Scott T. Lovald
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Scott T. Lovald has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
Andrew Rau
Exponent, San Francisco, CA
3 shared publicationsBeverly Diamond
Philadelphia, Pennsylvania
2 shared publicationsDeana Mercer
Philadelphia, Pennsylvania
2 shared publicationsIan Cowgill
Philadelphia, Pennsylvania
2 shared publicationsJean Hanson
Philadelphia, Pennsylvania
2 shared publicationsJeff Gonzales
University of Colorado School of Medicine, Aurora, Colorado
2 shared publications
Latest Publications
- 23 August 2024
- Published by Parenteral Drug Association, Inc. in PDA Journal of Pharmaceutical Science and Technology
- Vol. 78 (4) , 518-519
Finite Element Analysis of Skin Deformation and Puncture for Microneedle Array Design
The mechanics of microneedle insertion have thus far been studied in a limited manner. Previous work has focused on buckling and failure of microneedle devices, while providing little insight into skin deformation, puncture, and the final positioning of needle tips under full microneedle arrays. The current study aims to develop a numerical approach capable of evaluating deformation and puncture conditions for full microneedle array designs. The analysis included a series of finite element submodels used to calibrate the microneedle-epidermal interface for failure properties using traction-separation laws. The single needle model is validated using experimental data and imaging, including results from a customized nanoindentation procedure to measure loads and displacements during microneedle insertion. Upon validation, full microneedle arrays are implemented in a 3 D finite element model and a design framework is developed, allowing evaluation of different design variables (i.e. needle shape, material, spacing) with respect to outputs relevant to successful microneedle performance. Results from the model include skin deformation, force to puncture, penetration depth, and the punctured state at each microneedle tip. In addition to microneedle parameters, patient parameters such as subcutaneous tissue thickness are included to evaluate the sensitivity of different microneedle designs to expected patient and anatomical region variability.
- 23 August 2024
- Published by Parenteral Drug Association, Inc. in PDA Journal of Pharmaceutical Science and Technology
- Vol. 78 (4) , 518-519
Finite Element Analysis of Skin Deformation and Puncture for Microneedle Array Design
The mechanics of microneedle insertion have thus far been studied in a limited manner. Previous work has focused on buckling and failure of microneedle devices, while providing little insight into skin deformation, puncture, and the final positioning of needle tips under full microneedle arrays. The current study aims to develop a numerical approach capable of evaluating deformation and puncture conditions for full microneedle array designs. The analysis included a series of finite element submodels used to calibrate the microneedle-epidermal interface for failure properties using traction-separation laws. The single needle model is validated using experimental data and imaging, including results from a customized nanoindentation procedure to measure loads and displacements during microneedle insertion. Upon validation, full microneedle arrays are implemented in a 3 D finite element model and a design framework is developed, allowing evaluation of different design variables (i.e. needle shape, material, spacing) with respect to outputs relevant to successful microneedle performance. Results from the model include skin deformation, force to puncture, penetration depth, and the punctured state at each microneedle tip. In addition to microneedle parameters, patient parameters such as subcutaneous tissue thickness are included to evaluate the sensitivity of different microneedle designs to expected patient and anatomical region variability.
- 23 August 2024
- Published by Parenteral Drug Association, Inc. in PDA Journal of Pharmaceutical Science and Technology
- Vol. 78 (4) , 516-517
Nonlinear Tissue Permeability Drives Tissue Pressure and Injection Distribution: A Computational Investigation of Subcutaneous Injections
There is a significant opportunity to expand the understanding of subcutaneous injection mechanics with an aim to increase injectable volume while controlling tissue strain and associated subject pain. Computational modeling can evaluate the mechanics of subcutaneous injections as a supplement to experimental, animal and clinical studies. The objectives of this study are to (1) develop a computational model for subcutaneous injection in tissue, (2) investigate the influence anisotropic tissue permeability has on bolus formation, and (3) explore the effects that injection flow rate and viscosity have on injection flow and tissue strain. Poroelastic models with subsurface flow were implemented in finite element software (COMSOL, ABAQUS). Pore pressure and injectate distribution showed excellent agreement with experimental results when evaluated at multiple injection rates (20 ml/hr, 120 ml/hr and 360 ml/hr). Including the anisotropy of tissue permeability causes the injectate to preferentially spread horizontally, similar to experimentally observed bolus distributions. Cases are presented to provide additional insight into injection mechanics, including variations on the delivery rate, the injection volume, viscosity and the thickness of the subcutaneous layer. The results support the use of computational modeling as a valid tool for understanding tissue strains and injectate distributions for large volume injections.
