Petro M. Darmoris
Petro M. Darmoris has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Василь Ярославович Бунько
Separated Subdivision of National University of Life and Environmental Sciences of Ukraine «Berezhany Agrotechnical Institute», 20, Akademichna Str., Berezhany, Ternopil region, 47501, Ukraine
3 shared publications - Volodymyr Kozyrskyi
ALOTEK Technology sp.z.o.o., Zadabrowie 311, Krakowska 11, 37-716, Orly, Poland
1 shared publication - Назарій Васильович Бунько1 shared publication
- Олександр Ярославович Кондрат1 shared publication
Latest Publications
- Open Access
- 2 May 2026
- Published by National Technical University Kharkiv Polytechnic Institute in Electrical Engineering & Electromechanics
- No. 3,p. 18-25
Determination of the transition resistance of detachable electrical contacts with Camital active grease
Problem. The reliability of detachable electrical contact connections is significantly reduced due to an increase in transition electrical resistance caused by thermomechanical deformations, oxidation of contact surfaces, and a decrease in the effective contact area during operation. According to the results of operational and experimental studies, failures associated with contact degradation account for up to a third of the total number of electrical installation failures. Traditional methods, in particular the use of passive conductive lubricants, mostly only slow down oxidation processes and do not ensure active restoration of the contact condition. In this regard, it is important to develop models and technical solutions capable of describing and ensuring the stabilisation of the transition resistance of electrical contacts through controlled thermomechanical processes in the contact zone. Goal. To establish the regularities and interrelationships of processes in electrical contacts through experimental research and mathematical modelling of the evolution of the transition resistance of contact connections with composite grease modified with Cu–Al–Mn (Camital) with shape memory, taking into account the interaction of electrical, thermal, thermomechanical and tribological processes in normal and emergency operating modes. Methodology. Experimental studies were performed on models of bolted contact connections of aluminum busbars using composite grease containing 5 % and 10 % Cu–Al–Mn powder by volume, as well as on control samples without grease. Long-term measurements of contact resistance were carried out at a constant temperature and under periodic thermal loads. The theoretical study is based on a multilevel mathematical model, the numerical solution of which was carried out using implicit stable methods with parameter identification based on experimental data. Results. A decrease and stabilisation of contact resistance was established when using composite lubricant, most pronounced at a Cu–Al–Mn powder content of 10 % by volume. A reduced model of contact resistance evolution was proposed. Scientific novelty. For the first time, a generalised mathematical model of a detachable electrical contact with active composite lubricant has been developed, which takes into account the phase transformations of Cu–Al–Mn alloy particles and the mechanism of thermomechanical destruction of oxide films. The possibility of a step-like decrease in contact resistance under impulse currents is shown. Practical value. The results obtained can be used to improve the reliability of detachable electrical contact connections, predict changes in contact resistance during operation, and justify the choice of the composition of active electrical contact lubricants. References 37, tables 4, figures 7.
- 2 May 2026
- Published by National Technical University Kharkiv Polytechnic Institute in Electrical Engineering & Electromechanics
- No. 3,p. 18-25
Open AccessDetermination of the transition resistance of detachable electrical contacts with Camital active grease
Problem. The reliability of detachable electrical contact connections is significantly reduced due to an increase in transition electrical resistance caused by thermomechanical deformations, oxidation of contact surfaces, and a decrease in the effective contact area during operation. According to the results of operational and experimental studies, failures associated with contact degradation account for up to a third of the total number of electrical installation failures. Traditional methods, in particular the use of passive conductive lubricants, mostly only slow down oxidation processes and do not ensure active restoration of the contact condition. In this regard, it is important to develop models and technical solutions capable of describing and ensuring the stabilisation of the transition resistance of electrical contacts through controlled thermomechanical processes in the contact zone. Goal. To establish the regularities and interrelationships of processes in electrical contacts through experimental research and mathematical modelling of the evolution of the transition resistance of contact connections with composite grease modified with Cu–Al–Mn (Camital) with shape memory, taking into account the interaction of electrical, thermal, thermomechanical and tribological processes in normal and emergency operating modes. Methodology. Experimental studies were performed on models of bolted contact connections of aluminum busbars using composite grease containing 5 % and 10 % Cu–Al–Mn powder by volume, as well as on control samples without grease. Long-term measurements of contact resistance were carried out at a constant temperature and under periodic thermal loads. The theoretical study is based on a multilevel mathematical model, the numerical solution of which was carried out using implicit stable methods with parameter identification based on experimental data. Results. A decrease and stabilisation of contact resistance was established when using composite lubricant, most pronounced at a Cu–Al–Mn powder content of 10 % by volume. A reduced model of contact resistance evolution was proposed. Scientific novelty. For the first time, a generalised mathematical model of a detachable electrical contact with active composite lubricant has been developed, which takes into account the phase transformations of Cu–Al–Mn alloy particles and the mechanism of thermomechanical destruction of oxide films. The possibility of a step-like decrease in contact resistance under impulse currents is shown. Practical value. The results obtained can be used to improve the reliability of detachable electrical contact connections, predict changes in contact resistance during operation, and justify the choice of the composition of active electrical contact lubricants. References 37, tables 4, figures 7.
