Kostadinka Bizheva
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Kostadinka Bizheva has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
Prabakar Puvanathasan
Department of Physics and Astronomy, University of Waterloo, Waterloo, Ontario, Canada
2 shared publicationsShelley Boyd
St. Michaels Hospital, Department of Ophthalmology and Vision Science, and University of Toronto, Toronto, Ontario M5B 1W8 Canada
2 shared publicationsAkshaya Mishra
Dept. of Systems Design Engineering, University of Waterloo, Waterloo, ON N2L3G1, Canada
1 shared publication- Alexander Wong
Department of System Design Engineering, University of Waterloo, Waterloo, ON N2L 3G1, Canada
1 shared publication Alireza Akhlagh Moayed
University of Waterloo, Department of Physics and Astronomy, 200 University Avenue West, Waterloo, Ontario N2L3G1 Canada
1 shared publicationBruce Doran
Diagnosys LLC, Suite 500, 175 Cabot Street Lowell, Massachusetts 01854
1 shared publication
Latest Publications
- Open Access
- 1 July 2010
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 15 (04) , 040508-040508-3
In vivo volumetric imaging of the human upper eyelid with ultrahigh-resolution optical coherence tomography
The upper eyelid is a biological tissue with complex structure, essential for the maintenance of an optically clear ocular surface due to its physical (blinking) effect. The Meibomian glands (MGs) are structures that lie beneath the surface of the inner eyelid and are partially responsible for the production of the superficial oily layer of the tear film. The MGs are only superficially visible under magnification when the eyelid is everted. We present for the first time in vivo 3-D images of healthy and inflamed human MGs. Tomograms were acquired from the tarsal plate of everted human eyelids with a ultrahigh-resolution optical coherence tomography (UHOCT) system, with resolution in biological tissue at the rate of 91,911 A-scans/s. Comparison with histology shows that the UHOCT images reveal a spatial distribution of structures that appear to correspond with the MGs’ acini and ducts (in healthy subjects), and accumulation of heterogeneous, highly scattering biological material and clear fluids in the visibly blocked glands. Noninvasive, volumetric high-resolution morphological imaging of the human tarsal area could have a significant impact in the clinical diagnosis of inflammatory and noninflammatory lid pathologies.- 1 July 2010
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 15 (04) , 040508-040508-3
Open AccessIn vivo volumetric imaging of the human upper eyelid with ultrahigh-resolution optical coherence tomography
The upper eyelid is a biological tissue with complex structure, essential for the maintenance of an optically clear ocular surface due to its physical (blinking) effect. The Meibomian glands (MGs) are structures that lie beneath the surface of the inner eyelid and are partially responsible for the production of the superficial oily layer of the tear film. The MGs are only superficially visible under magnification when the eyelid is everted. We present for the first time in vivo 3-D images of healthy and inflamed human MGs. Tomograms were acquired from the tarsal plate of everted human eyelids with a ultrahigh-resolution optical coherence tomography (UHOCT) system, with resolution in biological tissue at the rate of 91,911 A-scans/s. Comparison with histology shows that the UHOCT images reveal a spatial distribution of structures that appear to correspond with the MGs’ acini and ducts (in healthy subjects), and accumulation of heterogeneous, highly scattering biological material and clear fluids in the visibly blocked glands. Noninvasive, volumetric high-resolution morphological imaging of the human tarsal area could have a significant impact in the clinical diagnosis of inflammatory and noninflammatory lid pathologies. - Open Access
- 1 January 2010
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 15 (4) , 040506-040506-3
Combined optical coherence tomography and electroretinography system for in vivo simultaneous morphological and functional imaging of the rodent retina
A combined ultrahigh resolution optical coherence tomography (UHROCT) and a electroretinography (ERG) system is presented for simultaneous imaging of the retinal structure and physiological response to light stimulation in the rodent eye. The UHROCT system provides resolution in the rat retina and time resolution of . A custom-designed light stimulator integrated into the UHROCT imaging probe provides light stimuli with user-selected color, duration, and intensity. The performance of the combined system is demonstrated in vivo in healthy rats, and in a rat model of drug-induced outer retinal degeneration. Experimental results show correlation between the observed structural and physiological changes in the healthy and degenerated retina.- 1 January 2010
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 15 (4) , 040506-040506-3
Open AccessCombined optical coherence tomography and electroretinography system for in vivo simultaneous morphological and functional imaging of the rodent retina
A combined ultrahigh resolution optical coherence tomography (UHROCT) and a electroretinography (ERG) system is presented for simultaneous imaging of the retinal structure and physiological response to light stimulation in the rodent eye. The UHROCT system provides resolution in the rat retina and time resolution of . A custom-designed light stimulator integrated into the UHROCT imaging probe provides light stimuli with user-selected color, duration, and intensity. The performance of the combined system is demonstrated in vivo in healthy rats, and in a rat model of drug-induced outer retinal degeneration. Experimental results show correlation between the observed structural and physiological changes in the healthy and degenerated retina. - 11 December 2009
- Published by Optica Publishing Group in Optics Express
- Vol. 17 (26) , 23719-23728
Intra-retinal layer segmentation in optical coherence tomography images
Retinal layer thickness, evaluated as a function of spatial position from optical coherence tomography (OCT) images is an important diagnostics marker for many retinal diseases. However, due to factors such as speckle noise, low image contrast, irregularly shaped morphological features such as retinal detachments, macular holes, and drusen, accurate segmentation of individual retinal layers is difficult. To address this issue, a computer method for retinal layer segmentation from OCT images is presented. An efficient two-step kernel-based optimization scheme is employed to first identify the approximate locations of the individual layers, which are then refined to obtain accurate segmentation results for the individual layers. The performance of the algorithm was tested on a set of retinal images acquired in-vivo from healthy and diseased rodent models with a high speed, high resolution OCT system. Experimental results show that the proposed approach provides accurate segmentation for OCT images affected by speckle noise, even in sub-optimal conditions of low image contrast and presence of irregularly shaped structural features in the OCT images.