- 23 August 2024
- Published by Parenteral Drug Association, Inc. in PDA Journal of Pharmaceutical Science and Technology
- Vol. 78 (4) , 516-517
Nonlinear Tissue Permeability Drives Tissue Pressure and Injection Distribution: A Computational Investigation of Subcutaneous Injections
There is a significant opportunity to expand the understanding of subcutaneous injection mechanics with an aim to increase injectable volume while controlling tissue strain and associated subject pain. Computational modeling can evaluate the mechanics of subcutaneous injections as a supplement to experimental, animal and clinical studies. The objectives of this study are to (1) develop a computational model for subcutaneous injection in tissue, (2) investigate the influence anisotropic tissue permeability has on bolus formation, and (3) explore the effects that injection flow rate and viscosity have on injection flow and tissue strain. Poroelastic models with subsurface flow were implemented in finite element software (COMSOL, ABAQUS). Pore pressure and injectate distribution showed excellent agreement with experimental results when evaluated at multiple injection rates (20 ml/hr, 120 ml/hr and 360 ml/hr). Including the anisotropy of tissue permeability causes the injectate to preferentially spread horizontally, similar to experimentally observed bolus distributions. Cases are presented to provide additional insight into injection mechanics, including variations on the delivery rate, the injection volume, viscosity and the thickness of the subcutaneous layer. The results support the use of computational modeling as a valid tool for understanding tissue strains and injectate distributions for large volume injections.
- 20 June 2023
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 144, 105986
Developing failure criteria for laceration injury of dermal tissue
- 20 June 2023
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 144, 105986
Developing failure criteria for laceration injury of dermal tissue
- 8 August 2018
- Vol. 27 (2) , 148-154
Risk of Opioid-Related Adverse Events After Primary and Revision Total Knee Arthroplasty.
Postoperative analgesia after primary total knee arthroplasty (TKA) and revision knee arthroplasty (RKA) can be reliant on the use of opioids and may lead to opioid-related adverse events (ORAEs). This study evaluated the risk of ORAEs following TKA and RKA using the 5% Medicare claims (2010-2013) database. There were 41,702 TKA and 3817 RKA patients who met the inclusion criteria. At 90 days, respiratory complications were the most common complication (TKA: 6.12%; RKA: 8.01%), followed by postoperative nausea and vomiting (TKA: 2.86%; RKA: 3.95%), and urinary retention complications (TKA: 2.79%; RKA: 3.20%). For TKA, risk factors for respiratory complications included older age, lower socioeconomic status, more comorbidities, obesity, chronic obstructive pulmonary disease, white race, and patients in the Midwest and West (vs. South) (p 002). The average Medicare payment for treating complications within 90 days of a TKA was $6206 and $6222 following RKA. Awareness risks for ORAEs in select patients can assist in developing a multimodal postoperative pain control and patient education protocols. (Journal of Surgical Orthopaedic Advances 27(2):148-154, 2018).
- 8 August 2018
- Vol. 27 (2) , 148-154
Risk of Opioid-Related Adverse Events After Primary and Revision Total Knee Arthroplasty.
Postoperative analgesia after primary total knee arthroplasty (TKA) and revision knee arthroplasty (RKA) can be reliant on the use of opioids and may lead to opioid-related adverse events (ORAEs). This study evaluated the risk of ORAEs following TKA and RKA using the 5% Medicare claims (2010-2013) database. There were 41,702 TKA and 3817 RKA patients who met the inclusion criteria. At 90 days, respiratory complications were the most common complication (TKA: 6.12%; RKA: 8.01%), followed by postoperative nausea and vomiting (TKA: 2.86%; RKA: 3.95%), and urinary retention complications (TKA: 2.79%; RKA: 3.20%). For TKA, risk factors for respiratory complications included older age, lower socioeconomic status, more comorbidities, obesity, chronic obstructive pulmonary disease, white race, and patients in the Midwest and West (vs. South) (p 002). The average Medicare payment for treating complications within 90 days of a TKA was $6206 and $6222 following RKA. Awareness risks for ORAEs in select patients can assist in developing a multimodal postoperative pain control and patient education protocols. (Journal of Surgical Orthopaedic Advances 27(2):148-154, 2018).