- 16 May 2025
- Published by Publishing House Helvetica (Publications) in Електротехнічні та інформаційні системи
- No. 107,p. 3-8
ДОСЛІДЖЕННЯ ТА АНАЛІЗ РОБОТИ МІКРОПРОЦЕСОРНОГО ТЕРМІНАЛУ В РЕЖИМІ НАПРАВЛЕНОГО СТРУМОВОГО ЗАХИСТУ
У статті розглянуто питання щодо дослідження та аналізу роботи мікропроцесорного терміналу, який використовується в системі релейного захисту та автоматики й володіє низкою функціональних можливостей для струмового захисту трансформаторів, ліній електропередач напругою до 6–35 кВ та іншого устаткування електроенергетичних систем.У роботі представлено схему керування для дослідження та налаштування мікропроцесорного термі- налу як виконавчого елемента, що забезпечує підвищення надійності системи релейного захисту й авто- матизацій станцій, підстанцій та електричних мереж.Ця схема використовується в лабораторних умовах під час дослідження максимально-струмового захисту (МСЗ), струмової відсічки (СВ), автоматичного повторного вмикання (АПВ), а також передбачає дослідження направленого максимально-струмового захисту, логічного захисту шин, направленого захис- ту замикань на землю та інші функції, які забезпечують надійність роботи системи електропостачання загалом.У дослідженнях мікропроцесорного пристрою використовуються елементи навантаження за мінімаль- них струмів, які дозволяють проводити налаштування всіх можливих варіантів конфігурації пристрою.Така система щодо дослідження інтелектуального пристрою використовується разом із програмним забезпеченням «Монітор-2» та призначена для віддаленого керування терміналом, а також керування на вищому рівні з метою встановлення відповідних ступенів захисту по струму, напрузі та ефективності використання цього пристрою в загальній системі релейного захисту та автоматики, яка є невід’ємною частиною роботи електричної мережі.Результати досліджень показали ефективність використання мікропроцесорного терміналу, який впроваджений у реальних умовах роботи електричних станцій, підстанцій та мереж.
- 16 May 2025
- Published by Publishing House Helvetica (Publications) in Електротехнічні та інформаційні системи
- No. 107,p. 3-8
ДОСЛІДЖЕННЯ ТА АНАЛІЗ РОБОТИ МІКРОПРОЦЕСОРНОГО ТЕРМІНАЛУ В РЕЖИМІ НАПРАВЛЕНОГО СТРУМОВОГО ЗАХИСТУ
У статті розглянуто питання щодо дослідження та аналізу роботи мікропроцесорного терміналу, який використовується в системі релейного захисту та автоматики й володіє низкою функціональних можливостей для струмового захисту трансформаторів, ліній електропередач напругою до 6–35 кВ та іншого устаткування електроенергетичних систем.У роботі представлено схему керування для дослідження та налаштування мікропроцесорного термі- налу як виконавчого елемента, що забезпечує підвищення надійності системи релейного захисту й авто- матизацій станцій, підстанцій та електричних мереж.Ця схема використовується в лабораторних умовах під час дослідження максимально-струмового захисту (МСЗ), струмової відсічки (СВ), автоматичного повторного вмикання (АПВ), а також передбачає дослідження направленого максимально-струмового захисту, логічного захисту шин, направленого захис- ту замикань на землю та інші функції, які забезпечують надійність роботи системи електропостачання загалом.У дослідженнях мікропроцесорного пристрою використовуються елементи навантаження за мінімаль- них струмів, які дозволяють проводити налаштування всіх можливих варіантів конфігурації пристрою.Така система щодо дослідження інтелектуального пристрою використовується разом із програмним забезпеченням «Монітор-2» та призначена для віддаленого керування терміналом, а також керування на вищому рівні з метою встановлення відповідних ступенів захисту по струму, напрузі та ефективності використання цього пристрою в загальній системі релейного захисту та автоматики, яка є невід’ємною частиною роботи електричної мережі.Результати досліджень показали ефективність використання мікропроцесорного терміналу, який впроваджений у реальних умовах роботи електричних станцій, підстанцій та мереж.
- 1 January 2023
- Published by Admiral Makarov National University of Shipbuilding in Collection of Scientific Publications NUS
- Vol. 490 (1) , 135-142
RESEARCH OF INTELLIGENT TERMINAL FOR RELAY PROTECTION AND AUTOMATION OF ENERGY SUPPLY SYSTEMS
- 1 January 2023
- Published by Admiral Makarov National University of Shipbuilding in Collection of Scientific Publications NUS
- Vol. 490 (1) , 135-142
RESEARCH OF INTELLIGENT TERMINAL FOR RELAY PROTECTION AND AUTOMATION OF ENERGY SUPPLY SYSTEMS