Khan Siddiqui
Khan Siddiqui has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Ahmed Altaf
Department of Surgery, Section of Neurosurgery, Aga Khan University Hospital, Karachi, Pakistan
3 shared publications - Edmond Knopp
Department of Radiology, Hyperfine, Guilford, Connecticut, United States
3 shared publications - Syed Ather Enam
Section of Neurosurgery, Department of Surgery, Aga Khan University Hospital, Karachi, Pakistan; Center of Oncological Research in Surgery, Aga Khan University Hospital, Karachi, Pakistan
3 shared publications - Fatima Mubarak
Department of Radiology, Aga Khan University, Karachi, Sindh, Pakistan
2 shared publications - Muhammad Shakir
University of Missouri
2 shared publications - Aabiya Arif
Department of Neurosurgery, Ziauddin University, Karachi, Pakistan
1 shared publication
Latest Publications
- Open Access
- 28 June 2024
- Published by Scientific Scholar in Surgical Neurology International
- Vol. 15, 218
Applications, limitations and advancements of ultra-low-field magnetic resonance imaging: A scoping review
Background: Ultra-low-field magnetic resonance imaging (ULF-MRI) has emerged as an alternative with several portable clinical applications. This review aims to comprehensively explore its applications, potential limitations, technological advancements, and expert recommendations. Methods: A review of the literature was conducted across medical databases to identify relevant studies. Articles on clinical usage of ULF-MRI were included, and data regarding applications, limitations, and advancements were extracted. A total of 25 articles were included for qualitative analysis. Results: The review reveals ULF-MRI efficacy in intensive care settings and intraoperatively. Technological strides are evident through innovative reconstruction techniques and integration with machine learning approaches. Additional advantages include features such as portability, cost-effectiveness, reduced power requirements, and improved patient comfort. However, alongside these strengths, certain limitations of ULF-MRI were identified, including low signal-to-noise ratio, limited resolution and length of scanning sequences, as well as variety and absence of regulatory-approved contrast-enhanced imaging. Recommendations from experts emphasize optimizing imaging quality, including addressing signal-to-noise ratio (SNR) and resolution, decreasing the length of scan time, and expanding point-of-care magnetic resonance imaging availability. Conclusion: This review summarizes the potential of ULF-MRI. The technology’s adaptability in intensive care unit settings and its diverse clinical and surgical applications, while accounting for SNR and resolution limitations, highlight its significance, especially in resource-limited settings. Technological advancements, alongside expert recommendations, pave the way for refining and expanding ULF-MRI’s utility. However, adequate training is crucial for widespread utilization.
- 28 June 2024
- Published by Scientific Scholar in Surgical Neurology International
- Vol. 15, 218
Open AccessApplications, limitations and advancements of ultra-low-field magnetic resonance imaging: A scoping review
Background: Ultra-low-field magnetic resonance imaging (ULF-MRI) has emerged as an alternative with several portable clinical applications. This review aims to comprehensively explore its applications, potential limitations, technological advancements, and expert recommendations. Methods: A review of the literature was conducted across medical databases to identify relevant studies. Articles on clinical usage of ULF-MRI were included, and data regarding applications, limitations, and advancements were extracted. A total of 25 articles were included for qualitative analysis. Results: The review reveals ULF-MRI efficacy in intensive care settings and intraoperatively. Technological strides are evident through innovative reconstruction techniques and integration with machine learning approaches. Additional advantages include features such as portability, cost-effectiveness, reduced power requirements, and improved patient comfort. However, alongside these strengths, certain limitations of ULF-MRI were identified, including low signal-to-noise ratio, limited resolution and length of scanning sequences, as well as variety and absence of regulatory-approved contrast-enhanced imaging. Recommendations from experts emphasize optimizing imaging quality, including addressing signal-to-noise ratio (SNR) and resolution, decreasing the length of scan time, and expanding point-of-care magnetic resonance imaging availability. Conclusion: This review summarizes the potential of ULF-MRI. The technology’s adaptability in intensive care unit settings and its diverse clinical and surgical applications, while accounting for SNR and resolution limitations, highlight its significance, especially in resource-limited settings. Technological advancements, alongside expert recommendations, pave the way for refining and expanding ULF-MRI’s utility. However, adequate training is crucial for widespread utilization.
