Carlos Colino-Paniagua
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Carlos Colino-Paniagua has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Alfonso Alvarado-Lorenzo
Department of Surgery, Faculty of Medicine, University of Salamanca, 37008 Salamanca, Spain
3 shared publications - Pedro Colino-Gallardo
Department of Dentistry, Universidad Católica San Antonio de Murcia, 30107 Murcia, Spain
3 shared publications - Alberto Albaladejo Martínez
Department of Surgery, Faculty of Medicine, University of Salamanca, 37008 Salamanca, Spain
1 shared publication - Aldara Rosalía Nercellas Rodríguez
Department of Surgery, Faculty of Medicine, University of Salamanca, 37008 Salamanca, Spain
1 shared publication - Elena Calzadilla-Suárez
Department of Surgery, Faculty of Medicine, University of Salamanca, Salamanca, Spain
1 shared publication - Giuseppe Scuzzo
Department of Orthodontics, Università Cattolica del Sacro Cuore, Rome, Italy
1 shared publication
Latest Publications
- Open Access
- 18 August 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (16) , 9074
Comparison of the Predictability of Dentoalveolar Expansion with Different Aligner Systems in Orthodontics: A Longitudinal Clinical Study in Adult Patients
Aligners represent a therapeutic option in orthodontics, offering advantages such as aesthetics, comfort, and individualized prescriptions for each patient. However, the predictability of maxillary expansion is subject to variability. The objective of this article is to evaluate the efficacy and predictability of aligners in maxillary expansion. One hundred adult patients were included in this study, divided into four groups, each assigned to a different brand of clear aligners: Angel Aligners, Invisalign, Spark, or HeySmile. Digital models were obtained at three stages: initial STL (T1), prediction (T2), and final (T3) (before the first refinement). The models were measured to obtain linear distances between canines, first bicuspids, second bicuspids, and first molars. Statistical analysis was performed using SPSS 28.0. The best predictability was obtained in the lower arch (68.900%) for second bicuspids, while the worst accuracy was for canines (39.290% in the upper arch using Invisalign). Angel aligner showed the highest percentage of predictability (60.002%) among the evaluated brands, followed by HeySmile (59.895%), Spark (59.275%), and Invisalign (57.153%). The results show that clear aligners are an effective treatment for transverse movements in both arches. However, further research is needed to improve predictability.
- 18 August 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (16) , 9074
Open AccessComparison of the Predictability of Dentoalveolar Expansion with Different Aligner Systems in Orthodontics: A Longitudinal Clinical Study in Adult Patients
Aligners represent a therapeutic option in orthodontics, offering advantages such as aesthetics, comfort, and individualized prescriptions for each patient. However, the predictability of maxillary expansion is subject to variability. The objective of this article is to evaluate the efficacy and predictability of aligners in maxillary expansion. One hundred adult patients were included in this study, divided into four groups, each assigned to a different brand of clear aligners: Angel Aligners, Invisalign, Spark, or HeySmile. Digital models were obtained at three stages: initial STL (T1), prediction (T2), and final (T3) (before the first refinement). The models were measured to obtain linear distances between canines, first bicuspids, second bicuspids, and first molars. Statistical analysis was performed using SPSS 28.0. The best predictability was obtained in the lower arch (68.900%) for second bicuspids, while the worst accuracy was for canines (39.290% in the upper arch using Invisalign). Angel aligner showed the highest percentage of predictability (60.002%) among the evaluated brands, followed by HeySmile (59.895%), Spark (59.275%), and Invisalign (57.153%). The results show that clear aligners are an effective treatment for transverse movements in both arches. However, further research is needed to improve predictability.
- Open Access
- 13 December 2023
- Published by MDPI AG in Biomedicines
- Vol. 11 (12) , 3305
Skeletal and Dentoalveolar Changes in Growing Patients Treated with Rapid Maxillary Expansion Measured in 3D Cone-Beam Computed Tomography
The skeletal and dental effects of rapid maxillary expansion (RME) have been extensively studied, but high-quality research is still needed to determine the three-dimensional (3D) effects of RME. The aim of this study was to compare skeletal and dentoalveolar parameters through cone-beam computed tomography (CBCT) pre- (T1) and post-treatment (T2) with respect to RME. Twenty growing patients (mean age 10.7 years) were treated with a Hyrax-type expander. A 3D CBCT was performed at T1 and T2, measuring nasal width, maxillary width, palatal height, maxillary arch perimeter, angulation of the upper first molar, and intermolar width. The mean palatal suture opening was 2.85 ± 0.62 mm (p < 0.0001). Nasal width increased 1.28 ± 0.64 mm and maxillary width 2.79 ± 1.48 mm (p < 0.0001). In contrast, palatal height was reduced 0.65 ± 0.64 mm (p < 0.0001). Regarding arch perimeter, the radicular perimeter increased 2.89 ± 1.80 mm, while the coronal perimeter increased 3.42 ± 2.09 mm (p < 0.0001). Molar angulation increased 5.62 ± 3.20° for the right molar and 4.74 ± 2.22° for the left molar (p < 0.0001). Intermolar width increased 5.21 ± 1.55 mm (p < 0.0001). Treatment with Hyrax produced a significant opening in the mean palatal suture. Also, a significant increase in nasal width, maxillary width, arch perimeter, molar angulation, and intermolar width, and a decrease in palatal height, were observed.
