SYShintaro Yamagami

Shintaro Yamagami

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Shintaro Yamagami has a total of 145 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Pulmonary Vein Reconnection Burden and Extra‐Pulmonary Vein Ablation During Second Catheter Ablation for Atrial Fibrillation in the Pre‐Pulsed‐Field Ablation Era: A Multicenter Registry

    by Yoshimori An, Tetsuma Kawaji, Shushi Nishiwaki, Yasuhiro Sasaki, Junichi Ooka, Kazuto Kujira, Tomoyuki Inoue, Misaki Naka, Akihira Suenaga, Hiroto Tanaka, et al.

    Background: Contemporary procedural characteristics of second catheter ablation (CA) for atrial fibrillation (AF) remain incompletely characterized. Objective: To investigate procedural characteristics and clinical implications of pulmonary vein (PV) reconnection during second CA for AF. Methods: We analyzed 854 patients who underwent second CA for AF between April 2021 and March 2024 at nine institutions before the clinical adoption of pulsed‐field ablation. Patients were stratified according to the number of reconnected PVs identified during the procedures: none (0), single (1), and multiple (≥ 2). The primary endpoint was freedom from atrial arrhythmia recurrence, assessed using multivariable Cox proportional hazards models. Results: During second CA, PV reconnections (21% per vein) were identified and re‐isolated in all affected PVs. Patients with no PV reconnection accounted for 55.5% ( n = 474) of the cohort and underwent extra‐PV ablation more frequently than those with single ( n = 146) or multiple ( n = 234) reconnected PVs. During a median follow‐up of 706 days, multiple reconnected PVs with subsequent re‐isolation were associated with a lower risk of atrial arrhythmia recurrence than no PV reconnection. This association remained significant after multivariable adjustment (hazard ratio 0.69, 95% confidence interval 0.50–0.95; p = 0.023) and was more pronounced in patients without symptomatic heart failure ( p for interaction = 0.009). Enlarged left atrial diameter, non‐paroxysmal AF, and symptomatic heart failure were also independently associated with recurrence, whereas additional extra‐PV ablation was not. Conclusion: Re‐isolation of multiple reconnected PVs was independently associated with a lower risk of atrial arrhythmia recurrence after second CA for AF, particularly in patients without symptomatic heart failure.

  • Stopping Oral Anticoagulation After Catheter Ablation for Atrial Fibrillation in Patients With High Risk of Stroke: STOP‐OAC Study

    by Tetsuma Kawaji, Yoshimori An, Shushi Nishiwaki, Yasuhiro Sasaki, Junichi Ooka, Kazuto Kujira, Akifumi Morinaga, Misaki Naka, Akihira Suenaga, Hiroto Tanaka, et al.

    Background: The benefit of continuing oral anticoagulation (OAC) after catheter ablation (CA) for atrial fibrillation (AF) in patients with a high risk of stroke remains unclear. The Safeness or Threat Of Pausing‐Oral anticoagulant therapy After Catheter ablation for atrial fibrillation study (STOP‐OAC study) aimed to investigate the safety and efficacy of OAC discontinuation after CA for AF in patients with CHADS 2 score ≥2. Methods: We enrolled 1655 consecutive patients with AF with CHADS 2 score ≥2 (mean CHADS 2 of 2.4 and CHA 2 DS 2 ‐VASc of 3.8) who underwent first‐time CA at 8 institutions in Japan from April 2021 to March 2024. The main analysis was the landmark analysis at 240 days after CA compared between the 2 groups either on or off OAC at 240 days. Results: There were 327 patients who had stopped OAC at 240 days (off‐OAC group), and 1241 patients who continued OAC at 240 days (on‐OAC group). Patients in the off‐OAC group compared with those in the on‐OAC group less often had nonparoxysmal AF (43.1% and 54.3%), and history of ischemic stroke (7.7% and 23.4%) with lower CHADS 2 score (2.2±0.5 and 2.4±0.6). The incidence of ischemic stroke beyond 240 days was not different between the 2 groups (0.4% and 0.5% per patient‐year, P =0.21), whereas the incidence of major or clinically relevant nonmajor bleeding beyond 240 days was significantly lower in the off‐OAC group than in the on‐OAC group (0.4% and 1.7% per patient‐year, P 2 score ≥2.


