J Mangual
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
J Mangual has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Bernard Thibault
Cardiology Department, Montreal Heart Institute , Montreal, QC
5 shared publications L Calo
Polyclinic Casilino of Rome, Rome, Italy
5 shared publications- Nima Badie
Abbott, Sylmar, California
5 shared publications L Mcspadden
Abbott, Sylmar, United States of America
4 shared publications- Peter Henry Waddingham
Barts Heart Centre, London, United Kingdom of Great Britain & Northern Ireland
4 shared publications - Francisco Leyva
Department of Cardiology, Aston University , Birmingham, United Kingdom of Great Britain & Northern Ireland
3 shared publications
Latest Publications
- Open Access
- 8 December 2022
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 25 (2) , 536-545
Electrocardiographic imaging demonstrates electrical synchrony improvement by dynamic atrioventricular delays in patients with left bundle branch block and preserved atrioventricular conduction
Cardiac resynchronization therapy programmed to dynamically fuse pacing with intrinsic conduction using atrioventricular (AV) timing algorithms (e.g. SyncAV) has shown promise; however, mechanistic data are lacking. This study assessed the impact of SyncAV on electrical dyssynchrony across various pacing modalities using non-invasive epicardial electrocardiographic imaging (ECGi). Twenty-five patients with left bundle-branch block (median QRS duration (QRSd) 162.7 ms) and intact AV conduction (PR interval 174.0 ms) were prospectively enrolled. ECGi was performed acutely during biventricular pacing with fixed nominal AV delays (BiV) and using SyncAV (optimized for the narrowest QRSd) during: BiV + SyncAV, LV-only single-site (LVSS + SyncAV), MultiPoint pacing (MPP + SyncAV), and LV-only MPP (LVMPP + SyncAV). Dyssynchrony was quantified via ECGi (LV activation time, LVAT; RV activation time, RVAT; LV electrical dispersion index, LVEDi; ventricular electrical uncoupling index, VEU; and biventricular total activation time, VVtat). Intrinsic conduction LVAT (124 ms) was significantly reduced by BiV pacing (109 ms) (P = 0.001) and further reduced by LVSS + SyncAV (103 ms), BiV + SyncAV (103 ms), LVMPP + SyncAV (95 ms), and MPP + SyncAV (90 ms). Intrinsic RVAT (93 ms), VVtat (130 ms), LVEDi (36 ms), VEU (50 ms), and QRSd (163 ms) were reduced by SyncAV across all pacing modes. More patients exhibited minimal LVAT, VVtat, LVEDi, and QRSd with MPP + SyncAV than any other modality. Dynamic AV delay programming targeting fusion with intrinsic conduction significantly reduced dyssynchrony, as quantified by ECGi and QRSd for all evaluated pacing modes. MPP + SyncAV achieved the greatest synchrony overall but not for all patients, highlighting the value of pacing mode individualization during fusion optimization. Dynamic atrioventricular delays targeting fusion with intrinsic conduction reduce electrical dyssynchrony.
