RYRongjun Yu

Rongjun Yu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Rongjun Yu has a total of 14 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    2D Ti3C2Tx MXene nanozymes based electrochemical MicroRNA biosensor and application to early diagnosis of sepsis-associated acute kidney injury

    by Xiangyu Deng, Xia Zheng, Anyi Chen, Yuqing Li, Siling Chen, Jiangling Wu, Jianjiang Xue, Rongjun Yu, Min Zhao, Jingfu Qiu

    MicroRNA detection-based molecular diagnostic methods offer a favorable pathway for the early diagnosis of sepsis-associated acute kidney injury (SA-AKI), which is crucial for reducing mortality and improving patient outcomes. In this work, a highly sensitive electrochemical biosensor was fabricated for the determination of serum miR-452-5p, an emerging biomarker for SA-AKI, leveraging the novel Ti 3 C 2 T x MXene nanozymes and catalytic hairpin assembly isothermal amplification. Surprisingly, the two-dimensional Ti 3 C 2 T x MXene nanozymes demonstrated remarkable electro-catalytic activity towards choline, wihch was attributed to the strong adsorption interaction between the oxygen atoms on the Ti 3 C 2 T x MXene surface and the hydroxyl group of choline. Based on above-mentioned characteristic of Ti 3 C 2 T x MXene nanozymes, a cascading catalytic amplification strategy by integrating Ti 3 C 2 T x MXene with alkaline phosphatase using phosphorylcholine chloride as the substrate was designed, thereby achieving highly efficient electrochemical signal amplification. The electrochemical biosensing approach exhibited remarkable sensitivity for miR-452-5p detection, with a linear response over a concentration range from 0.1 fM to 10 nM and a low detection limit of 0.09 fM. Additionally, the developed electrochemical biosensor for direct serum miR-452-5p detection present a diagnostic efficiency of 96% in clinical samples analysis, highlighting its strong potential for the early detection and risk assessment of SA-AKI. Graphical Abstract


  • Open Access

    Electrochemical Biosensor for Detection of the CYP2C19*2 Allele Based on Exonuclease Ⅲ

    by Siling Chen, Rongjun Yu, Ying Li, Jiangling Wu, Jingfu Qiu, Xinyi Huang, Jianjiang Xue

    Currently, the therapeutic effect of clopidogrel differs considerably among individuals and is thought to be closely related to the genetic polymorphism of CYP2C19. The CYP2C19*2 gene can reduce the antiplatelet aggregation effect of clopidogrel, which increases the risk of major cardiovascular adverse events in patients. In this research, we report a new type of biosensor for the highly sensitive detection of the CYP2C19*2 gene based on exonuclease III assisted electric signal amplification and the use of calixarene to enrich electrical signal substances. Specifically, under the best conditions, the logarithmic concentrations of the analytes have a good linear relationship with the peak current in the range of 0.01 fM to 100 pM and the detection limit is 13.49 aM. The results have also shown that this method has good selectivity, high sensitivity, and stability, etc., and will provide a very promising application for the detection of the CYP2C19*2 gene and other biological molecules by replacing corresponding nucleic acid sequences.