  • Impact of application repetition on Joule heating and lesion formation using a circular-shaped pulsed field catheter

    by Mizuki Okumura, Shintaro Yamagami, Masaya Akiyama, Yuta Nakano, Yu Amano, Toyoki Okuda, Tsukasa Motoyoshi, Ryuki Chatani, Hirokazu Kondo, Toshihiro Tamura

    Introduction Pulsed field ablation (PFA) is a non-thermal ablation modality, but repeated high-voltage applications can still cause Joule heating at the electrode–tissue interface. We evaluated the effects of application repetition and inter-application intervals on temperature rise and lesion depth using a circular-shaped PFA catheter. Methods and Results In an in vitro potato model, a circular-shaped PFA catheter was tested under five settings: 1×, 2×, 2× with a 10-s interval, 4×, and 4× with a 10-s interval. Maximum electrode surface temperature was measured using a thermal camera, and lesion depth was assessed by TTC staining (n = 5 per setting). Temperature increased significantly with application repetition and was attenuated by a 10-s interval (overall P < 0.0001). Lesion depth also increased with repetition (overall P < 0.0001), but did not differ significantly between interval and no-interval conditions at equal application numbers. Conclusion In this simplified in vitro model, a short inter-application interval was associated with attenuation of temperature rise during repeated PFA delivery, while lesion depth was not significantly reduced.

  • Open Access

    Reduced Left Atrial Appendage Flow Velocity as a Risk of Thromboembolic Events After Catheter Ablation of Atrial Fibrillation

    by Shintaro Yamagami, Satoshi Shizuta, Munekazu Tanaka, Shushi Nishiwaki, Takanori Aizawa, Akihiro Komasa, Takashi Yoshizawa, Tetsuma Kawaji, Chihiro Ota, Naoaki Onishi, et al.

    Background: Reduced left atrial appendage flow velocity (LAAFV) on transesophageal echocardiography (TEE) is recognized as a predictor of thromboembolic events (TEs) in patients with atrial fibrillation (AF). However, its long‐term prognostic value following AF ablation remains unclear. Methods and Results: We retrospectively evaluated 1521 patients undergoing AF ablation who underwent preprocedural TEE. Patients were categorized into two groups based on LAAFV: reduced (≤ 21.4 cm/s, n = 99) and preserved (> 21.4 cm/s, n = 1422). The primary outcome was TEs. Secondary outcomes included arrhythmia recurrence and major adverse cardiovascular events (MACEs), defined as a composite of all‐cause death, stroke, major bleeding, and heart failure hospitalization, as well as individual components and cardiovascular mortality. Over a mean follow‐up of 49 ± 32 months, TEs occurred in 19 patients (1.2%). The 5‐year cumulative incidence of TEs was significantly higher in the reduced LAAFV group (6.7% vs. 0.9%, p < 0.0001), despite a lower rate of anticoagulation discontinuation (20.1% vs. 57.1%, p < 0.0001). Multivariable analysis identified reduced LAAFV as an independent predictor of TEs. It was also associated with higher risks for all secondary endpoints. Conclusions: Reduced preprocedural LAAFV is associated with adverse long‐term clinical outcomes after AF ablation, including a significantly increased risk of thromboembolic events.


  • Open Access

    A case of marked atrial sensing delay after a pacemaker implantation after mitral valve surgery via the superior transseptal approach

    by Tsukasa Motoyoshi, Shintaro Yamagami, Tomohiro Sato, Toyoki Okuda, Hirokazu Kondo, Toshihiro Tamura

  • Open Access

    Near-zero fluoroscopy pulsed field ablation using the circular-shaped catheter with ICE-guided real-time fifth electrode visualization: The FOCUS technique

    by Shintaro Yamagami, Toyoki Okuda, Tsukasa Motoyoshi, Masanori Murayama, Masaya Akiyama, Yuta Nakano, Hirokazu Kondo, Toshihiro Tamura

