NNNora Fernández Navas

Nora Fernández Navas

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Nora Fernández Navas has a total of 34 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Pitting corrosion mechanisms of Ti-Cu-(Pd-) based metallic glasses in simulated physiological solution

    by Viktoriia Shtefan, Nora Fernández Navas, Ivan Kaban, Martin Hantusch, Annett Gebert


  • Electrochemical Behavior as an Indicator of Functional Performance Control in Bulk Metallic Glasses

    by Viktoriia Shtefan, Nora Fernández Navas, Annett Gebert

    Ti-Cu-(Pd) bulk metallic glasses (BMGs) offer high strength-to-stiffness ratios, but their biocompatibility is compromised by their high copper content, which affects cytocompatibility and corrosion resistance. Two BMGs, Ti47Zr7.5Cu38Fe2.5Sn2Si1Ag2 and Ti40Zr10Cu34Pd14Sn2, were studied in a phosphate buffer solution (PBS, pH 7.4, 37 °C) in free corrosion and anodic polarisation conditions. The first alloy exhibited poor passive film stability and pit repassivation ability, whereas the second alloy demonstrated higher pitting resistance with corrosion products enriched in Cu, Zr, and Pd. To improve biocompatibility, both alloys underwent a pseudo-dealloying process to create nanoporous Ti/Zr oxide layers. This treatment suppressed chloride-induced pitting, achieving corrosion resistance comparable to that of cp-Ti and rendering the alloy promising for use in implants.

  • Open Access

    Electrochemical Surface Nanostructuring of Ti47Cu38Fe2.5Zr7.5Sn2Si1Ag2 Metallic Glass for Improved Pitting Corrosion Resistance

    by Nora Fernández‐Navas, Christine Joy Querebillo, Kirti Tiwari, Martin Hantusch, Viktoriia Shtefan, Nicolás Pérez, Paola Rizzi, Martina Zimmermann, Annett Gebert

    Ti‐based bulk metallic glasses are envisioned for human implant applications. Yet, while their elevated Cu content is essential for a high glass‐forming ability, it poses biocompatibility issues, necessitating a reduction in near‐surface regions. To address this, surface treatments that simultaneously generate protective and bioactive states, based on nanostructured Ti and Zr‐oxide layers are proposed. An electrochemical pseudo‐dealloying process using the bulk glass‐forming Ti47Cu38Fe2.5Zr7.5Sn2Si1Ag2 alloy is defined. Melt‐spun ribbons are immersed in hot concentrated nitric acid solution, monitoring the anodic polarization behavior. From the current density transient measurements, together with surface studies (field‐emission scanning electron microscopy, transmission electron microscopy, and Auger electron spectroscopy), the surface reactions are described. This nanostructuring process is divided into three stages: passivation, Cu dissolution, and slow oxide growth, leading to homogenous nanoporous and ligament structures. By tuning the applied potential, the pore and ligament sizes, and thickness values are adjusted. According to X‐ray photoelectron spectroscopy, these nanoporous structures are Ti and Zr‐oxides rich in hydrous and nonhydrous states. In a simulated physiological solution, for those treated glassy alloy samples, complete suppression of chloride‐induced pitting corrosion in the anodic regime of water stability is achieved. This high corrosion resistance is similar to that of clinically used cp‐Ti.


  • Open Access

    Porous Inorganic Nanomaterials: Their Evolution towards Hierarchical Porous Nanostructures

    by Anitta Jose, Tom Mathew, Nora Fernández-Navas, Christine Joy Querebillo

    The advancement of both porous materials and nanomaterials has brought about porous nanomaterials. These new materials present advantages both due to their porosity and nano-size: small size apt for micro/nano device integration or in vivo transport, large surface area for guest/target molecule adsorption and interaction, porous channels providing accessibility to active/surface sites, and exposed reactive surface/active sites induced by uncoordinated bonds. These properties prove useful for the development of different porous composition types (metal oxides, silica, zeolites, amorphous oxides, nanoarrays, precious metals, non-precious metals, MOFs, carbon nanostructures, MXenes, and others) through different synthetic procedures—templating, colloidal synthesis, hydrothermal approach, sol-gel route, self-assembly, dealloying, galvanostatic replacement, and so—for different applications, such as catalysis (water-splitting, etc.), biosensing, energy storage (batteries, supercapacitors), actuators, SERS, and bio applications. Here, these are presented according to different material types showing the evolution of the structure design and development towards the formation of hierarchical porous structures, emphasizing that the formation of porous nanostructures came about out of the desire and need to form hierarchical porous nanostructures. Common trends observed across these different composition types include similar (aforementioned) applications and the use of porous nanomaterials as templates/precursors to create novel ones. Towards the end, a discussion on the link between technological advancements and the development of porous nanomaterials paves the way to present future perspectives on these nanomaterials and their hierarchical porous architectures. Together with a summary, these are given in the conclusion.


