (SNR), TPEF images.ApproachTPEF images of reduced nicotinamide adenine dinucleotide (phosphate) (NAD(P)H) and flavoproteins (FAD) from freshly excised human cervical tissues are used to assess the impact of various denoising models, preprocessing methods, and data on metrics of image quality and the recovery of six metrics of metabolic function from the images relative to ground truth images.ResultsOptimized recovery of the redox ratio and mitochondrial organization is achieved using a novel algorithm based on deep denoising in the wavelet transform domain. This algorithm also leads to significant improvements in peak-SNR (PSNR) and structural similarity index measure (SSIM) for all images. Interestingly, other models yield even higher PSNR and SSIM improvements, but they are not optimal for recovery of metabolic function metrics.ConclusionsDenoising algorithms can recover diagnostically useful information from low SNR label-free TPEF images and will be useful for the clinical translation of such imaging.
- 1 December 2023
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 28 (12) , 126006-21
Open AccessRestoration of metabolic functional metrics from label-free, two-photon human tissue images using multiscale deep-learning-based denoising algorithms
SignificanceLabel-free, two-photon excited fluorescence (TPEF) imaging captures morphological and functional metabolic tissue changes and enables enhanced understanding of numerous diseases. However, noise and other artifacts present in these images severely complicate the extraction of biologically useful information.AimWe aim to employ deep neural architectures in the synthesis of a multiscale denoising algorithm optimized for restoring metrics of metabolic activity from low-signal-to-noise ratio (SNR), TPEF images.ApproachTPEF images of reduced nicotinamide adenine dinucleotide (phosphate) (NAD(P)H) and flavoproteins (FAD) from freshly excised human cervical tissues are used to assess the impact of various denoising models, preprocessing methods, and data on metrics of image quality and the recovery of six metrics of metabolic function from the images relative to ground truth images.ResultsOptimized recovery of the redox ratio and mitochondrial organization is achieved using a novel algorithm based on deep denoising in the wavelet transform domain. This algorithm also leads to significant improvements in peak-SNR (PSNR) and structural similarity index measure (SSIM) for all images. Interestingly, other models yield even higher PSNR and SSIM improvements, but they are not optimal for recovery of metabolic function metrics.ConclusionsDenoising algorithms can recover diagnostically useful information from low SNR label-free TPEF images and will be useful for the clinical translation of such imaging.
- Open Access
- 10 November 2023
- Published by Elsevier in Journal of Investigative Dermatology
- Vol. 144 (4) , 912-915.e2
Noninvasive Imaging Techniques for Monitoring Cellular Response to Treatment in Stable Vitiligo
- 10 November 2023
- Published by Elsevier in Journal of Investigative Dermatology
- Vol. 144 (4) , 912-915.e2
Open AccessNoninvasive Imaging Techniques for Monitoring Cellular Response to Treatment in Stable Vitiligo
- Open Access
Formalin fixation and paraffin embedding interfere with preservation of optical metabolic assessments based on endogenous NAD(P)H and FAD two photon excited fluorescence
Endogenous NAD(P)H and FAD two-photon excited fluorescence (TPEF) images provide functional metabolic information with high spatial resolution for a wide range of living specimens. Preservation of metabolic function optical metrics upon fixation would facilitate studies which assess the impact of metabolic changes in the context of numerous diseases. However, robust assessments of the impact of formalin fixation, paraffin embedding, and sectioning on the preservation of optical metabolic readouts are lacking. Here, we evaluate intensity and lifetime images at excitation/emission settings optimized for NAD(P)H and FAD TPEF detection from freshly excised murine oral epithelia and corresponding bulk and sectioned fixed tissues. We find that fixation impacts the overall intensity as well as the intensity fluctuations of the images acquired. Accordingly, the depth-dependent variations of the optical redox ratio (defined as FAD/(NAD(P)H + FAD)) across squamous epithelia are not preserved following fixation. This is consistent with significant changes in the 755 nm excited spectra, which reveal broadening upon fixation and additional distortions upon paraffin embedding and sectioning. Analysis of fluorescence lifetime images acquired for excitation/emission settings optimized for NAD(P)H TPEF detection indicate that fixation alters the long lifetime of the observed fluorescence and the long lifetime intensity fraction. These parameters as well as the short TPEF lifetime are significantly modified upon embedding and sectioning. Thus, our studies highlight that the autofluorescence products formed during formalin fixation, paraffin embedding and sectioning overlap highly with NAD(P)H and FAD emission and limit the potential to utilize such tissues to assess metabolic activity.
