JFJohn Clinton Fisher

John Clinton Fisher

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


John Clinton Fisher has a total of 14 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    ChatGPT-4o is Not a Reliable Study Source for Orthopaedic Surgery Residents

    by Neil Jain, Caleb Gottlich, John Fisher, Travis Winston, Kristofer Matullo, Dustin Greenhill

    Background: The use of artificial intelligence platforms by medical residents as an educational resource is increasing. Within orthopaedic surgery, older Chat Generative Pre-trained Transformer (ChatGPT) models performed worse than resident physicians on practice examinations and rarely answered questions with images correctly. The newer ChatGPT-4o was designed to improve these deficiencies but has not been evaluated. This study analyzed (1) ChatGPT-4o's ability to correctly answer Orthopaedic In-Training Examination (OITE) questions and (2) the educational quality of the answer explanations that it presents to our orthopaedic surgery trainees. Methods: The 2020 to 2022 OITEs were uploaded into ChatGPT-4o. Annual score reports were used to compare the chatbot's raw score with that of ACGME-accredited orthopaedic residents. ChatGPT-4o's answer explanations were then compared with those provided by the American Academy of Orthopaedic Surgeons (AAOS) and categorized based on (1) the chatbot's answer (correct/incorrect) and (2) the chatbot's answer explanation when compared with the explanation provided by AAOS subject-matter experts (classified as consistent, disparate, or nonexistent). Overall ChatGPT-4o response quality was then simplified into 3 groups. An “ideal” response combined a correct answer with a consistent explanation. “Inadequate” responses provided a correct answer but no explanation. “Unacceptable” responses provided an incorrect answer or disparate explanation. Results: ChatGPT-4o scored 68.8%, 63.4%, and 70.1% on the 2020, 2021, and 2022 OITEs, respectively. These raw scores corresponded with ACGME-accredited postgraduate year-5 (PGY-5), PGY2-3, and PGY-4 resident physicians. Pediatrics and Spine were the only subspecialties whereby ChatGPT-4o consistently performed better than a junior resident (≥PGY-3). The quality of responses provided by ChatGPT-4o was ideal, inadequate, or unacceptable in 58.7%, 6.9%, and 34.4% of questions, respectively. ChatGPT-4o scored significantly lower on media-related questions when compared with nonmedia questions (60.0% versus 73.1%, p < 0.001). Conclusions: ChatGPT-4o performed inconsistently on the OITE. Moreover, the responses it provided trainees were not always ideal. Its limited performance on media-based orthopaedic surgery questions also persisted. The use of ChatGPT by resident physicians while studying orthopaedic surgery concepts remains unvalidated. Level of Evidence: Level IV. See Instructions for Authors for a complete description of levels of evidence.


  • Open Access

    Subtrochanteric fracture after femoral neck system of femoral neck fractures: a report of four cases

    by John C. Fisher, Christopher Gerzina, Kaitlin Rush, Cyrus Caroom

    The femoral neck system (FNS) is commonly used for internal fixation of femoral neck fractures and has shown promising results. However, we have observed cases of peri-implant subtrochanteric femur fractures associated with the use of FNS at our institution. This case series aims to investigate four cases of peri-implant subtrochanteric fractures in patients treated with the FNS implant for femoral neck fractures. We reviewed 35 patients who underwent treatment with FNS for femoral neck fractures between January 2017 and December 2021 at our level 1 trauma institution. Among these patients, four cases of peri-implant subtrochanteric femur fractures were identified. In contrast, no such fractures occurred in patients treated with cannulated screws or dynamic hip screws (DHS). Interestingly, all four cases of peri-implant fractures were seen in patients with incomplete nondisplaced femoral neck fractures. Only one case involved an identifiable technical error. This case series sheds light on peri-implant subtrochanteric femur fractures as a previously unreported complication associated with the use of FNS for femoral neck fractures. These fractures were observed exclusively in patients with incomplete nondisplaced fractures who received FNS fixation. No similar complications were observed in patients treated with other types of fixation. This finding suggests the need for caution and further investigation when considering FNS as a treatment option for this specific fracture pattern. The identification of peri-implant subtrochanteric femur fractures as a potential complication of FNS usage in incomplete nondisplaced femoral neck fractures raises important considerations for clinical decision-making and patient management in orthopedic trauma.


