Cheol Song
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Cheol Song has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
Dae-Gab Gweon
Nano-opto Mechatronics Lab, Department of Mechanical Engineering , KAIST , Daejeon, Korea
1 shared publicationDaeGab Gweon
Nano-Opto-Mechatronics Lab., Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon, Republic of Korea
1 shared publicationMyoungKi Ahn
Nano-Opto-Mechatronics Lab., Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon, Republic of Korea
1 shared publicationTae Joong Kim
Nano-opto Mechatronics Lab, Department of Mechanical Engineering , KAIST , Daejeon, Korea
1 shared publication
Latest Publications
- 27 October 2010
- Published by Optica Publishing Group in Optics Express
- Vol. 18 (23) , 23805-23817
Polarization-sensitive spectral-domain optical coherence tomography using a multi-line single camera spectrometer
We describe a polarization sensitive spectral domain optical coherence tomography technique based on a single camera spectrometer that includes a multiplexed custom grating, camera lenses, and a high-speed three-line CCD camera. Two orthogonally polarized beams could be separately taken by two lines of the camera as a result of vertically different incident angles. The system could provide the imaging capabilities of a full camera speed and increased measurable depth. The proposed optical coherence tomography system could make a distinction between the normal muscle and cancerous tissue from the chest of a DSred GFP mouse and the OCT images were compared with those of in vivo confocal microscopy.
- 27 October 2010
- Published by Optica Publishing Group in Optics Express
- Vol. 18 (23) , 23805-23817
Polarization-sensitive spectral-domain optical coherence tomography using a multi-line single camera spectrometer
We describe a polarization sensitive spectral domain optical coherence tomography technique based on a single camera spectrometer that includes a multiplexed custom grating, camera lenses, and a high-speed three-line CCD camera. Two orthogonally polarized beams could be separately taken by two lines of the camera as a result of vertically different incident angles. The system could provide the imaging capabilities of a full camera speed and increased measurable depth. The proposed optical coherence tomography system could make a distinction between the normal muscle and cancerous tissue from the chest of a DSred GFP mouse and the OCT images were compared with those of in vivo confocal microscopy.
- Open Access
- 30 March 2007
- Published by Taylor & Francis in International Journal of Optomechatronics
- Vol. 1 (1) , 27-45
Beam Scanning Confocal Differential Heterodyne Interferometry
This article presents a new approach to the design of confocal differential heterodyne interferometer (CDHI), which is a combination of differential heterodyne interferometer (DHI) with confocal laser scanning microscopy (CLSM). The CDHI can measure a step height over a quarter of wavelength of the light source, which can not be accurately measured by DHI and CLSM, respectively. The approach is that it utilizes a beam-scanning method instead of transporting a sample to be measured. The measurement results carried out for samples having step height are found to be comparable in precision with those measured by commercial scanning electron microscopes.
- 30 March 2007
- Published by Taylor & Francis in International Journal of Optomechatronics
- Vol. 1 (1) , 27-45
Open AccessBeam Scanning Confocal Differential Heterodyne Interferometry
This article presents a new approach to the design of confocal differential heterodyne interferometer (CDHI), which is a combination of differential heterodyne interferometer (DHI) with confocal laser scanning microscopy (CLSM). The CDHI can measure a step height over a quarter of wavelength of the light source, which can not be accurately measured by DHI and CLSM, respectively. The approach is that it utilizes a beam-scanning method instead of transporting a sample to be measured. The measurement results carried out for samples having step height are found to be comparable in precision with those measured by commercial scanning electron microscopes.