- 1 February 2017
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 66, 104-110
Finite element analysis and experimental evaluation of penetrating injury through the cornea
- 1 February 2017
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 66, 104-110
Finite element analysis and experimental evaluation of penetrating injury through the cornea
- 1 January 2017
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 475 (1) , 94-105
No Difference in Early Analgesia Between Liposomal Bupivacaine Injection and Intrathecal Morphine After TKA
Opioid analgesics have been a standard modality for postoperative pain management after total knee arthroplasty (TKA) but are also associated with increased risk of nausea, pruritus, vomiting, respiratory depression, prolonged ileus, and cognitive dysfunction. There is still a need for a method of anesthesia that can deliver effective long-term postoperative pain relief without incurring the high cost and health burden of opioids and nerve blocks. (1) Is liposomal bupivacaine-based periarticular injection (PAI) more effective than morphine-based spinal anesthesia or ropivacaine-based PAI in controlling postoperative pain after TKA? (2) Do patients treated with liposomal bupivacaine-based PAI experience fewer opioid-related adverse events compared with patients treated with morphine-based spinal anesthesia or ropivacaine-based PAI in controlling postoperative pain after TKA? This multicenter, blind trial randomized 119 patients undergoing TKA with spinal anesthesia to receive spinal anesthesia plus periarticular injection with liposomal bupivacaine (40 patients), spinal anesthesia with bupivacaine plus intrathecal morphine (41 patients) but no liposomal bupivacaine injection, or spinal anesthesia with bupivacaine (38 patients) and no liposomal bupivacaine injection. The two groups that did not receive periarticular liposomal bupivacaine did receive periarticular injection with ropivacaine, and all three groups had ketorolac (30 mg) plus epinephrine (1:1000) in the periarticular injections. Patients in all three groups received identical perioperative multimodal analgesic and antiemetic drugs. All patients were analyzed in the group to which they were randomized and no patients were lost to followup. The primary study endpoints were visual analog score (VAS) for pain and narcotic use during postoperative day 1. Secondary endpoints included side effects associated with narcotic administration during the hospital stay. Mean VAS pain in the liposomal bupivacaine PAI group was lower than that for the ropivacaine PAI group at 6 hours (1.8 ± 2.1 versus 3.3 ± 2.3, p = 0.005, mean difference: 1.5, 95% confidence interval [CI], 0.5–2.5) and 12 hours (1.5 ± 2.0 versus 3.3 ± 2.4, p < 0.001, mean difference: 1.8, 95% CI, 0.8–2.8) after surgery. The morphine spinal group had lower pain compared with the liposomal bupivacaine PAI group at 6 hours (0.9 ± 1.8 versus 1.8 ± 2.1, p = 0.035, mean difference: 1.0, 95% CI, 0.1–1.8), but there was no difference at 12 hours (0.8 ± 1.5 versus 1.5 ± 2.0, p = 0.086, mean difference: 0.7, 95% CI, −0.1 to 1.5). The magnitude of the differences at 6 and 12 hours are near the lower end of minimal clinically important differences reported in the literature, and thus the improvement shown in this study may only represent a small clinical improvement. Both the liposomal bupivacaine group (13% [five of 40]) and the ropivacaine group (5% [two of 38]) had fewer incidents of itching (pruritus) than the spinal morphine group (38% [15 of 41]) (p = 0.001). This prospective multicenter three-arm blind randomized controlled trial showed potentially improved pain control at 6 and 12 hours in the liposomal bupivacaine and intrathecal morphine groups compared with the ropivacaine group at the cost of much higher incidences of pruritus (itching) in the intrathecal morphine group. Based on these results, we prefer the use of PAI with liposomal bupivacaine as an alternative to spinal anesthesia with intrathecal morphine as a result of similar postoperative pain control and the potential for reducing adverse events. Level I, therapeutic study.