  • Open Access

    Subtrochanteric Fracture After Femoral Neck System of Femoral Neck Fractures: A Report of Four Cases

    by John Clinton Fisher, Christopher Gerzina, Kaitlin Rush, Cyrus Caroom

    Background: The femoral neck system (FNS) is commonly used for internal fixation of femoral neck fractures and has shown promising results. However, we have observed cases of peri-implant subtrochanteric femur fractures associated with the use of FNS at our institution. This case series aims to investigate four cases of peri-implant subtrochanteric fractures in patients treated with the FNS implant for femoral neck fractures. Case Presentation: We reviewed 35 patients who underwent treatment with FNS for femoral neck fractures between January 2017 and December 2021 at our level 1 trauma institution. Among these patients, four cases of peri-implant subtrochanteric femur fractures were identified. In contrast, no such fractures occurred in patients treated with cannulated screws or dynamic hip screws (DHS). Interestingly, all four cases of peri-implant fractures were seen in patients with incomplete nondisplaced femoral neck fractures. Only one case involved an identifiable technical error. Conclusions: This case series sheds light on peri-implant subtrochanteric femur fractures as a previously unreported complication associated with the use of FNS for femoral neck fractures. These fractures were observed exclusively in patients with incomplete nondisplaced fractures who received FNS fixation. No similar complications were observed in patients treated with other types of fixation. This finding suggests the need for caution and further investigation when considering FNS as a treatment option for this specific fracture pattern. The identification of peri-implant subtrochanteric femur fractures as a potential complication of FNS usage in incomplete nondisplaced femoral neck fractures raises important considerations for clinical decision-making and patient management in orthopedic trauma.

  • Open Access

    Procalcitonin as a Predictor of Septic Knee Arthritis: A Retrospective Cohort Study

    by Kevin West, Hasan Almekdash, John Fisher, Alexis D. Rounds, Jefferson Murphree, Jordan Simpson

    Introduction: Differentiating septic arthritis from aseptic arthritis (AA) of the knee is difficult without arthrocentesis. Although procalcitonin (PCT) has shown diagnostic value in identifying bacterial infections, it has not been established as a reliable marker for identifying septic arthritis (SA). Recent studies have shown promise in the use of PCT as a useful systemic marker for identifying septic arthritis versus AA. This observational retrospective review compares PCT with routine inflammatory markers as a tool for differentiating septic arthritis versus AA in patients with acute, atraumatic knee pain. Methods: Fifty-three consecutive patients (24 SA, 29 AA) were retrospectively reviewed at one institution with concern for SA. SA was diagnosed based on a physical examination, laboratory markers, and arthrocentesis. Laboratory indices were compared between the septic arthritis and AA groups. Data analysis was conducted to define sensitivity and specificity. Receiver operator characteristic curve analysis and regression were conducted to determine the best marker for acute SA of the knee. Results: Using multiple logistic regression, bacteremia (OR 6.75 ± 5.75) was determined to be the greatest predictor of SA. On linear regression, concomitant bacteremia (coef 3.07 ± 0.87), SA (coef 2.18 ± 0.70), and the presence of pseudogout crystals (coef 1.80 ± 0.83) on microscopy predicted an increase in PCT. Using a PCT cutoff of 0.25 ng/mL yields a sensitivity of 91.7% and specificity of 55.2% for predicting SA; however, the ideal cutoff in our series was 0.32 ng/mL with a sensitivity of 79.2% and specificity of 72.4%. PCT was superior to the white blood cell count, erythrocyte sedimentation rate, and C-reactive protein in the area under the receiver-operating characteristic curve analysis. Discussion: Procalcitonin seems to be the most sensitive and specific systemic marker in differentiating septic from AA.


  • Generation of Nuclear Tracks during Electrolysis

    by R. A. Oriani, J. C. Fisher