- 8 December 2022
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 25 (2) , 536-545
Open AccessElectrocardiographic imaging demonstrates electrical synchrony improvement by dynamic atrioventricular delays in patients with left bundle branch block and preserved atrioventricular conduction
Cardiac resynchronization therapy programmed to dynamically fuse pacing with intrinsic conduction using atrioventricular (AV) timing algorithms (e.g. SyncAV) has shown promise; however, mechanistic data are lacking. This study assessed the impact of SyncAV on electrical dyssynchrony across various pacing modalities using non-invasive epicardial electrocardiographic imaging (ECGi). Twenty-five patients with left bundle-branch block (median QRS duration (QRSd) 162.7 ms) and intact AV conduction (PR interval 174.0 ms) were prospectively enrolled. ECGi was performed acutely during biventricular pacing with fixed nominal AV delays (BiV) and using SyncAV (optimized for the narrowest QRSd) during: BiV + SyncAV, LV-only single-site (LVSS + SyncAV), MultiPoint pacing (MPP + SyncAV), and LV-only MPP (LVMPP + SyncAV). Dyssynchrony was quantified via ECGi (LV activation time, LVAT; RV activation time, RVAT; LV electrical dispersion index, LVEDi; ventricular electrical uncoupling index, VEU; and biventricular total activation time, VVtat). Intrinsic conduction LVAT (124 ms) was significantly reduced by BiV pacing (109 ms) (P = 0.001) and further reduced by LVSS + SyncAV (103 ms), BiV + SyncAV (103 ms), LVMPP + SyncAV (95 ms), and MPP + SyncAV (90 ms). Intrinsic RVAT (93 ms), VVtat (130 ms), LVEDi (36 ms), VEU (50 ms), and QRSd (163 ms) were reduced by SyncAV across all pacing modes. More patients exhibited minimal LVAT, VVtat, LVEDi, and QRSd with MPP + SyncAV than any other modality. Dynamic AV delay programming targeting fusion with intrinsic conduction significantly reduced dyssynchrony, as quantified by ECGi and QRSd for all evaluated pacing modes. MPP + SyncAV achieved the greatest synchrony overall but not for all patients, highlighting the value of pacing mode individualization during fusion optimization. Dynamic atrioventricular delays targeting fusion with intrinsic conduction reduce electrical dyssynchrony.
- Open Access
- 1 May 2021
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 23 (Supplement)
Impact of pacing configuration and right ventricular lead location on dynamic atrioventricular delay optimization
Funding Acknowledgements: Type of funding sources: Private company. Main funding source(s): Abbott Introduction: Automatic adjustment of atrioventricular delay (AVD) with SyncAV has been shown to improve electrical synchronization. However, the effect of pacing configuration and right ventricular (RV) lead location on SyncAV programming is unknown. Purpose: Evaluate the effect of pacing configuration and lead location on SyncAV optimization during biventricular (BiV) and LV-only pacing, with and without MultiPoint Pacing (MPP). Methods: Patients with LBBB and QRS duration (QRSd) ≥ 150 ms scheduled for CRT-P/D device implantation with quadripolar LV lead were enrolled in this prospective study. RV lead location was classified at implant by the operator via fluoroscopy. QRSd was measured post-implant from 12-lead surface ECG by blinded experts during the following pacing modes: intrinsic conduction, BiV (BiV = RV + LV1), MPP (MPP = RV + LV1 + LV2), LV-only single-site (LVSS = LV1 only), and LV-only MPP (LVMPP = LV1 + LV2). For each mode, SyncAV was enabled (e.g. BiV + SyncAV) with the patient-tailored SyncAV offset that minimized QRSd. For BiV and LVSS, LV1 was the latest activating LV cathode; for MPP and LVMPP, LV1 + LV2 were the two LV cathodes with the widest possible separation (≥30mm). All modes used minimal RV-LV and LV1-LV2 delays. Results: Fifty-three patients (68% male, 36% ischemic, 26% ejection fraction, 169 ms intrinsic QRSd) completed device implant and QRSd assessment. RV leads were implanted in either the septum (48%) or apex (52%), according to implanting physician preference. Relative to intrinsic conduction, BiV + SyncAV and MPP + SyncAV reduced QRSd by 23% and 27%, respectively (p < 0.01). LVSS + SyncAV reduced QRSd by 22% (p < 0.01 vs BiV + SyncAV), and LVMPP + SyncAV reduced QRSd by 25% (p < 0.05 vs MPP + SyncAV). RV apex or septum lead location did not have a significant impact on QRS reduction for each pacing configuration. As a percent of PR interval, optimal SyncAV offsets were similar for BiV + SyncAV and MPP + SyncAV (16% vs 13%, p = 0.05), and for LVSS + SyncAV and LVMPP + SyncAV (18% vs 21%, p = 0.46), but were significantly higher for LV-only settings vs. corresponding BiV/MPP settings (p < 0.05 for both pairs). For BiV + SyncAV, apical vs septal RV leads required greater SyncAV offsets (22% vs 11%, p < 0.05). SyncAV offsets also tended to be higher in apical vs septal RV leads for MPP (21% vs 11%), LVSS (20% vs 15%), and LVMPP (25% vs 16%), but without statistical significance. Conclusion: SyncAV improves acute electrical synchronization in CRT patients with LBBB, particularly with patient-specific SyncAV programming. Pacing configuration (RV + LV or LV only, with or without MPP) and RV lead location (apex or septum) could potentially influence optimal SyncAV programming. Abstract Figure.
