Andriy Volianiuk
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Andriy Volianiuk has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Tetiana Kropyvnytska
Lviv Polytechnic National University
3 shared publications - Andriy Kaminskyy
Lviv Polytechnic National University
2 shared publications - Orest Shyiko
Lviv Polytechnic National University
2 shared publications - Tetiana Kropyvnytska
Lviv Polytechnic National University
2 shared publications - Yurii Bobetskyi
Lviv Polytechnic National University
2 shared publications - Andrii Romaniuk1 shared publication
Latest Publications
- 20 November 2025
- Published by Lviv Polytechnic National University in Theory and Building Practice
- Vol. 2025 (2) , 83-88
DEVELOPMENT OF RAPID-HARDENING HIGH-STRENGTH FIBER-REINFORCED CONCRETE WITH INCREASED IMPACT RESISTANCE
The article describes the development of rapid-hardening, high-strength fiber-reinforced concrete with increased impact resistance for protective structures. Fiber-reinforced concretes with the addition of Portland cement CEM II/A-LL 42.5 R (C = 390 kg/m3) with polymer structural fiber PMS 1/60 with the addition of PCE were studied. The addition of PMS 1/60 fiber to concrete increases impact strength by 2.8-3.7 times and achieves a strength class of C 40/50. Fiber-reinforced concretes with the addition of Portland cement CEM II/A-S 52.5 R were studied. The addition of PMS 1/60 fiber provides an increase in the impact resistance of concrete at an early age by 2.7-3.1 times, and at the design age by 3.9-5.5 times. The developed fiber-reinforced concretes are classified as high-strength and rapid-hardening. The use of rapid-hardening high-strength fiber-reinforced concrete with increased impact resistance will increase resistance to mechanical loads and explosive impacts and ensure reliable protection of protective reinforced concrete structures.
- 20 November 2025
- Published by Lviv Polytechnic National University in Theory and Building Practice
- Vol. 2025 (2) , 83-88
DEVELOPMENT OF RAPID-HARDENING HIGH-STRENGTH FIBER-REINFORCED CONCRETE WITH INCREASED IMPACT RESISTANCE
The article describes the development of rapid-hardening, high-strength fiber-reinforced concrete with increased impact resistance for protective structures. Fiber-reinforced concretes with the addition of Portland cement CEM II/A-LL 42.5 R (C = 390 kg/m3) with polymer structural fiber PMS 1/60 with the addition of PCE were studied. The addition of PMS 1/60 fiber to concrete increases impact strength by 2.8-3.7 times and achieves a strength class of C 40/50. Fiber-reinforced concretes with the addition of Portland cement CEM II/A-S 52.5 R were studied. The addition of PMS 1/60 fiber provides an increase in the impact resistance of concrete at an early age by 2.7-3.1 times, and at the design age by 3.9-5.5 times. The developed fiber-reinforced concretes are classified as high-strength and rapid-hardening. The use of rapid-hardening high-strength fiber-reinforced concrete with increased impact resistance will increase resistance to mechanical loads and explosive impacts and ensure reliable protection of protective reinforced concrete structures.
- 30 October 2025
- Published by Springer Nature
- p. 169-178
Performance of Rapid Hardening Nanomodified Cement Mixtures for Repairing of Engineering Structures
- 30 October 2025
- Published by Springer Nature
- p. 169-178
Performance of Rapid Hardening Nanomodified Cement Mixtures for Repairing of Engineering Structures
- 9 August 2024
- Published by Springer Nature
- p. 341-349
Study of the Properties of Modified Concrete Containing Various Types of Fibers and Fly Ash
- 9 August 2024
- Published by Springer Nature
- p. 341-349
Study of the Properties of Modified Concrete Containing Various Types of Fibers and Fly Ash
- 20 June 2024
- Published by Lviv Polytechnic National University in Theory and Building Practice
- Vol. 2024 (1) , 92-99
RESISTANCE OF STRUCTURAL ELEMENTS OF CIVIL PROTECTION BUILDINGS AND STRUCTURES TO THE IMPACT OF AN EXPLOSION
The article presents the results of a comparison of the stability of the structural elements of the underground parking lot of an erected multistory civil building. The results of calculation of structural load-bearing elements (monolithic floor slab and pylons) to the impact of an explosion in the Lira CAD software with consideration of the requirements of the state Building standards of Ukraine are presented. It is shown that an increase in the instantaneous load of explosive pressure from 20 kPa (DBN B.2.2-5-97) to 100 kPa (DBN B.2.2-5:2023) will increase the maximum displacement of a monolithic floor slab by 11.9 times and the maximum reinforcement section by 5.8 times. This creates a real opportunity to develop new approaches to the planning of civil protection buildings and structures to ensure their operational reliability and resistance to the effects of an explosion.