  • Open Access

    A case of groin lymphorrhea after a leadless pacemaker implantation

    by Tsukasa Motoyoshi, Shintaro Yamagami, Tomohiro Sato, Toyoki Okuda, Hirokazu Kondo, Toshihiro Tamura

  • Open Access

    Fluoroless coronary sinus cannulation using a BeeAT catheter and the CARTO mapping system

    by Shintaro Yamagami, Tsukasa Motoyoshi, Takashi Kanda, Toshihiro Tamura


  • Cryoballoon vs radiofrequency ablation in persistent atrial fibrillation: the CRRF-PeAF trial

    by Koji Miyamoto, Koshiro Kanaoka, Kenji Yodogawa, Yuhi Fujimoto, Hiroshi Fukunaga, So Asano, Takahiko Nagase, Muryo Terasawa, Takahiro Kusume, Yasuyuki Takada, et al.

    Background and Aims: There are limited prospective data on the efficacy, safety, and impact on reverse remodelling of cryoballoon ablation as compared to radiofrequency ablation for persistent atrial fibrillation. Methods: A prospective, multicentre, randomized, non-inferiority clinical trial was conducted to compare the efficacy and safety of cryoballoon vs radiofrequency ablation for persistent atrial fibrillation. A total of 500 patients with persistent atrial fibrillation were randomized across 12 centres. The primary endpoint was the occurrence of atrial tachyarrhythmias at 1 year with a 90-day blanking period after ablation. Results: The final analysis included 499 patients, with a median age of 69 years (interquartile range, 61–74); 249 patients were allocated to the cryoballoon group, and 250 to the radiofrequency group. In the intention-to-treat analysis, the primary endpoint was observed in 56 patients (22.5%) in the cryoballoon group and 58 (23.2%) in the radiofrequency group, and the cryoballoon group demonstrated non-inferiority compared to the radiofrequency group for the primary endpoint (hazard ratio .99; 95% confidence interval, .69–1.43; P = .96). The radiofrequency group showed a greater reduction in left atrial size (left atrial volume index) at 1 year than the cryoballoon group [−11 mL/m2 (interquartile range, −19 to −4) vs −4 mL/m2 (interquartile range, −13 to 3), P < .001]. Conclusions: In this randomized trial, cryoballoon ablation was non-inferior to radiofrequency ablation for the occurrence of atrial tachyarrhythmias at 1 year in patients with persistent atrial fibrillation.


  • Open Access

    SCN5A variant type-dependent risk prediction in Brugada syndrome

    by Takanori Aizawa, Takeru Makiyama, Hai Huang, Tomohiko Imamura, Megumi Fukuyama, Keiko Sonoda, Koichi Kato, Takashi Hisamatsu, Yuko Nakamura, Kenji Hoshino, et al.

    Aims: The variant in SCN5A with the loss of function (LOF) effect in the cardiac Na+ channel (Nav1.5) is the definitive cause for Brugada syndrome (BrS), and the functional analysis data revealed that LOF variants are associated with poor prognosis. However, which variant types (e.g. missense or non-missense) affect the prognoses of those variant carriers remain unelucidated. Methods and results: We defined SCN5A LOF variants as all non-missense and missense variants that produce peak INa < 65% of wild-type previously confirmed by patch-clamp studies. The study population consisted of 76 Japanese BrS patients (74% patients were male and the median age [IQR] at diagnosis was 28 [14–45] years) with LOF type of SCN5A variants: 40 with missense and 36 with non-missense variants. Non-missense variant carriers presented significantly more severe cardiac conduction disorder compared to the missense variant carriers. During follow-up periods of 9.0 [5.0–14.0] years, compared to missense variants, non-missense variants were significant risk factors of lifetime lethal arrhythmia events (LAEs) (P = 0.023). When focusing only on the missense variants that produce no peak INa, these missense variant carriers exhibited the same clinical outcomes as those with non-missense (log-rank P = 0.325). After diagnosis, however, both variant types were comparable in risk of LAEs (P = 0.155). Conclusion: We identified, for the first time, that SCN5A non-missense variants were associated with higher probability of LAE than missense variants in BrS patients though it did not change significantly after diagnosis.