- 1 May 2021
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 23 (Supplement)
Open AccessImpact of pacing configuration and right ventricular lead location on dynamic atrioventricular delay optimization
Funding Acknowledgements: Type of funding sources: Private company. Main funding source(s): Abbott Introduction: Automatic adjustment of atrioventricular delay (AVD) with SyncAV has been shown to improve electrical synchronization. However, the effect of pacing configuration and right ventricular (RV) lead location on SyncAV programming is unknown. Purpose: Evaluate the effect of pacing configuration and lead location on SyncAV optimization during biventricular (BiV) and LV-only pacing, with and without MultiPoint Pacing (MPP). Methods: Patients with LBBB and QRS duration (QRSd) ≥ 150 ms scheduled for CRT-P/D device implantation with quadripolar LV lead were enrolled in this prospective study. RV lead location was classified at implant by the operator via fluoroscopy. QRSd was measured post-implant from 12-lead surface ECG by blinded experts during the following pacing modes: intrinsic conduction, BiV (BiV = RV + LV1), MPP (MPP = RV + LV1 + LV2), LV-only single-site (LVSS = LV1 only), and LV-only MPP (LVMPP = LV1 + LV2). For each mode, SyncAV was enabled (e.g. BiV + SyncAV) with the patient-tailored SyncAV offset that minimized QRSd. For BiV and LVSS, LV1 was the latest activating LV cathode; for MPP and LVMPP, LV1 + LV2 were the two LV cathodes with the widest possible separation (≥30mm). All modes used minimal RV-LV and LV1-LV2 delays. Results: Fifty-three patients (68% male, 36% ischemic, 26% ejection fraction, 169 ms intrinsic QRSd) completed device implant and QRSd assessment. RV leads were implanted in either the septum (48%) or apex (52%), according to implanting physician preference. Relative to intrinsic conduction, BiV + SyncAV and MPP + SyncAV reduced QRSd by 23% and 27%, respectively (p < 0.01). LVSS + SyncAV reduced QRSd by 22% (p < 0.01 vs BiV + SyncAV), and LVMPP + SyncAV reduced QRSd by 25% (p < 0.05 vs MPP + SyncAV). RV apex or septum lead location did not have a significant impact on QRS reduction for each pacing configuration. As a percent of PR interval, optimal SyncAV offsets were similar for BiV + SyncAV and MPP + SyncAV (16% vs 13%, p = 0.05), and for LVSS + SyncAV and LVMPP + SyncAV (18% vs 21%, p = 0.46), but were significantly higher for LV-only settings vs. corresponding BiV/MPP settings (p < 0.05 for both pairs). For BiV + SyncAV, apical vs septal RV leads required greater SyncAV offsets (22% vs 11%, p < 0.05). SyncAV offsets also tended to be higher in apical vs septal RV leads for MPP (21% vs 11%), LVSS (20% vs 15%), and LVMPP (25% vs 16%), but without statistical significance. Conclusion: SyncAV improves acute electrical synchronization in CRT patients with LBBB, particularly with patient-specific SyncAV programming. Pacing configuration (RV + LV or LV only, with or without MPP) and RV lead location (apex or septum) could potentially influence optimal SyncAV programming. Abstract Figure.