- 20 June 2024
- Published by Lviv Polytechnic National University in Theory and Building Practice
- Vol. 2024 (1) , 92-99
RESISTANCE OF STRUCTURAL ELEMENTS OF CIVIL PROTECTION BUILDINGS AND STRUCTURES TO THE IMPACT OF AN EXPLOSION
The article presents the results of a comparison of the stability of the structural elements of the underground parking lot of an erected multistory civil building. The results of calculation of structural load-bearing elements (monolithic floor slab and pylons) to the impact of an explosion in the Lira CAD software with consideration of the requirements of the state Building standards of Ukraine are presented. It is shown that an increase in the instantaneous load of explosive pressure from 20 kPa (DBN B.2.2-5-97) to 100 kPa (DBN B.2.2-5:2023) will increase the maximum displacement of a monolithic floor slab by 11.9 times and the maximum reinforcement section by 5.8 times. This creates a real opportunity to develop new approaches to the planning of civil protection buildings and structures to ensure their operational reliability and resistance to the effects of an explosion.
- 20 June 2023
- Published by Lviv Polytechnic National University in Theory and Building Practice
- Vol. 2023 (1) , 37-42
HIGH STRENGTH STEEL FIBER REINFORCED CONCRETE FOR FORTIFICATION PROTECTED STRUCTURES
The article presents the results of research on modified steel fiber-reinforced concrete and shows the expediency of their use to increase the effectiveness of fortification protection structures against shock loads. It was established that according to the results of tests of compressive strength (fсm = 79.4 MPa) and tensile strength during bending (fс, lf = 7.4 MPa), steel fiber-reinforced concrete can be classified as high-strength (strength class C 50/60) and rapid-hardening (fcm2/ fcm28 = 0.57) in accordance with DSTU EN 206:2018. Manufacturing in factory conditions of reinforced concrete elements of structures based on high-strength steel fiber-reinforced concrete with increased resistance to various types of force effects during shelling will allow to obtain quick-assembling/quick-dismantling fortification structures that will be able to provide protection for the personnel of the units of the armed forces of Ukraine.
- 20 June 2023
- Published by Lviv Polytechnic National University in Theory and Building Practice
- Vol. 2023 (1) , 37-42
HIGH STRENGTH STEEL FIBER REINFORCED CONCRETE FOR FORTIFICATION PROTECTED STRUCTURES
The article presents the results of research on modified steel fiber-reinforced concrete and shows the expediency of their use to increase the effectiveness of fortification protection structures against shock loads. It was established that according to the results of tests of compressive strength (fсm = 79.4 MPa) and tensile strength during bending (fс, lf = 7.4 MPa), steel fiber-reinforced concrete can be classified as high-strength (strength class C 50/60) and rapid-hardening (fcm2/ fcm28 = 0.57) in accordance with DSTU EN 206:2018. Manufacturing in factory conditions of reinforced concrete elements of structures based on high-strength steel fiber-reinforced concrete with increased resistance to various types of force effects during shelling will allow to obtain quick-assembling/quick-dismantling fortification structures that will be able to provide protection for the personnel of the units of the armed forces of Ukraine.