CLChi Li

Chi Li

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Chi Li has a total of 4 co-authors. Here are the top co-authors by number of shared publications:

  • Changning Liu

    College of Physics and Electronic Science, Hubei Key Laboratory of Photoelectric Materials and Devices, Hubei Engineering Research Center for Micro-Nano Optoelectronic Devices and Integration, Hubei Normal University

    1 shared publication
  • Jie Ren

    College of Physics and Electronic Science, Hubei Normal University, Huangshi 435002, China

    1 shared publication
  • Lun Yang

    Hubei Key Laboratory of Photoelectric Materials and Devices, School of Materials Science and Engineering, Hubei Normal University, Huangshi 435002, China

    1 shared publication
  • Zhiqi Lu

    College of Physics and Electronic Science, Hubei Normal University, Huangshi 435002, China

    1 shared publication

Latest Publications

  • Open Access

    Ultra-High Sensitivity and Temperature-Insensitive Optical Fiber Strain Sensor Based on Dual Air Cavities

    by Zhiqi Lu, Changning Liu, Chi Li, Jie Ren, Lun Yang

    This study proposed an all-fiber Fabry–Perot interferometer (FPI) strain sensor with two miniature bubble cavities. The device was fabricated by writing two axial, mutually close short-line structures via femtosecond laser pulse illumination to induce a refractive index modified area in the core of a single-mode fiber (SMF). Subsequently, the gap between the two short lines was discharged with a fusion splicer, resulting in the formation of two adjacent bubbles simultaneously in a standard SMF. When measured directly, the strain sensitivity of dual air cavities is 2.4 pm/με, the same as that of a single bubble. The measurement range for a single bubble is 802.14 µε, while the measurement range for a double bubble is 1734.15 µε. Analysis of the envelope shows that the device possesses a strain sensitivity of up to 32.3 pm/με, which is 13.5 times higher than that of a single air cavity. Moreover, with a maximum temperature sensitivity of only 0.91 pm/°C, the temperature cross sensitivity could be neglected. As the device is based on the internal structure inside the optical fiber, its robustness could be guarantee. The device is simple to prepare, highly sensitive, and has wide application prospects in the field of strain measurement.