- 1 June 2020
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 22 (Supplement)
43Dynamic atrioventricular delay achieves superior electrical synchrony when pacing both ventricles rather than left ventricle alone
Funding Acknowledgements: Abbott Introduction: Automatic adjustment of atrioventricular delay (AVD) with SyncAV has been shown to improve electrical synchronization when pacing one or two sites in the left ventricle together with the right ventricle. However, it is unknown if the same benefit can be gained by using SyncAV while pacing only the left ventricle without right ventricular pacing. Purpose: Evaluate the acute improvement in electrical synchrony provided by SyncAV with and without MultiPoint Pacing (MPP) during biventricular (BiV) and LV only pacing. Methods: Patients with LBBB and QRS duration (QRSd) ≥ 150 ms scheduled for CRT-P/D device implantation with quadripolar LV lead were enrolled in this prospective study. QRSd was measured post-implant from 12-lead surface electrograms by blinded experts during the following pacing configurations: intrinsic conduction, conventional BiV (BiV = RV + LV1), MPP (MPP = RV + LV1 + LV2), LV-only single-site (LVSS = LV1 only), and LV-only MPP (LVMPP = LV1 + LV2). For each pacing mode, SyncAV was enabled (e.g. BiV + SyncAV) with the patient-tailored SyncAV offset that minimized QRSd. As an additional reference, QRSd during BiV was also measured using the nominal static AVD (paced/sensed AVD = 140/110 ms). BiV and LVSS pacing used the latest activating LV cathode, whereas MPP and LVMPP used the two LV cathodes with the widest possible separation (>30mm). All configurations used the minimum programmable RV-LV and LV1-LV2 delays. Results: Thirty-five patients (78% male, 33% ischemic, 26% ejection fraction, 165 ms intrinsic QRSd) completed device implant and QRSd assessment. Relative to intrinsic conduction, BiV with nominal AVD reduced the QRSd by 17.5% (p < 0.001 vs intrinsic). Enabling SyncAV with a patient-optimized offset significantly improved QRSd reduction. BiV + SyncAV reduced QRSd by 25.2% (p < 0.001 vs. BiV). The greatest QRSd reduction of 28.9% was achieved by MPP + SyncAV (p < 0.01 vs. BiV + SyncAV). Single- and multi-site LV-only pacing reduced QRSd significantly less than corresponding biventricular modes. LVSS + SyncAV reduced QRSd by 22.5% (p < 0.05 vs. BiV + SyncAV), and LVMPP + SyncAV reduced QRSd by 24.3% (p < 0.05 vs. MPP + SyncAV). As a percent of PR interval, optimal SyncAV offsets were similar for BiV + SyncAV (median: 13%, mean: 17%) vs. MPP + SyncAV (median: 13%, mean 16%, p = 0.35 vs. BiV + SyncAV), and similar for LVSS + SyncAV (median: 20%, mean: 28%) and LVMPP + SyncAV (median: 23%, mean: 26%, p = 0.35 vs. LVSS + SyncAV), but were significantly higher for LV-only settings vs. corresponding BiV/MPP settings (p < 0.01 for both pairs). Conclusion: Greater improvement in electrical synchrony using SyncAV was observed when right ventricular pacing was included with left ventricular pacing. Additional benefit was gained by the addition of a second left ventricular pacing site with MPP in combination with SyncAV in both biventricular and LV only pacing modes. Abstract Figure.
