Siddharth Durgaprasad Sharma
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Siddharth Durgaprasad Sharma has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Somnath Roy
Indian Institute of Technology Kharagpur
4 shared publications - Chandan Bose
University of Birmingham
2 shared publications - Debajyoti Kumar2 shared publications
- Piru Mohan Khan
Department of Applied Mechanics, Indian Institute of Technology Delhi , New Delhi
2 shared publications - Suman Chakraborty
Indian Institute of Technology Kharagpur
2 shared publications
Latest Publications
- Open Access
- 20 February 2026
- Published by Elsevier in SSRN Electronic Journal
GPU optimized integration of immersed boundary method and overset mesh framework for moving boundary problems
This paper focuses on a GPU-optimized overset grid framework coupled with a sharp-interface Immersed Boundary Method (IBM) for high-fidelity simulation of incompressible flows involving moving bodies, multi-body interactions, and complex geometries. The method addresses long-standing limitations of overset IBM, such as expensive hole-cutting, donor-search operations, and poor scalability, by leveraging a lightweight sliding-window block reallocation strategy, minimalistic interface maps, and flux-preserving interpolation between coarse and refined meshes. A combined Array-of-Structures / Structure-of-Arrays data structure is devised for efficient management and storage of multiple blocks of the domain. Explicit OpenACC directives leveraging the unified memory architecture enable GPU acceleration. At the same time, a dual-level OpenMP–OpenACC parallelism assigns each overset block to a dedicated GPU, enabling multi-GPU execution without message-passing overhead. The solver is validated and verified across a wide range of canonical and complex cases, including flow past cylinders and spheres, sedimentation of smooth and rough particles, and fluttering plates, with results demonstrating second-order accuracy, local and global mass conservation, and excellent agreement with experimental and numerical benchmarks. High-Reynolds-number propeller simulations confirm DNS-level resolution, with the overset mesh adequately capturing Kolmogorov scales. Multi-body demonstrations involving two flapping robotic butterflies following independent sinusoidal trajectories highlight robust block autonomy and accurate vortex-interaction dynamics. Overall, the proposed framework achieves close to 200× speedup relative to single-core CPU execution, retains accuracy while using significantly fewer grid points than uniform DNS meshes, scales efficiently across multiple GPUs, and establishes a versatile, scalable methodology for simulating turbulent, bio-inspired, and strongly unsteady moving-body flows.
- 20 February 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessGPU optimized integration of immersed boundary method and overset mesh framework for moving boundary problems
This paper focuses on a GPU-optimized overset grid framework coupled with a sharp-interface Immersed Boundary Method (IBM) for high-fidelity simulation of incompressible flows involving moving bodies, multi-body interactions, and complex geometries. The method addresses long-standing limitations of overset IBM, such as expensive hole-cutting, donor-search operations, and poor scalability, by leveraging a lightweight sliding-window block reallocation strategy, minimalistic interface maps, and flux-preserving interpolation between coarse and refined meshes. A combined Array-of-Structures / Structure-of-Arrays data structure is devised for efficient management and storage of multiple blocks of the domain. Explicit OpenACC directives leveraging the unified memory architecture enable GPU acceleration. At the same time, a dual-level OpenMP–OpenACC parallelism assigns each overset block to a dedicated GPU, enabling multi-GPU execution without message-passing overhead. The solver is validated and verified across a wide range of canonical and complex cases, including flow past cylinders and spheres, sedimentation of smooth and rough particles, and fluttering plates, with results demonstrating second-order accuracy, local and global mass conservation, and excellent agreement with experimental and numerical benchmarks. High-Reynolds-number propeller simulations confirm DNS-level resolution, with the overset mesh adequately capturing Kolmogorov scales. Multi-body demonstrations involving two flapping robotic butterflies following independent sinusoidal trajectories highlight robust block autonomy and accurate vortex-interaction dynamics. Overall, the proposed framework achieves close to 200× speedup relative to single-core CPU execution, retains accuracy while using significantly fewer grid points than uniform DNS meshes, scales efficiently across multiple GPUs, and establishes a versatile, scalable methodology for simulating turbulent, bio-inspired, and strongly unsteady moving-body flows.
- 1 January 2024
- Published by AIP Publishing in Physics of Fluids
- Vol. 36 (1)
Effects of hematocrit levels on flow structures and stress levels in the healthy and diseased carotid arteries
Flow structures and wall shear stress (WSS) distribution in human arteries depend strongly on blood rheology. Blood viscosity undergoes significant alterations due to varying hematocrit (Hct) levels. Hematocrit levels can change from the normal level (45%) due to numerous disorders such as leukemia, lymphoma, and congenital heart disease. However, the effects of Hct levels on the flow features and WSS levels in large stenotic arteries are not well reported in literature. The present study computationally assesses the variation in flow features in healthy and stenosed carotid arteries due to changes in blood Hct levels. We have reported variations in axial and secondary flow characteristics, vortex structures, and WSS-based parameters for different Hct levels. Specifically, we consider high (65%) and low (25%) Hct levels in addition to a normal Hct level. Our results reveal that both high and low Hct levels have adverse effects on the hemodynamic features inside a healthy carotid artery model. The low Hct level displays a much more widespread low time-averaged WSS (TAWSS) area, while the high Hct shows an increased oscillatory shear index (OSI) zone at the carotid sinus wall. In stenotic arteries, low Hct enhances the spread of the low TAWSS zone in the post-stenotic carotid sinus, whereas high Hct increases the risk of plaque rupture. The high Hct level also increases the spread of high OSI zone at the inner wall of internal carotid artery for the moderately stenosed artery.