- 1 January 2017
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 475 (1) , 94-105
No Difference in Early Analgesia Between Liposomal Bupivacaine Injection and Intrathecal Morphine After TKA
Opioid analgesics have been a standard modality for postoperative pain management after total knee arthroplasty (TKA) but are also associated with increased risk of nausea, pruritus, vomiting, respiratory depression, prolonged ileus, and cognitive dysfunction. There is still a need for a method of anesthesia that can deliver effective long-term postoperative pain relief without incurring the high cost and health burden of opioids and nerve blocks. (1) Is liposomal bupivacaine-based periarticular injection (PAI) more effective than morphine-based spinal anesthesia or ropivacaine-based PAI in controlling postoperative pain after TKA? (2) Do patients treated with liposomal bupivacaine-based PAI experience fewer opioid-related adverse events compared with patients treated with morphine-based spinal anesthesia or ropivacaine-based PAI in controlling postoperative pain after TKA? This multicenter, blind trial randomized 119 patients undergoing TKA with spinal anesthesia to receive spinal anesthesia plus periarticular injection with liposomal bupivacaine (40 patients), spinal anesthesia with bupivacaine plus intrathecal morphine (41 patients) but no liposomal bupivacaine injection, or spinal anesthesia with bupivacaine (38 patients) and no liposomal bupivacaine injection. The two groups that did not receive periarticular liposomal bupivacaine did receive periarticular injection with ropivacaine, and all three groups had ketorolac (30 mg) plus epinephrine (1:1000) in the periarticular injections. Patients in all three groups received identical perioperative multimodal analgesic and antiemetic drugs. All patients were analyzed in the group to which they were randomized and no patients were lost to followup. The primary study endpoints were visual analog score (VAS) for pain and narcotic use during postoperative day 1. Secondary endpoints included side effects associated with narcotic administration during the hospital stay. Mean VAS pain in the liposomal bupivacaine PAI group was lower than that for the ropivacaine PAI group at 6 hours (1.8 ± 2.1 versus 3.3 ± 2.3, p = 0.005, mean difference: 1.5, 95% confidence interval [CI], 0.5–2.5) and 12 hours (1.5 ± 2.0 versus 3.3 ± 2.4, p < 0.001, mean difference: 1.8, 95% CI, 0.8–2.8) after surgery. The morphine spinal group had lower pain compared with the liposomal bupivacaine PAI group at 6 hours (0.9 ± 1.8 versus 1.8 ± 2.1, p = 0.035, mean difference: 1.0, 95% CI, 0.1–1.8), but there was no difference at 12 hours (0.8 ± 1.5 versus 1.5 ± 2.0, p = 0.086, mean difference: 0.7, 95% CI, −0.1 to 1.5). The magnitude of the differences at 6 and 12 hours are near the lower end of minimal clinically important differences reported in the literature, and thus the improvement shown in this study may only represent a small clinical improvement. Both the liposomal bupivacaine group (13% [five of 40]) and the ropivacaine group (5% [two of 38]) had fewer incidents of itching (pruritus) than the spinal morphine group (38% [15 of 41]) (p = 0.001). This prospective multicenter three-arm blind randomized controlled trial showed potentially improved pain control at 6 and 12 hours in the liposomal bupivacaine and intrathecal morphine groups compared with the ropivacaine group at the cost of much higher incidences of pruritus (itching) in the intrathecal morphine group. Based on these results, we prefer the use of PAI with liposomal bupivacaine as an alternative to spinal anesthesia with intrathecal morphine as a result of similar postoperative pain control and the potential for reducing adverse events. Level I, therapeutic study.
- 1 January 2016
- Published by Data Trace Publishing Company in Journal of Surgical Orthopaedic Advances
- Vol. 26 (1)
2016
- 1 January 2016
- Published by Data Trace Publishing Company in Journal of Surgical Orthopaedic Advances
- Vol. 26 (1)
2016
- 1 October 2015
- Published by Elsevier in Orthopedic Clinics of North America
- Vol. 46 (4) , 469-477
Liposomal Bupivacaine
- 1 October 2015
- Published by Elsevier in Orthopedic Clinics of North America
- Vol. 46 (4) , 469-477
Liposomal Bupivacaine
- 30 September 2013
- Published by Wiley in Otolaryngology–Head and Neck Surgery
- Vol. 149 (6) , 858-864
Biomechanics of the Monopedicle Skin Flap
Objective: The design and implementation of skin flaps remains a puzzle for the reconstructive surgeon. The objective of the present study is to use finite element (FE) analysis to characterize and understand the biomechanics of the monopedicle skin flap design.Study Design: The current study uses a nonlinear hyperelastic FE model of the human skin to understand the biomechanics of monopedicle‐based flap designs as geometric flap parameters are varied.Setting: In silico.Subjects and Methods: The simulation included the displacement loading, stitching, and relaxation of various forms of the flap design. Stress and strain outcomes, previously correlated with scarring, necrosis, and blood perfusion, are reported for a basic monopedicle design as well as a number of modifications to this design.Results: The results suggest that the length of the monopedicle flap should not exceed 3 times the size of the defect, as the benefit in reducing principal strain (deformation) is diminished beyond this point. Further, to minimize skin strain, the ideal Burrow's triangle size can be described as proportional to flap length and inversely proportional to defect height, according to a linear function.Conclusion: The ideal flap design should attempt to minimize not only the stress in the skin, but the size of the incisions and the degree of undermining. The results of our analyses provide guidance to increase the general understanding of monopedicle flap mechanics and provide context for the clinician and insight into designing a better monopedicle flap for individual situations.