- 1 June 2020
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 22 (Supplement)
43Dynamic atrioventricular delay achieves superior electrical synchrony when pacing both ventricles rather than left ventricle alone
Funding Acknowledgements: Abbott Introduction: Automatic adjustment of atrioventricular delay (AVD) with SyncAV has been shown to improve electrical synchronization when pacing one or two sites in the left ventricle together with the right ventricle. However, it is unknown if the same benefit can be gained by using SyncAV while pacing only the left ventricle without right ventricular pacing. Purpose: Evaluate the acute improvement in electrical synchrony provided by SyncAV with and without MultiPoint Pacing (MPP) during biventricular (BiV) and LV only pacing. Methods: Patients with LBBB and QRS duration (QRSd) ≥ 150 ms scheduled for CRT-P/D device implantation with quadripolar LV lead were enrolled in this prospective study. QRSd was measured post-implant from 12-lead surface electrograms by blinded experts during the following pacing configurations: intrinsic conduction, conventional BiV (BiV = RV + LV1), MPP (MPP = RV + LV1 + LV2), LV-only single-site (LVSS = LV1 only), and LV-only MPP (LVMPP = LV1 + LV2). For each pacing mode, SyncAV was enabled (e.g. BiV + SyncAV) with the patient-tailored SyncAV offset that minimized QRSd. As an additional reference, QRSd during BiV was also measured using the nominal static AVD (paced/sensed AVD = 140/110 ms). BiV and LVSS pacing used the latest activating LV cathode, whereas MPP and LVMPP used the two LV cathodes with the widest possible separation (>30mm). All configurations used the minimum programmable RV-LV and LV1-LV2 delays. Results: Thirty-five patients (78% male, 33% ischemic, 26% ejection fraction, 165 ms intrinsic QRSd) completed device implant and QRSd assessment. Relative to intrinsic conduction, BiV with nominal AVD reduced the QRSd by 17.5% (p < 0.001 vs intrinsic). Enabling SyncAV with a patient-optimized offset significantly improved QRSd reduction. BiV + SyncAV reduced QRSd by 25.2% (p < 0.001 vs. BiV). The greatest QRSd reduction of 28.9% was achieved by MPP + SyncAV (p < 0.01 vs. BiV + SyncAV). Single- and multi-site LV-only pacing reduced QRSd significantly less than corresponding biventricular modes. LVSS + SyncAV reduced QRSd by 22.5% (p < 0.05 vs. BiV + SyncAV), and LVMPP + SyncAV reduced QRSd by 24.3% (p < 0.05 vs. MPP + SyncAV). As a percent of PR interval, optimal SyncAV offsets were similar for BiV + SyncAV (median: 13%, mean: 17%) vs. MPP + SyncAV (median: 13%, mean 16%, p = 0.35 vs. BiV + SyncAV), and similar for LVSS + SyncAV (median: 20%, mean: 28%) and LVMPP + SyncAV (median: 23%, mean: 26%, p = 0.35 vs. LVSS + SyncAV), but were significantly higher for LV-only settings vs. corresponding BiV/MPP settings (p < 0.01 for both pairs). Conclusion: Greater improvement in electrical synchrony using SyncAV was observed when right ventricular pacing was included with left ventricular pacing. Additional benefit was gained by the addition of a second left ventricular pacing site with MPP in combination with SyncAV in both biventricular and LV only pacing modes. Abstract Figure.
