SLSoo Jee Lee

Soo Jee Lee

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Soo Jee Lee has a total of 7 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • The Effects of Distance and Warming Temperature on Intensity of Extremely Low Frequency Electromagnetic Field from Forced-Air Warming System

    by Soo Jee Lee, Yong Han Kim

    Purpose. Electronic devices, increasingly used in operating rooms, heavily depend on mains electricity. This may significantly increase occupational exposure to extremely low frequency electromagnetic field. As a possible carcinogen as per International Agency for Research on Cancer, Swedish Confederation of Professional Employee recommended it should be below 2 mG. Forced air warming system is used to prevent hypothermia. This study was to investigate the effect of distance and warming temperature on extremely low frequency electromagnetic field intensity from Bair-Hugger™ Warming Unit, in order to find the minimum safe distance from the device. Materials and methods. The forced-air warming unit was hung on the side of an operating table in an empty operating room, with all other electronic devices turned off. With three different warming temperatures, electromagnetic field was measured at 15, 30, and 45 cm from the anterior surface of the device. Data was collected at a sampling time of 0.5 times per second for 10 minutes. Kruskal-Wallis one-way analysis was used. Results. Increasing warming temperature and reducing the distance from the device resulted in a significant increase in electromagnetic field intensity (p <0.05). At 45 cm in particular, low and medium warming temperatures showed significantly lower intensity compared to high temperature (p<0.05). Exposure below 2.0 mG was achieved only when it was at 45 cm regardless of temperature. Conclusions. Health workers should be aware of occupational exposure to extremely low frequency electromagnetic field and avoid as much as possible. It is suggested to stay at least 45 cm away from 3M Bair Hugger™ Warming Unit.

  • Open Access

    Case report of atypical re-sedation after general anesthesia using remimazolam

    by Soo Jee Lee, Insik Jung, Seongmin Park, Seunghee Ki

    Background: Remimazolam, an ultra-short-acting anesthetic with flumazenil as a reversal agent, typically facilitates patient awakening postoperative. However, our case reveals an unusual occurrence: despite flumazenil initially restoring consciousness, re-sedation due to remimazolam ensued six hours later.Case: A 65-year-old woman underwent total intravenous general anesthesia with remimazolam and remifentanil during the 140-min surgery. Despite an initially smooth recovery, she progressively became drowsy upon transfer to the general ward, eventually reaching a stuporous state. Multiple interventions, including opioid reversal (intravenous patient-controlled analgesia discontinuation and naloxone administration), were attempted. Neurological consultation revealed no issues; however, immediate improvement after flumazenil administration suggested remimazolam's involvement. The patient was discharged without complications.Conclusions: This case challenges our understanding of remimazolam's dynamics, emphasizing the necessity for vigilant post-anesthesia monitoring, even in seemingly low-risk cases. It advocates for standardized response protocols to promptly manage unforeseen events and ensure patient safety.


  • Open Access

    Perioperative cutaneous complications in an elderly patient due to inappropriate use of a forced-air warming device and underbody blanket: a case report

    by Myounghun Kim, Soo Jee Lee, Beomseok Choi, Geunho Lee, Seunghee Ki

    Forced-air warming is commonly utilized to prevent perioperative hypothermia. Underbody warming blankets are often employed to secure a larger area for patient warming. While forced-air warming systems are generally regarded as safe, improper usage poses a risk of cutaneous complications. Additionally, the influence of underbody blankets on cutaneous complications remains uncertain. We present a case of cutaneous complications resulting from the improper utilization of a forced-air warming device and an underbody blanket. A 79-year-old man presented to the hospital for robotic proctectomy under general anesthesia. The surgery lasted for 7 hours, and the forced-air warming device with underbody blanket operated continuously for 5 hours intraoperatively. The surgery was completed without any incidents. However, first-degree burns on the patient’s back, along with superficial decubitus ulcers on his right scapula, were observed after surgery. To prevent cutaneous complications, clinicians must adhere to the manufacturer's guidelines when utilizing a forced-air warming system. Compared to overbody blankets, underbody blankets have limitations in monitoring cutaneous responses. Ensuring patient safety requires selecting an appropriate blanket for scheduled operations.