Open AccessFormalin fixation and paraffin embedding interfere with preservation of optical metabolic assessments based on endogenous NAD(P)H and FAD two photon excited fluorescence
Endogenous NAD(P)H and FAD two-photon excited fluorescence (TPEF) images provide functional metabolic information with high spatial resolution for a wide range of living specimens. Preservation of metabolic function optical metrics upon fixation would facilitate studies which assess the impact of metabolic changes in the context of numerous diseases. However, robust assessments of the impact of formalin fixation, paraffin embedding, and sectioning on the preservation of optical metabolic readouts are lacking. Here, we evaluate intensity and lifetime images at excitation/emission settings optimized for NAD(P)H and FAD TPEF detection from freshly excised murine oral epithelia and corresponding bulk and sectioned fixed tissues. We find that fixation impacts the overall intensity as well as the intensity fluctuations of the images acquired. Accordingly, the depth-dependent variations of the optical redox ratio (defined as FAD/(NAD(P)H + FAD)) across squamous epithelia are not preserved following fixation. This is consistent with significant changes in the 755 nm excited spectra, which reveal broadening upon fixation and additional distortions upon paraffin embedding and sectioning. Analysis of fluorescence lifetime images acquired for excitation/emission settings optimized for NAD(P)H TPEF detection indicate that fixation alters the long lifetime of the observed fluorescence and the long lifetime intensity fraction. These parameters as well as the short TPEF lifetime are significantly modified upon embedding and sectioning. Thus, our studies highlight that the autofluorescence products formed during formalin fixation, paraffin embedding and sectioning overlap highly with NAD(P)H and FAD emission and limit the potential to utilize such tissues to assess metabolic activity.
- Open Access
Restoration of metabolic functional metrics from label-free, two-photon cervical tissue images using multiscale deep-learning-based denoising algorithms
Label-free, two-photon imaging captures morphological and functional metabolic tissue changes and enables enhanced understanding of numerous diseases. However, this modality suffers from low signal arising from limitations imposed by the maximum permissible dose of illumination and the need for rapid image acquisition to avoid motion artifacts. Recently, deep learning methods have been developed to facilitate the extraction of quantitative information from such images. Here, we employ deep neural architectures in the synthesis of a multiscale denoising algorithm optimized for restoring metrics of metabolic activity from low-SNR, two-photon images. Two-photon excited fluorescence (TPEF) images of reduced nicotinamide adenine dinucleotide (phosphate) (NAD(P)H) and flavoproteins (FAD) from freshly excised human cervical tissues are used. We assess the impact of the specific denoising model, loss function, data transformation, and training dataset on established metrics of image restoration when comparing denoised single frame images with corresponding six frame averages, considered as the ground truth. We further assess the restoration accuracy of six metrics of metabolic function from the denoised images relative to ground truth images. Using a novel algorithm based on deep denoising in the wavelet transform domain, we demonstrate optimal recovery of metabolic function metrics. Our results highlight the promise of denoising algorithms to recover diagnostically useful information from low SNR label-free two-photon images and their potential importance in the clinical translation of such imaging.
Open AccessRestoration of metabolic functional metrics from label-free, two-photon cervical tissue images using multiscale deep-learning-based denoising algorithms
Label-free, two-photon imaging captures morphological and functional metabolic tissue changes and enables enhanced understanding of numerous diseases. However, this modality suffers from low signal arising from limitations imposed by the maximum permissible dose of illumination and the need for rapid image acquisition to avoid motion artifacts. Recently, deep learning methods have been developed to facilitate the extraction of quantitative information from such images. Here, we employ deep neural architectures in the synthesis of a multiscale denoising algorithm optimized for restoring metrics of metabolic activity from low-SNR, two-photon images. Two-photon excited fluorescence (TPEF) images of reduced nicotinamide adenine dinucleotide (phosphate) (NAD(P)H) and flavoproteins (FAD) from freshly excised human cervical tissues are used. We assess the impact of the specific denoising model, loss function, data transformation, and training dataset on established metrics of image restoration when comparing denoised single frame images with corresponding six frame averages, considered as the ground truth. We further assess the restoration accuracy of six metrics of metabolic function from the denoised images relative to ground truth images. Using a novel algorithm based on deep denoising in the wavelet transform domain, we demonstrate optimal recovery of metabolic function metrics. Our results highlight the promise of denoising algorithms to recover diagnostically useful information from low SNR label-free two-photon images and their potential importance in the clinical translation of such imaging.