- 1 June 2020
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 22 (Supplement)
841Multi-center clinical experience with the usage of implantable pulse generators for permanent his bundle pacing
Funding Acknowledgements: Abbott Introduction: His Bundle pacing (HBP) offers a more physiologic pacing approach to maintain electrical synchrony. Permanent HBP has emerged as a feasible and safe alternative to traditional pacemaker therapy and cardiac resynchronization therapy (CRT) with clinical and electrophysiological advantages. However, traditional implantable pulse generators (IPGs) have been used for HBP without supporting algorithms developed for HBP. Objective: To assess a multi-center clinical experience with the usage of IPGs for permanent HBP and to identify the needs for HBP specific device algorithms. Methods: Patients from 6 centers worldwide with a permanent HBP lead and an existing Abbott pacemaker, defibrillator, or CRT device were enrolled in this study. Device data and 12-lead surface ECG were collected simultaneously during device interrogation at a follow-up visit. HBP capture types at different pacing amplitudes were adjudicated using 12-lead ECG. Bundle branch block (BBB) correction by HBP was defined as QRS duration ≤130 ms or narrowing by >20%. Amplitudes of atrial and ventricular components on the HBP lead from both unipolar and bipolar sensing configurations were measured. Amplitudes of atrial component ≥ 0.5 mV on HB sensing EGMs were measured and considered as having risk of atrial oversensing. Results: A total of 133 patients (75 ± 10 yrs, 92 male) were enrolled and completed study data collection post implant (median: 48, range: 0-3110 days). Patient characteristics, IPG type, and HBP lead connections were shown in the table. Dual-chamber pacemaker with HBP lead connected to V port was the most popular (65%) configuration. In non-BBB patients, pacing thresholds for selective HB (n = 44), non-selective HB (n = 54), and myocardial capture (n = 21) were 1.5 ± 1.2, 2.9 ± 2.0, 1.4 ± 1.5 V, respectively, at pulse width of 0.8 ± 0.4 ms. In BBB patients, LBBB and RBBB were corrected in 10/23 (43%) and 12/27 (44%) patients with pacing thresholds of 3.5 ± 2.4 and 2.1 ± 2.0 V, respectively, at pulse width of 0.8 ± 0.3 ms. AutoCapture™ algorithm was tested in 63 patients and recommended to be OFF in 28 (44%) patients. EGMs during intrinsic AV conduction were collected in 86 patients. A risk of atrial oversensing was identified in 24 (28%) and 27 (31%) patients during bipolar and unipolar sensing, respectively, and in 17 (20%) patients during both configurations. The average amplitude of the atrial and ventricular components on the HB lead EGM were 2.1 ± 2 and 6.0 ± 5.8 mV during bipolar sensing and 1.3 ± 1.2 and 6.3 ± 6.5 mV during unipolar sensing, respectively. Five (6%) patients had A/V amplitude ratios higher than 1. Conclusions: Currently, various device configurations are used to overcome the fact that IPGs are not designed for HBP. Additionally, HBP presents unique challenges to ensure appropriate capture and sensing beyond traditional RV pacing. HBP specific device algorithms are needed to ensure correct IPG usage and facilitate device programming. Abstract Figure.
- 1 June 2020
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 22 (Supplement)
841Multi-center clinical experience with the usage of implantable pulse generators for permanent his bundle pacing
Funding Acknowledgements: Abbott Introduction: His Bundle pacing (HBP) offers a more physiologic pacing approach to maintain electrical synchrony. Permanent HBP has emerged as a feasible and safe alternative to traditional pacemaker therapy and cardiac resynchronization therapy (CRT) with clinical and electrophysiological advantages. However, traditional implantable pulse generators (IPGs) have been used for HBP without supporting algorithms developed for HBP. Objective: To assess a multi-center clinical experience with the usage of IPGs for permanent HBP and to identify the needs for HBP specific device algorithms. Methods: Patients from 6 centers worldwide with a permanent HBP lead and an existing Abbott pacemaker, defibrillator, or CRT device were enrolled in this study. Device data and 12-lead surface ECG were collected simultaneously during device interrogation at a follow-up visit. HBP capture types at different pacing amplitudes were adjudicated using 12-lead