SCSergio Cánovas-López

Sergio Cánovas-López

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Sergio Cánovas-López has a total of 22 co-authors. Here are the top co-authors by number of shared publications:

  • José María Arribas

    Department of Cardiovascular Surgery, Virgen de la Arrixaca University Hospital/Research and Development in Cardiovascular Surgery Group, Biomedical Research Institute of Murcia Pascual Parrilla–IMIB, Murcia, Spain

    2 shared publications
  • Juan Blanco-Morillo

    Perfusion and Extracorporeal Therapies in Cardiovascular Surgery Department, Arrixaca University Hospital/Research and Development in Cardiovascular Surgery Group, Biomedical Research Institute of Murcia Pascual Parrilla–IMIB, Murcia, Spain

    2 shared publications
  • Alicia Verdú-Verdú

    Cardiovascular Surgery, Extracorporeal Therapies Group, Virgen de la Arrixaca University Hospital, Murcia, Spain

    1 shared publication
  • Angel Sornichero-Caballero

    Cardiovascular Surgery, Extracorporeal Therapies Group, Virgen de la Arrixaca University Hospital, Murcia, Spain

    1 shared publication
  • Antonio García-Candel

    Department of Cardiovascular Anesthesiology, Arrixaca University Hospital/Biomedical Research Institute of Murcia Pascual Parrilla–IMIB, Murcia, Spain

    1 shared publication
  • Daniel Vicente Morillo-Cuadrado

    Network-Based Biomedical Research Consortium, Area of Mental Health (CiberSAM), Carlos III Health Institute, Madrid, Spain

    1 shared publication

Latest Publications

  • Open Access

    Initial Experience With Del Nido Cardioplegia in Adult Cardiac Transplantation

    by Ramón Aranda-Domene, Juan Blanco-Morillo, María José Alcaraz-García, José María Arribas-Leal, Francisco Gutiérrez-García, Julio García-Puente, Iris Garrido-Bravo, Francisco Pastor-Pérez, Rubén Jara-Rubio, Mario Royo-Villanova, et al.

    Del Nido Cardioplegia (DNC) is widely used in nontransplant cardiac surgery, but its role as a preservation solution in cardiac transplantation is unclear. We conducted a retrospective observational study of 61 patients undergoing heart transplant between January 2015 and December 2023. Only recipients with locally procured donor hearts were included. Recipients were grouped according to the type of preservative solution: DNC (n = 33) versus control (crystalloid + cold blood cardioplegia; n = 28). Patients in the DNC group were older and more frequently received hearts from donation after circulatory death. The Del Nido Cardioplegia group had lower troponin-T release at 48 hours (median [interquartile range {IQR}]: 1,062 [820] vs . 700 [345]; p = 0.03). Compared with the DNC, control group was related with longer ischemic (median [IQR]: 65 [55–83] vs . 80 [70.2–92.7] minutes; p = 0.002) and bypass times (median [IQR]: 90 [73.5–112] vs . 108 [97–118] minutes; p = 0.001). On-pump blood glucose levels and need for electrical defibrillation were lower with DNC. In heart transplantation using locally procured grafts, DNC appears to be a feasible preservation strategy. Del Nido Cardioplegia was associated with shorter operative times and lower troponin release in our initial experience. Further studies should be performed to confirm these promising results.

  • Open Access

    Hematic Antegrade Repriming Reduces Emboli on Cardiopulmonary Bypass: A Randomized Controlled Trial

    by Juan Blanco-Morillo, Diego Salmerón Martínez, Daniel Vicente Morillo-Cuadrado, Jose María Arribas-Leal, Luc Puis, Alicia Verdú-Verdú, Mercedes Martínez-Molina, Encarnación Tormos-Ruiz, Angel Sornichero-Caballero, Pablo Ramírez-Romero, et al.

    Particulate and gaseous microemboli (GME) are side effects of cardiac surgery that interfere with postoperative recovery by causing endothelial dysfunction and vascular blockages. GME sources during surgery are multiple, and cardiopulmonary bypass (CPB) is contributory to this embolic load. Hematic antegrade repriming (HAR) is a novel procedure that combines the benefits of repriming techniques with additional measures, by following a standardized procedure to provide a reproducible hemodilution of 300 ml. To clarify the safety of HAR in terms of embolic load delivery, a prospective and controlled study was conducted, by applying Doppler probes to the extracorporeal circuit, to determine the number and volume of GME released during CPB. A sample of 115 patients (n = 115) was considered for assessment. Both groups were managed under strict normothermia, and similar clinical conditions and protocols, receiving the same open and minimized circuit. Significant differences in GME volume delivery (control group [CG] = 0.28 ml vs. HAR = 0.08 ml; p = 0.004) and high embolic volume exposure (>1 ml) were found between the groups (CG = 30.36% vs. HAR = 4.26%; p = 0.001). The application of HAR did not represent an additional embolic risk and provided a four-fold reduction in the embolic volume delivered to the patient (coefficient, 0.24; 95% CI, 0.08–0.72; p = 0.01), which appears to enhance GME clearance of the oxygenator before CPB initiation.