- 1 January 2024
- Published by AIP Publishing in Physics of Fluids
- Vol. 36 (1)
Effects of hematocrit levels on flow structures and stress levels in the healthy and diseased carotid arteries
Flow structures and wall shear stress (WSS) distribution in human arteries depend strongly on blood rheology. Blood viscosity undergoes significant alterations due to varying hematocrit (Hct) levels. Hematocrit levels can change from the normal level (45%) due to numerous disorders such as leukemia, lymphoma, and congenital heart disease. However, the effects of Hct levels on the flow features and WSS levels in large stenotic arteries are not well reported in literature. The present study computationally assesses the variation in flow features in healthy and stenosed carotid arteries due to changes in blood Hct levels. We have reported variations in axial and secondary flow characteristics, vortex structures, and WSS-based parameters for different Hct levels. Specifically, we consider high (65%) and low (25%) Hct levels in addition to a normal Hct level. Our results reveal that both high and low Hct levels have adverse effects on the hemodynamic features inside a healthy carotid artery model. The low Hct level displays a much more widespread low time-averaged WSS (TAWSS) area, while the high Hct shows an increased oscillatory shear index (OSI) zone at the carotid sinus wall. In stenotic arteries, low Hct enhances the spread of the low TAWSS zone in the post-stenotic carotid sinus, whereas high Hct increases the risk of plaque rupture. The high Hct level also increases the spread of high OSI zone at the inner wall of internal carotid artery for the moderately stenosed artery.
- Open Access
- 1 June 2023
- Published by AIP Publishing in Physics of Fluids
- Vol. 35 (6)
Effect of heart rate on the hemodynamics in healthy and stenosed carotid arteries
Stenosis in the internal carotid arteries is a serious cardiovascular condition. It is well-reported that low and oscillatory wall shear stress enhances the risk of stenosis progression. However, the effects of increased heart rates in highly stenosed arteries are not well explored. A detailed understanding of the flow features and stress distribution in stenosed carotid arteries at different heart rates may help clinicians to prescribe better exercise schedules for patients. In this study, we probe the effects of elevated heart rates on the hemodynamics in healthy and stenosed carotid arterial geometries using an immersed boundary method-based computational framework. Our results reveal that a strong recirculation, secondary velocity, and oscillatory shear index (OSI) zone develop inside a severely stenosed carotid artery at normal heart rate. Higher heart rates may potentially improve arterial health by reducing OSI only for the healthy and mild stenosis carotid arteries. However, the increased heart rates worsen the arterial health of severely stenosed arteries by onsetting flow instabilities, enhancing the spread and severity of the recirculation zone and the magnitude of the secondary velocity, the pressure drops across the stenosis, and the spread of high OSI (≥0.2) zone downstream. Furthermore, in the case of severe stenosis, the wall shear stress at the stenosis throat rises significantly, which can contribute to plaque rupture and thrombus development. Here, we report in detail the behavior of stress levels and pressure fluctuations in the carotid artery model at different stenosis levels for normal and elevated heart rates.
- 1 June 2023
- Published by AIP Publishing in Physics of Fluids
- Vol. 35 (6)
Open AccessEffect of heart rate on the hemodynamics in healthy and stenosed carotid arteries
Stenosis in the internal carotid arteries is a serious cardiovascular condition. It is well-reported that low and oscillatory wall shear stress enhances the risk of stenosis progression. However, the effects of increased heart rates in highly stenosed arteries are not well explored. A detailed understanding of the flow features and stress distribution in stenosed carotid arteries at different heart rates may help clinicians to prescribe better exercise schedules for patients. In this study, we probe the effects of elevated heart rates on the hemodynamics in healthy and stenosed carotid arterial geometries using an immersed boundary method-based computational framework. Our results reveal that a strong recirculation, secondary velocity, and oscillatory shear index (OSI) zone develop inside a severely stenosed carotid artery at normal heart rate. Higher heart rates may potentially improve arterial health by reducing OSI only for the healthy and mild stenosis carotid arteries. However, the increased heart rates worsen the arterial health of severely stenosed arteries by onsetting flow instabilities, enhancing the spread and severity of the recirculation zone and the magnitude of the secondary velocity, the pressure drops across the stenosis, and the spread of high OSI (≥0.2) zone downstream. Furthermore, in the case of severe stenosis, the wall shear stress at the stenosis throat rises significantly, which can contribute to plaque rupture and thrombus development. Here, we report in detail the behavior of stress levels and pressure fluctuations in the carotid artery model at different stenosis levels for normal and elevated heart rates.