ECG. Bundle branch block (BBB) correction by HBP was defined as QRS duration ≤130 ms or narrowing by >20%. Amplitudes of atrial and ventricular components on the HBP lead from both unipolar and bipolar sensing configurations were measured. Amplitudes of atrial component ≥ 0.5 mV on HB sensing EGMs were measured and considered as having risk of atrial oversensing. Results: A total of 133 patients (75 ± 10 yrs, 92 male) were enrolled and completed study data collection post implant (median: 48, range: 0-3110 days). Patient characteristics, IPG type, and HBP lead connections were shown in the table. Dual-chamber pacemaker with HBP lead connected to V port was the most popular (65%) configuration. In non-BBB patients, pacing thresholds for selective HB (n = 44), non-selective HB (n = 54), and myocardial capture (n = 21) were 1.5 ± 1.2, 2.9 ± 2.0, 1.4 ± 1.5 V, respectively, at pulse width of 0.8 ± 0.4 ms. In BBB patients, LBBB and RBBB were corrected in 10/23 (43%) and 12/27 (44%) patients with pacing thresholds of 3.5 ± 2.4 and 2.1 ± 2.0 V, respectively, at pulse width of 0.8 ± 0.3 ms. AutoCapture™ algorithm was tested in 63 patients and recommended to be OFF in 28 (44%) patients. EGMs during intrinsic AV conduction were collected in 86 patients. A risk of atrial oversensing was identified in 24 (28%) and 27 (31%) patients during bipolar and unipolar sensing, respectively, and in 17 (20%) patients during both configurations. The average amplitude of the atrial and ventricular components on the HB lead EGM were 2.1 ± 2 and 6.0 ± 5.8 mV during bipolar sensing and 1.3 ± 1.2 and 6.3 ± 6.5 mV during unipolar sensing, respectively. Five (6%) patients had A/V amplitude ratios higher than 1. Conclusions: Currently, various device configurations are used to overcome the fact that IPGs are not designed for HBP. Additionally, HBP presents unique challenges to ensure appropriate capture and sensing beyond traditional RV pacing. HBP specific device algorithms are needed to ensure correct IPG usage and facilitate device programming. Abstract Figure.
- 1 June 2020
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 22 (Supplement)
862Syncav with multipoint pacing improves acute left ventricular hemodynamics
Funding Acknowledgements: Abbott Introduction: SyncAV has been shown to improve electrical synchronization by automatically adjusting atrioventricular delay (AVD) according to the intrinsic atrioventricular conduction time. Additional incremental electrical synchronization may be gained by the addition of second left ventricular (LV) pulse with MultiPoint Pacing (MPP). While the electrical synchronization benefits of SyncAV have been previously explored, there has been no assessment of the acute hemodynamic impact of SyncAV with or without MPP. Objective: Evaluate the acute LV hemodynamic impact of SyncAV with and without MPP. Methods: Heart failure patients with LBBB and QRS duration (QRSd) > 140 ms undergoing CRT-P/D implant with a quadripolar LV lead were enrolled in this prospective study. A guidewire or catheter with pressure transducer was placed in the LV chamber and the maximum pressure change (dP/dtmax) was recorded during the following pacing modes: intrinsic conduction, conventional biventricular pacing with SyncAV (BiV + SyncAV), and MPP with SyncAV (MPP + SyncAV). Twelve-lead surface ECG was used to determine the patient-tailored SyncAV offset that minimized QRSd. Results: Twenty-seven patients (67% male, 44% ischemic, 30 ± 7% ejection fraction) completed the acute recordings. Relative to the intrinsic QRSd of 163 ms, BiV + SyncAV reduced QRSd by 21.5% to 124 ms (p < 0.001 vs. intrinsic) and MPP + SyncAV reduced QRSd by 26.6% to 120 ms (p < 0.05 vs. BiV + SyncAV). Beyond electrical synchronization, SyncAV significantly improved acute hemodynamics. Relative to the intrinsic dP/dtmax of 842 mmHg/s, BiV + SyncAV elevated dP/dtmax by 6.3% to 900 mmHg/s (p < 0.001 vs. intrinsic) and MPP + SyncAV elevated dP/dtmax by 8.8% to 926 mmHg/s (p < 0.005 vs. BiV + SyncAV). Despite both QRSd and dP/dtmax improvement with SyncAV and MPP, correlation between electrical and hemodynamic measurements was poor (R2 = 0.0 for BiV + SyncAV, R2 = 0.1 for MPP + SyncAV). Conclusion: SyncAV may significantly improve acute LV hemodynamics in addition to electrical synchrony in LBBB patients. Further incremental improvement was achieved by combining SyncAV with MPP. Abstract Figure.
