RARoberto Arpesani

Roberto Arpesani

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Roberto Arpesani has a total of 32 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Midterm follow-up after embolization of intracranial aneurysms proximal to the circle of Willis with the Silk Vista flow diverter: the I-MAMA registry

    by Valerio Da Ros, Federico Sabuzi, Francesco D’aRgento, Alessandro Pedicelli, Vladimir Gavrilovic, Massimo Sponza, Francesca Di Giuliano, Francesco Biraschi, Marta Iacobucci, Giovanni Grillea, et al.

    Purpose: The aim of this registry was to assess technical success, procedural safety and mid- to long-term follow-up results of the Silk Vista “Mama” (SVM) flow diverter (BALT, Montmorency, France) for the treatment of proximal intracranial aneurysms. Methods: Between August 2020 and March 2022, data from nine Italian neurovascular centres were collected. Data included patients’ clinical presentation, aneurysms’ size, location and status, technical details, overall complications and mid- to long-term angiographic follow-up. Results: Forty-eight aneurysms in 48 patients were treated using the SVM. Most aneurysms were small (≤ 10 mm: no. 29, 60%) and unruptured (no. 31, 65%); 13 aneurysms were recurrent after coiling or clipping. 37/48 aneurysms involved the internal carotid artery (77%). Optimal opening and complete wall apposition of the device were achieved in 46 out of 48 cases (96%). Four intra- or periprocedural complications occurred (two thrombotic complications successfully resolved, one cerebellar ischemia, one perirenal hematoma), without new neurological deficit. No significant intra-stent stenosis or stent displacement was observed during follow-up. No FD-related morbidity nor mortality was reported. At midterm (6–12 months) to long-term (> 12 months) follow-up, complete aneurysm occlusion (OKM D) was achieved in 76% of cases. Eighty-eight percent of patients had complete aneurysm occlusion or entry remnant (OKM D + C). Conclusions: Our experience suggests that the new generation of low-profile SVM flow diverter for the treatment of proximal intracranial aneurysms is safe and effective, with low rates of intraprocedural complications and acceptable mid- to long-term occlusion rate.


  • Open Access

    Flow-diverter treatment for renal artery aneurysms: One-year follow-up of a multicentric preliminary experience

    by Vittorio Semeraro, Roberto Arpesani, Giuseppina della Malva, Fulvio Gasparrini, Sofia Vidali, Maria Porzia Ganimede, Antonio Marrazzo, Francesco Rosella, Francesco Biraschi, Roberto Gandini, et al.

    Renal artery aneurysms (RAAs) are rare in the general population, although the true incidence and natural history remain elusive. Conventional endovascular therapies such as coil embolization or covered stent graft may cause side branches occlusion, leading to organ infarction. Flow diverters (FDs) have been first designed to treat cerebrovascular aneurysms, but their use may be useful to treat complex RAAs presenting side branches arising from the aneurysmal sac. We aimed to evaluate the mid-term follow-up (FUP) safety and efficacy of FDs during the treatment of complex RAAs. Between November 2019 and April 2020, 7 RAAs were identified in 7 patients (4 men, 3 women; age range 55-82 years; median 67 years) and treated by FDs. Procedural details, complications, morbidity and mortality, aneurysm occlusion, and segmental artery patency were retrospectively reviewed. Twelve months of computed tomography angiography (CTA) FUP was evaluated for all cases. Deployment of FDs was successful in all cases. One intraprocedural technical complication was encountered with one FD felt down into aneurism sac which requiring additional telescopic stenting. One case at 3 months CTA FUP presented the same complication, requiring the same rescue technique. At 12 months CTA FUP, 5 cases of size shrinkage and 2 cases of stable size were documented. No rescue surgery or major intraprocedural or mid-term FUP complication was seen. Complex RAAs with 2 or more side branches can be safely treated by FD. FD efficacy for RAA needs further validation at long-term FUP by additional large prospective studies.