Do Jin Im
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Do Jin Im has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
In Seok Kang
Department of Chemical Engineering, Pohang University of Science and Technology, San 31 Hyoja-dong, Nam-Gu, Pohang, Gyeongbuk, 790-784, South Korea
6 shared publicationsDustin Moon
Department of Chemical Engineering, Pohang University of Science and Technology, San31 Hyoja-dong, Nam-Gu, Pohang, Gyeongbuk, 790-784, South Korea
3 shared publicationsMyung Mo Ahn
Department of Chemical Engineering, Pohang University of Science and Technology, San 31 Hyoja-dong, Nam-Gu, Pohang, Gyeongbuk, South Korea 790-784.
3 shared publicationsByeong Sun Yoo
Department of Chemical Engineering, Pohang University of Science and Technology, San31 Hyoja-dong, Nam-Gu, Pohang, Gyeongbuk, 790-784, South Korea
2 shared publicationsJihoon Noh
Pohang University of Science and Technology (POSTECH) 1 Department of Chemical Engineering San 31, Hyoja-Dong, Nam-Gu, Pohang, Gyeongbuk 790-784, South Korea
2 shared publicationsDong Sung Kim
Department of Mechanical Engineering, Pohang University of Science and Technology, San 31 Hyoja-dong, Nam-Gu, Pohang, Gyeongbuk, 790-784, South Korea
1 shared publication
Latest Publications
- Open Access
- 8 October 2013
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 138 (24) , 7362-7368
Geometric characterization of optimal electrode designs for improved droplet charging and actuation
Droplet charging characteristics depending on the geometry of charging electrodes have been investigated experimentally and numerically. In the experiments, two contrasting electrode systems are examined: pin–pin versus planar–planar types. To confirm the different charging behaviours on each electrode, an asymmetric system of a pin–planar type has also been examined. From the experimental and numerical results, it has been found that the droplet charge can be significantly increased (more than four times) with pin type electrodes compared with planar ones due to the increase in surface charge density by the intensification of the electric field around the charging electrode. Moreover, as the system scale becomes smaller, the superior charging effect becomes greater. Through comprehensive numerical studies on the effects of the cross-sectional area and length of a charging electrode, we have found the optimal geometric design of an electrode for droplet charging and actuation. The implications for basic understanding of the charging phenomenon and electrode design of microfluidic systems are discussed.
- 8 October 2013
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 138 (24) , 7362-7368
Open AccessGeometric characterization of optimal electrode designs for improved droplet charging and actuation
Droplet charging characteristics depending on the geometry of charging electrodes have been investigated experimentally and numerically. In the experiments, two contrasting electrode systems are examined: pin–pin versus planar–planar types. To confirm the different charging behaviours on each electrode, an asymmetric system of a pin–planar type has also been examined. From the experimental and numerical results, it has been found that the droplet charge can be significantly increased (more than four times) with pin type electrodes compared with planar ones due to the increase in surface charge density by the intensification of the electric field around the charging electrode. Moreover, as the system scale becomes smaller, the superior charging effect becomes greater. Through comprehensive numerical studies on the effects of the cross-sectional area and length of a charging electrode, we have found the optimal geometric design of an electrode for droplet charging and actuation. The implications for basic understanding of the charging phenomenon and electrode design of microfluidic systems are discussed.
- Open Access
- 20 June 2013
- Published by Springer Nature in Scientific Reports
- Vol. 3 (1) , srep02037
Spontaneous electrical charging of droplets by conventional pipetting
We report that a droplet dispensed from a micropipette almost always has a considerable electrical charge of a magnitude dependent on the constituents of the droplet, on atmospheric humidity and on the coating material of pipette tip. We show that this natural electrification of a droplet originates from the charge separation between a droplet and pipette tip surface by contact with water due to the ionization of surface chemical groups. Charge on a droplet can make it difficult to detach the droplet from the pipette tip, can decrease its surface tension, can affect the chemical characteristics of solutions due to interactions with charged molecules, and can influence the combination and localization of charged bio-molecules; in all cases, the charge may affect results of experiments in which any of these factors is important. Thus, these findings reveal experimental parameters that should be controlled in experiments that use micropipettes.