- 13 December 2023
- Published by MDPI AG in Biomedicines
- Vol. 11 (12) , 3305
Open AccessSkeletal and Dentoalveolar Changes in Growing Patients Treated with Rapid Maxillary Expansion Measured in 3D Cone-Beam Computed Tomography
The skeletal and dental effects of rapid maxillary expansion (RME) have been extensively studied, but high-quality research is still needed to determine the three-dimensional (3D) effects of RME. The aim of this study was to compare skeletal and dentoalveolar parameters through cone-beam computed tomography (CBCT) pre- (T1) and post-treatment (T2) with respect to RME. Twenty growing patients (mean age 10.7 years) were treated with a Hyrax-type expander. A 3D CBCT was performed at T1 and T2, measuring nasal width, maxillary width, palatal height, maxillary arch perimeter, angulation of the upper first molar, and intermolar width. The mean palatal suture opening was 2.85 ± 0.62 mm (p < 0.0001). Nasal width increased 1.28 ± 0.64 mm and maxillary width 2.79 ± 1.48 mm (p < 0.0001). In contrast, palatal height was reduced 0.65 ± 0.64 mm (p < 0.0001). Regarding arch perimeter, the radicular perimeter increased 2.89 ± 1.80 mm, while the coronal perimeter increased 3.42 ± 2.09 mm (p < 0.0001). Molar angulation increased 5.62 ± 3.20° for the right molar and 4.74 ± 2.22° for the left molar (p < 0.0001). Intermolar width increased 5.21 ± 1.55 mm (p < 0.0001). Treatment with Hyrax produced a significant opening in the mean palatal suture. Also, a significant increase in nasal width, maxillary width, arch perimeter, molar angulation, and intermolar width, and a decrease in palatal height, were observed.
- Open Access
- 20 May 2023
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 13 (5) , 859
A New Digital Method to Quantify the Effects Produced by Carriere Motion Appliance
The aim of this study was to analyze a novel digital technique to quantify the distal tooth displacement and derotation angle produced by the Carriere Motion Appliance (CMA). Twenty-one patients with a class II molar and canine relationship underwent orthodontic treatment with CMA. All patients were exposed before (STL1) and after the CMA placement (STL2), submitted to a digital impression, and afterwards, data were uploaded to specific cephalometric software to allow automatic mesh network alignment of the STL digital files. Subsequently, the distal tooth displacement of the upper canines and first upper molars, as well as the derotation angle of the first upper molars were analyzed using the Pearson correlation coefficient (ρ). Repeatability and reproducibility were analyzed using Gage R&R statistical analysis. An increase in canine displacement was correlated with an increase in contralateral canine displacement (ρ = 0.759; p < 0.000). An increase in canine displacement was correlated with an increase in molar displacement (ρ = 0.715; p < 0.001). An increase in upper first molar displacement was correlated with an increase in the contralateral upper first molar displacement (ρ = 0.609; p < 0.003) and the canine displacement (ρ = 0.728; p < 0.001). The distal tooth displacement showed a repeatability of 0.62% and reproducibility of 7.49%, and the derotation angle showed a repeatability of 0.30% and reproducibility of 0.12%. The novel digital measurement technique is a reproducible, repeatable, and accurate method for quantifying the distal tooth displacement of the upper canine and first upper molar, as well as the derotation angle of the first upper molars after using CMA.
- 20 May 2023
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 13 (5) , 859
Open AccessA New Digital Method to Quantify the Effects Produced by Carriere Motion Appliance
The aim of this study was to analyze a novel digital technique to quantify the distal tooth displacement and derotation angle produced by the Carriere Motion Appliance (CMA). Twenty-one patients with a class II molar and canine relationship underwent orthodontic treatment with CMA. All patients were exposed before (STL1) and after the CMA placement (STL2), submitted to a digital impression, and afterwards, data were uploaded to specific cephalometric software to allow automatic mesh network alignment of the STL digital files. Subsequently, the distal tooth displacement of the upper canines and first upper molars, as well as the derotation angle of the first upper molars were analyzed using the Pearson correlation coefficient (ρ). Repeatability and reproducibility were analyzed using Gage R&R statistical analysis. An increase in canine displacement was correlated with an increase in contralateral canine displacement (ρ = 0.759; p < 0.000). An increase in canine displacement was correlated with an increase in molar displacement (ρ = 0.715; p < 0.001). An increase in upper first molar displacement was correlated with an increase in the contralateral upper first molar displacement (ρ = 0.609; p < 0.003) and the canine displacement (ρ = 0.728; p < 0.001). The distal tooth displacement showed a repeatability of 0.62% and reproducibility of 7.49%, and the derotation angle showed a repeatability of 0.30% and reproducibility of 0.12%. The novel digital measurement technique is a reproducible, repeatable, and accurate method for quantifying the distal tooth displacement of the upper canine and first upper molar, as well as the derotation angle of the first upper molars after using CMA.