- 30 September 2013
- Published by Wiley in Otolaryngology–Head and Neck Surgery
- Vol. 149 (6) , 858-864
Biomechanics of the Monopedicle Skin Flap
Objective: The design and implementation of skin flaps remains a puzzle for the reconstructive surgeon. The objective of the present study is to use finite element (FE) analysis to characterize and understand the biomechanics of the monopedicle skin flap design.Study Design: The current study uses a nonlinear hyperelastic FE model of the human skin to understand the biomechanics of monopedicle‐based flap designs as geometric flap parameters are varied.Setting: In silico.Subjects and Methods: The simulation included the displacement loading, stitching, and relaxation of various forms of the flap design. Stress and strain outcomes, previously correlated with scarring, necrosis, and blood perfusion, are reported for a basic monopedicle design as well as a number of modifications to this design.Results: The results suggest that the length of the monopedicle flap should not exceed 3 times the size of the defect, as the benefit in reducing principal strain (deformation) is diminished beyond this point. Further, to minimize skin strain, the ideal Burrow's triangle size can be described as proportional to flap length and inversely proportional to defect height, according to a linear function.Conclusion: The ideal flap design should attempt to minimize not only the stress in the skin, but the size of the incisions and the degree of undermining. The results of our analyses provide guidance to increase the general understanding of monopedicle flap mechanics and provide context for the clinician and insight into designing a better monopedicle flap for individual situations.
- 1 January 2012
- Published by Wolters Kluwer Health
- Vol. 72 (1) , 282-287
Hardware removal after fracture fixation procedures in the femur
Background: The purpose of this study was to conduct an examination of internal fixation of femoral fractures in a large national database. The study aims were to determine the percentage of fixation procedures that result in hardware removal in a single year and to assess differences in the likelihood for hardware removal procedures using patient characteristics. Methods: The 2007 Nationwide Inpatient Sample was used to quantify all patients who received an open reduction and internal fixation procedure for a fracture of the femur and all patients with a removal of implanted devices from the femur. The differences in patient characteristics between both groups were assessed using statistical methods. Results: Internal fixation of the femur was reported in 30,943 patients. Hardware removals were reported in 4,886 patients. The removal rate for the year was estimated to be 15.8%. Treatment failure was most often because of mechanical complications (18.7%), osteoarthritis (14.3%), nonunion (13.9%), refracture (10.9%), and other implant-oriented complications (10.1%). Males and younger patients composed a significantly higher percentage of removal procedures than fixation procedures (p < 0.0001 for both). Removal rates were lower in Self-Pay and Medicare patients, while the opposite was true for Medicaid and private insurance/HMO patients (p < 0.0001). Conclusion: The results of this study suggest that gender, age, and insurance status may influence the likelihood of an implant removal procedure. Given that removal was more likely in males and younger patients, and most often because of mechanical and implant-oriented complications, patient activity and weight bearing are likely leading factors in implant removal.
- 1 January 2012
- Published by Wolters Kluwer Health
- Vol. 72 (1) , 282-287
Hardware removal after fracture fixation procedures in the femur
Background: The purpose of this study was to conduct an examination of internal fixation of femoral fractures in a large national database. The study aims were to determine the percentage of fixation procedures that result in hardware removal in a single year and to assess differences in the likelihood for hardware removal procedures using patient characteristics. Methods: The 2007 Nationwide Inpatient Sample was used to quantify all patients who received an open reduction and internal fixation procedure for a fracture of the femur and all patients with a removal of implanted devices from the femur. The differences in patient characteristics between both groups were assessed using statistical methods. Results: Internal fixation of the femur was reported in 30,943 patients. Hardware removals were reported in 4,886 patients. The removal rate for the year was estimated to be 15.8%. Treatment failure was most often because of mechanical complications (18.7%), osteoarthritis (14.3%), nonunion (13.9%), refracture (10.9%), and other implant-oriented complications (10.1%). Males and younger patients composed a significantly higher percentage of removal procedures than fixation procedures (p < 0.0001 for both). Removal rates were lower in Self-Pay and Medicare patients, while the opposite was true for Medicaid and private insurance/HMO patients (p < 0.0001). Conclusion: The results of this study suggest that gender, age, and insurance status may influence the likelihood of an implant removal procedure. Given that removal was more likely in males and younger patients, and most often because of mechanical and implant-oriented complications, patient activity and weight bearing are likely leading factors in implant removal.