- 20 June 2013
- Published by Springer Nature in Scientific Reports
- Vol. 3 (1) , srep02037
Open AccessSpontaneous electrical charging of droplets by conventional pipetting
We report that a droplet dispensed from a micropipette almost always has a considerable electrical charge of a magnitude dependent on the constituents of the droplet, on atmospheric humidity and on the coating material of pipette tip. We show that this natural electrification of a droplet originates from the charge separation between a droplet and pipette tip surface by contact with water due to the ionization of surface chemical groups. Charge on a droplet can make it difficult to detach the droplet from the pipette tip, can decrease its surface tension, can affect the chemical characteristics of solutions due to interactions with charged molecules, and can influence the combination and localization of charged bio-molecules; in all cases, the charge may affect results of experiments in which any of these factors is important. Thus, these findings reveal experimental parameters that should be controlled in experiments that use micropipettes.
- 14 March 2013
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 85 (8) , 4038-4044
Digital Electrophoresis of Charged Droplets
A digital microfluidic system based on a direct electric charging and subsequent electrophoretic manipulation of droplets is made by simple fabrication at low cost. Digitally controlled two-dimensional droplet motions are realized by digital polarity control of an array of electrodes. By independent control of droplets and colorimetric detection, the coalescence and mixing of droplets is analyzed quantitatively. The gelation of sodium alginate and the crystallization of calcium carbonate by multiple droplet translations and coalescence and the actuation of glassy carbon beads are demonstrated to show the versatile manipulation capability of the proposed technology. Finally, we discuss the implications and potentials of the present technology.
- 14 March 2013
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 85 (8) , 4038-4044
Digital Electrophoresis of Charged Droplets
A digital microfluidic system based on a direct electric charging and subsequent electrophoretic manipulation of droplets is made by simple fabrication at low cost. Digitally controlled two-dimensional droplet motions are realized by digital polarity control of an array of electrodes. By independent control of droplets and colorimetric detection, the coalescence and mixing of droplets is analyzed quantitatively. The gelation of sodium alginate and the crystallization of calcium carbonate by multiple droplet translations and coalescence and the actuation of glassy carbon beads are demonstrated to show the versatile manipulation capability of the proposed technology. Finally, we discuss the implications and potentials of the present technology.
- 27 September 2012
- Published by Elsevier in Computers & Fluids
- Vol. 70, 13-20
Numerical analysis on the enhancement of molten steel stirring by magnetic field strength control
- 27 September 2012
- Published by Elsevier in Computers & Fluids
- Vol. 70, 13-20
Numerical analysis on the enhancement of molten steel stirring by magnetic field strength control
- 1 August 2012
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 28 (32) , 11656-11661
Discrete Electrostatic Charge Transfer by the Electrophoresis of a Charged Droplet in a Dielectric Liquid
We have experimentally investigated the electrostatic charging of a water droplet on an electrified electrode surface to explain the detailed inductive charging processes and use them for the detection of droplet position in a lab-on-a-chip system. The periodic bouncing motion of a droplet between two planar electrodes has been examined by using a high-resolution electrometer and an image analysis method. We have found that this charging process consists of three steps. The first step is inductive charge accumulation on the opposite electrode by the charge of a droplet. This induction process occurs while the droplet approaches the electrode, and it produces an induction current signal at the electrometer. The second step is the discharging of the droplet by the accumulated induced charge at the moment of contact. For this second step, there is no charge-transfer detection at the electrometer. The third step is the charging of the neutralized droplet to a certain charged state while the droplet is in contact with the electrode. The charge transfer of the third step is detected as the pulse-type signal of an electrometer. The second and third steps occur simultaneously and rapidly. We have found that the induction current by the movement of a charged droplet can be accurately used to measure the charge of the droplet and can also be used to monitor the position of a droplet under actuation. The implications of the current findings for understanding and measuring the charging process are discussed.
- 1 August 2012
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 28 (32) , 11656-11661
Discrete Electrostatic Charge Transfer by the Electrophoresis of a Charged Droplet in a Dielectric Liquid
We have experimentally investigated the electrostatic charging of a water droplet on an electrified electrode surface to explain the detailed inductive charging processes and use them for the detection of droplet position in a lab-on-a-chip system. The periodic bouncing motion of a droplet between two planar electrodes has been examined by using a high-resolution electrometer and an image analysis method. We have found that this charging process consists of three steps. The first step is inductive charge accumulation on the opposite electrode by the charge of a droplet. This induction process occurs while the droplet approaches the electrode, and it produces an induction current signal at the electrometer. The second step is the discharging of the droplet by the accumulated induced charge at the moment of contact. For this second step, there is no charge-transfer detection at the electrometer. The third step is the charging of the neutralized droplet to a certain charged state while the droplet is in contact with the electrode. The charge transfer of the third step is detected as the pulse-type signal of an electrometer. The second and third steps occur simultaneously and rapidly. We have found that the induction current by the movement of a charged droplet can be accurately used to measure the charge of the droplet and can also be used to monitor the position of a droplet under actuation. The implications of the current findings for understanding and measuring the charging process are discussed.