- 1 June 2020
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 22 (Supplement)
862Syncav with multipoint pacing improves acute left ventricular hemodynamics
Funding Acknowledgements: Abbott Introduction: SyncAV has been shown to improve electrical synchronization by automatically adjusting atrioventricular delay (AVD) according to the intrinsic atrioventricular conduction time. Additional incremental electrical synchronization may be gained by the addition of second left ventricular (LV) pulse with MultiPoint Pacing (MPP). While the electrical synchronization benefits of SyncAV have been previously explored, there has been no assessment of the acute hemodynamic impact of SyncAV with or without MPP. Objective: Evaluate the acute LV hemodynamic impact of SyncAV with and without MPP. Methods: Heart failure patients with LBBB and QRS duration (QRSd) > 140 ms undergoing CRT-P/D implant with a quadripolar LV lead were enrolled in this prospective study. A guidewire or catheter with pressure transducer was placed in the LV chamber and the maximum pressure change (dP/dtmax) was recorded during the following pacing modes: intrinsic conduction, conventional biventricular pacing with SyncAV (BiV + SyncAV), and MPP with SyncAV (MPP + SyncAV). Twelve-lead surface ECG was used to determine the patient-tailored SyncAV offset that minimized QRSd. Results: Twenty-seven patients (67% male, 44% ischemic, 30 ± 7% ejection fraction) completed the acute recordings. Relative to the intrinsic QRSd of 163 ms, BiV + SyncAV reduced QRSd by 21.5% to 124 ms (p < 0.001 vs. intrinsic) and MPP + SyncAV reduced QRSd by 26.6% to 120 ms (p < 0.05 vs. BiV + SyncAV). Beyond electrical synchronization, SyncAV significantly improved acute hemodynamics. Relative to the intrinsic dP/dtmax of 842 mmHg/s, BiV + SyncAV elevated dP/dtmax by 6.3% to 900 mmHg/s (p < 0.001 vs. intrinsic) and MPP + SyncAV elevated dP/dtmax by 8.8% to 926 mmHg/s (p < 0.005 vs. BiV + SyncAV). Despite both QRSd and dP/dtmax improvement with SyncAV and MPP, correlation between electrical and hemodynamic measurements was poor (R2 = 0.0 for BiV + SyncAV, R2 = 0.1 for MPP + SyncAV). Conclusion: SyncAV may significantly improve acute LV hemodynamics in addition to electrical synchrony in LBBB patients. Further incremental improvement was achieved by combining SyncAV with MPP. Abstract Figure.
- Open Access
- 1 March 2018
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 20 (suppl_1) , i116-i117
686Automatic AVD Programming by SyncAV Improves Electrical Synchronization in a Multicenter Study of CRT Patients
Introduction: SyncAV, a new CRT feature that continually programs atrioventricular delay (AVD) shorter than the intrinsic AV conduction time (by a default or programmable offset), may improve electrical synchrony by fusion of intrinsic, LV-paced, and RV-paced activation wavefronts. However, it is not known how the degree of synchronization achieved depends on the LV pacing vector selected.
- 1 March 2018
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 20 (suppl_1) , i116-i117
Open Access686Automatic AVD Programming by SyncAV Improves Electrical Synchronization in a Multicenter Study of CRT Patients
Introduction: SyncAV, a new CRT feature that continually programs atrioventricular delay (AVD) shorter than the intrinsic AV conduction time (by a default or programmable offset), may improve electrical synchrony by fusion of intrinsic, LV-paced, and RV-paced activation wavefronts. However, it is not known how the degree of synchronization achieved depends on the LV pacing vector selected.