  • Open Access

    Surface modification of Ti40Cu40Zr11Fe3Sn3Ag3 amorphous alloy for enhanced biocompatibility in implant applications

    by Kirti Tiwari, Andreu Blanquer, Cristina Pavan, Maura Tomatis, Nora Fernandez Navas, Federico Scaglione, Gianluca Fiore, Francesco Turci, Carme Nogués, Paola Rizzi


  • Open Access

    Acid Treatments of Ti-Based Metallic Glasses for Improving Corrosion Resistance in Implant Applications

    by Nora Fernández-Navas, Viktoriia Shtefan, Martin Hantusch, Annett Gebert

    Ti-based bulk metallic glasses are promising materials for metallic bone implants, mainly due to their mechanical biofunctionality. A major drawback is their limited corrosion resistance, with high sensitivity to pitting. Thus, effective surface treatments for these alloys must be developed. This work investigates the electrochemical treatment feasibility of nitric acid (HNO3) solution for two bulk glass-forming alloys. The surface states obtained at different anodic potentials are characterized with electron microscopy and Auger electron spectroscopy. The corrosion behavior of the treated glassy alloys is analyzed via comparison to non-treated states in phosphate-buffered saline solution (PBS) at 37 °C. For the glassy Ti47Zr7.5Cu38Fe2.5Sn2Si1Ag2 alloy, the pre-treatment causes pseudo-dealloying, with a transformation from naturally passivated surfaces to Ti- and Zr-oxide nanoporous layers and Cu-species removal from the near-surface regions. This results in effective suppression of chloride-induced pitting in PBS. The glassy Ti40Zr10Cu34Pd14Sn2 alloy shows lower free corrosion activity in HNO3 and PBS due to Pd stabilizing its strong passivity. However, this alloy undergoes pitting under anodic conditions. Surface pre-treatment results in Cu depletion but causes enrichment of Pd species and non-homogeneous surface oxidation. Therefore, for this glassy alloy, pitting cannot be completely inhibited in PBS. Concluding, anodic treatments in HNO3 are more suitable for Pd-free glassy Ti-based alloys.


  • Open Access

    Surface Modified β-Ti-18Mo-6Nb-5Ta (wt%) Alloy for Bone Implant Applications: Composite Characterization and Cytocompatibility Assessment

    by Michael Escobar, Oriol Careta, Nora Fernández Navas, Aleksandra Bartkowska, Ludovico Andrea Alberta, Jordina Fornell, Pau Solsona, Thomas Gemming, Annett Gebert, Elena Ibáñez, et al.

    Commercially available titanium alloys such as Ti-6Al-4V are established in clinical use as load-bearing bone implant materials. However, concerns about the toxic effects of vanadium and aluminum have prompted the development of Al- and V-free β-Ti alloys. Herein, a new alloy composed of non-toxic elements, namely Ti-18Mo-6Nb-5Ta (wt%), has been fabricated by arc melting. The resulting single β-phase alloy shows improved mechanical properties (Young’s modulus and hardness) and similar corrosion behavior in simulated body fluid when compared with commercial Ti-6Al-4V. To increase the cell proliferation capability of the new biomaterial, the surface of Ti-18Mo-6Nb-5Ta was modified by electrodepositing calcium phosphate (CaP) ceramic layers. Coatings with a Ca/P ratio of 1.47 were obtained at pulse current densities, −jc, of 1.8–8.2 mA/cm2, followed by 48 h of NaOH post-treatment. The thickness of the coatings has been measured by scanning electron microscopy from an ion beam cut, resulting in an average thickness of about 5 μm. Finally, cytocompatibility and cell adhesion have been evaluated using the osteosarcoma cell line Saos-2, demonstrating good biocompatibility and enhanced cell proliferation on the CaP-modified Ti-18Mo-6Nb-5Ta material compared with the bare alloy, even outperforming their CaP-modified Ti-6-Al-4V counterparts.