- 1 December 2011
- Published by AIP Publishing in Biomicrofluidics
- Vol. 5 (4) , 044112-4411210
Influences of electric field on living cells in a charged water-in-oil droplet under electrophoretic actuation
We experimentally investigate the effects of high electric field on living cells inside a charged droplet under electrophoretic actuation. When an aqueous droplet suspended in a dielectric liquid contacts with electrified electrode, the droplet acquires charge. This charged droplet undergoes electrophoretic motion under strong electric field (1–3 kV/cm), which can be used as a droplet manipulation method in biomicrofluidic applications. However, because strong electric field and use of dielectric oil can be a harmful environment for living cells, the biological feasibilities have been tested. Trypan blue test and cell growth test have been performed to check the viability and proliferation of cells in a droplet under various electric field strengths and actuation times. We have not observed any noticeable influence of electric field and silicone oil on the viability and proliferation of cells, which indicates that electrophoresis could be safely used as a manipulation method for a droplet containing living biological system.
- 1 December 2011
- Published by AIP Publishing in Biomicrofluidics
- Vol. 5 (4) , 044112-4411210
Influences of electric field on living cells in a charged water-in-oil droplet under electrophoretic actuation
We experimentally investigate the effects of high electric field on living cells inside a charged droplet under electrophoretic actuation. When an aqueous droplet suspended in a dielectric liquid contacts with electrified electrode, the droplet acquires charge. This charged droplet undergoes electrophoretic motion under strong electric field (1–3 kV/cm), which can be used as a droplet manipulation method in biomicrofluidic applications. However, because strong electric field and use of dielectric oil can be a harmful environment for living cells, the biological feasibilities have been tested. Trypan blue test and cell growth test have been performed to check the viability and proliferation of cells in a droplet under various electric field strengths and actuation times. We have not observed any noticeable influence of electric field and silicone oil on the viability and proliferation of cells, which indicates that electrophoresis could be safely used as a manipulation method for a droplet containing living biological system.
- 31 May 2011
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 83 (13) , 5168-5174
Electrophoresis of a Charged Droplet in a Dielectric Liquid for Droplet Actuation
Electrophoretic motion of a charged droplet in a dielectric fluid under an electric field has been investigated experimentally for use as a microdroplet actuation method. The effects of the droplet size, electric field strength, and electrolyte concentration and ion species on the charging of an aqueous droplet have been examined. The amount of electrical charging has been measured by two different methods: indirect measurement using the image analysis of droplet motion and direct measurement using the electrometer. Quantitative comparison of the droplet charge measured experimentally and the theoretical value of a perfectly conductive sphere shows that an aqueous droplet is less charged than the corresponding perfectly conductive sphere. The limiting effect on electrical charging is more significant for an electrolyte droplet, and the effect is positively correlated to the electrolyte concentration rather than the ion species. This implies that the low electrical conductivity of water is not a major cause of the limiting effect. The scaling law of the charging amount for a deionized water droplet nearly follows that of the perfect conductor, whereas for an electrolyte droplet, the scaling law exponent is slightly higher. Some advantages and potentials of the current droplet actuation method are also discussed in comparison with the conventional ones.
- 31 May 2011
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 83 (13) , 5168-5174
Electrophoresis of a Charged Droplet in a Dielectric Liquid for Droplet Actuation
Electrophoretic motion of a charged droplet in a dielectric fluid under an electric field has been investigated experimentally for use as a microdroplet actuation method. The effects of the droplet size, electric field strength, and electrolyte concentration and ion species on the charging of an aqueous droplet have been examined. The amount of electrical charging has been measured by two different methods: indirect measurement using the image analysis of droplet motion and direct measurement using the electrometer. Quantitative comparison of the droplet charge measured experimentally and the theoretical value of a perfectly conductive sphere shows that an aqueous droplet is less charged than the corresponding perfectly conductive sphere. The limiting effect on electrical charging is more significant for an electrolyte droplet, and the effect is positively correlated to the electrolyte concentration rather than the ion species. This implies that the low electrical conductivity of water is not a major cause of the limiting effect. The scaling law of the charging amount for a deionized water droplet nearly follows that of the perfect conductor, whereas for an electrolyte droplet, the scaling law exponent is slightly higher. Some advantages and potentials of the current droplet actuation method are also discussed in comparison with the conventional ones.