- 11 December 2009
- Published by Optica Publishing Group in Optics Express
- Vol. 17 (26) , 23719-23728
Intra-retinal layer segmentation in optical coherence tomography images
Retinal layer thickness, evaluated as a function of spatial position from optical coherence tomography (OCT) images is an important diagnostics marker for many retinal diseases. However, due to factors such as speckle noise, low image contrast, irregularly shaped morphological features such as retinal detachments, macular holes, and drusen, accurate segmentation of individual retinal layers is difficult. To address this issue, a computer method for retinal layer segmentation from OCT images is presented. An efficient two-step kernel-based optimization scheme is employed to first identify the approximate locations of the individual layers, which are then refined to obtain accurate segmentation results for the individual layers. The performance of the algorithm was tested on a set of retinal images acquired in-vivo from healthy and diseased rodent models with a high speed, high resolution OCT system. Experimental results show that the proposed approach provides accurate segmentation for OCT images affected by speckle noise, even in sub-optimal conditions of low image contrast and presence of irregularly shaped structural features in the OCT images.
- 23 October 2008
- Published by Optica Publishing Group in Optics Letters
- Vol. 33 (21) , 2479-2481
High-speed, high-resolution Fourier-domain optical coherence tomography system for retinal imaging in the 1060 nm wavelength region
A high-speed , ultrahigh axial resolution Fourier domain optical coherence tomography (OCT) system for retinal imaging at , based on a linear array, readout rate InGaAs camera is presented. When interfaced with a custom superluminescent diode (, , ), the system provides axial OCT resolution at the surface of biological tissue, in vivo in rat retina, in vivo in human retina, and sensitivity for incident power and integration time. Retinal tomograms acquired in vivo from a human volunteer and a rat animal model show clear visualization of all intraretinal layer and increased penetration into the choroid.- 23 October 2008
- Published by Optica Publishing Group in Optics Letters
- Vol. 33 (21) , 2479-2481
High-speed, high-resolution Fourier-domain optical coherence tomography system for retinal imaging in the 1060 nm wavelength region
A high-speed , ultrahigh axial resolution Fourier domain optical coherence tomography (OCT) system for retinal imaging at , based on a linear array, readout rate InGaAs camera is presented. When interfaced with a custom superluminescent diode (, , ), the system provides axial OCT resolution at the surface of biological tissue, in vivo in rat retina, in vivo in human retina, and sensitivity for incident power and integration time. Retinal tomograms acquired in vivo from a human volunteer and a rat animal model show clear visualization of all intraretinal layer and increased penetration into the choroid.- 1 January 2007
- Published by Optica Publishing Group in Optics Express
- Vol. 15 (24) , 15747-15758
Speckle noise reduction algorithm for optical coherence tomography based on interval type II fuzzy set
A novel speckle reduction technique based on soft thresholding of wavelet coefficients using interval type II fuzzy system was developed for reducing speckle noise in Optical Coherence Tomography images. The proposed algorithm is an extension of a recently published method for filtering additive Gaussian noise by use of type I fuzzy system. Unlike type I, interval type II fuzzy based thresholding filter considers the uncertainty in the calculated threshold and the wavelet coefficient is adjusted based on this uncertainty. A single parameter controls the signal-to-noise (SNR) improvement. Application of this novel algorithm to optical coherence tomograms acquired in-vivo from a human finger tip show reduction in the speckle noise with little edge blurring and image SNR improvement of about 10dB. Comparison with adaptive Wiener and adaptive Lee filters, applied to the same image, demonstrated the superior performance of the fuzzy type II algorithm in terms of image metrics improvement.
- 1 January 2007
- Published by Optica Publishing Group in Optics Express
- Vol. 15 (24) , 15747-15758
Speckle noise reduction algorithm for optical coherence tomography based on interval type II fuzzy set
A novel speckle reduction technique based on soft thresholding of wavelet coefficients using interval type II fuzzy system was developed for reducing speckle noise in Optical Coherence Tomography images. The proposed algorithm is an extension of a recently published method for filtering additive Gaussian noise by use of type I fuzzy system. Unlike type I, interval type II fuzzy based thresholding filter considers the uncertainty in the calculated threshold and the wavelet coefficient is adjusted based on this uncertainty. A single parameter controls the signal-to-noise (SNR) improvement. Application of this novel algorithm to optical coherence tomograms acquired in-vivo from a human finger tip show reduction in the speckle noise with little edge blurring and image SNR improvement of about 10dB. Comparison with adaptive Wiener and adaptive Lee filters, applied to the same image, demonstrated the superior performance of the fuzzy type II algorithm in terms of image metrics improvement.