- Open Access
- 6 October 2023
- Published by Scientific Scholar in Surgical Neurology International
- Vol. 14, 357
Intraoperative use of low-field magnetic resonance imaging for brain tumors: A systematic review
Background: Low-field magnetic resonance imaging (LF-MRI) has become a valuable tool in the diagnosis of brain tumors due to its high spatial resolution and ability to acquire images in a short amount of time. However, the use of LF-MRI for intraoperative imaging during brain tumor surgeries has not been extensively studied. The aim of this systematic review is to investigate the impact of low-field intraoperative magnetic resonance imaging (LF-IMRI) on the duration of brain tumor surgery and the extent of tumor resection. Methods: A comprehensive literature search was conducted using PubMed, Scopus, and Google Scholar from February 2000 to December 2022. The studies were selected based on the inclusion criteria and reviewed independently by two reviewers. The gathered information was organized and analyzed using Excel. Results: Our review of 21 articles found that low-field intraoperative MRI (LF-IMRI) with a field below 0.3T was used in most of the studies, specifically 15 studies used 0.15T LF-IMRI. The T1-weighted sequence was the most frequently reported, and the average scanning time was 24.26 min. The majority of the studies reported a positive impact of LF-IMRI on the extent of tumor resection, with an increase ranging from 11% to 52.5%. Notably, there were no studies describing the use of ultra-low-field (ULF) intraoperative MRI. Conclusion: The results of this systematic review will aid neurosurgeons and neuroradiologists in making informed decisions about the use of LF-MRI in brain tumor surgeries. Further, research is needed to fully understand the impact of LF-MRI in brain tumor surgeries and to optimize its use in the clinical setting. There is an opportunity to study the utility of ULF-MRI in brain tumor surgeries.
- 6 October 2023
- Published by Scientific Scholar in Surgical Neurology International
- Vol. 14, 357
Open AccessIntraoperative use of low-field magnetic resonance imaging for brain tumors: A systematic review
Background: Low-field magnetic resonance imaging (LF-MRI) has become a valuable tool in the diagnosis of brain tumors due to its high spatial resolution and ability to acquire images in a short amount of time. However, the use of LF-MRI for intraoperative imaging during brain tumor surgeries has not been extensively studied. The aim of this systematic review is to investigate the impact of low-field intraoperative magnetic resonance imaging (LF-IMRI) on the duration of brain tumor surgery and the extent of tumor resection. Methods: A comprehensive literature search was conducted using PubMed, Scopus, and Google Scholar from February 2000 to December 2022. The studies were selected based on the inclusion criteria and reviewed independently by two reviewers. The gathered information was organized and analyzed using Excel. Results: Our review of 21 articles found that low-field intraoperative MRI (LF-IMRI) with a field below 0.3T was used in most of the studies, specifically 15 studies used 0.15T LF-IMRI. The T1-weighted sequence was the most frequently reported, and the average scanning time was 24.26 min. The majority of the studies reported a positive impact of LF-IMRI on the extent of tumor resection, with an increase ranging from 11% to 52.5%. Notably, there were no studies describing the use of ultra-low-field (ULF) intraoperative MRI. Conclusion: The results of this systematic review will aid neurosurgeons and neuroradiologists in making informed decisions about the use of LF-MRI in brain tumor surgeries. Further, research is needed to fully understand the impact of LF-MRI in brain tumor surgeries and to optimize its use in the clinical setting. There is an opportunity to study the utility of ULF-MRI in brain tumor surgeries.
- Open Access
- 23 June 2023
- Published by Scientific Scholar in Surgical Neurology International
- Vol. 14, 212
Intraoperative use of ultra-low-field, portable magnetic resonance imaging – first report
Background: Intraoperative use of portable magnetic resonance imaging (pMRI) has become a valuable tool in a surgeon’s arsenal since its inception. It allows intraoperative localization of tumor extent and identification of residual disease, hence maximizing tumor resection. Its utility has been widespread in high-income countries for the past 20 years, but in lower-middle-income countries (LMIC), it is still not widely available due to several reasons, including cost constraints. The use of intraoperative pMRI may be a cost-effective and efficient substitute for conventional MRI machines. The authors present a case where a pMRI device was used intraoperatively in an LMIC setting. Case Description: The authors performed a microscopic transsphenoidal resection of a sellar lesion with intraoperative imaging using the pMRI system on a 45-year-old man with a nonfunctioning pituitary macroadenoma. Without the need for an MRI suite or other MRI-compatible equipment, the scan was conducted within the confinements of a standard operating room. Low-field MRI showed some residual disease and postsurgical changes, comparable to postoperative high-field MRI. Conclusion: To the best of our knowledge, our report provides the first documented successful intraoperative transsphenoidal resection of a pituitary adenoma using an ultra-low-field pMRI device. The device can potentially enhance neurosurgical capacity in resource-constrained settings and improve patient outcomes in developing country.
- 23 June 2023
- Published by Scientific Scholar in Surgical Neurology International
- Vol. 14, 212
Open AccessIntraoperative use of ultra-low-field, portable magnetic resonance imaging – first report
Background: Intraoperative use of portable magnetic resonance imaging (pMRI) has become a valuable tool in a surgeon’s arsenal since its inception. It allows intraoperative localization of tumor extent and identification of residual disease, hence maximizing tumor resection. Its utility has been widespread in high-income countries for the past 20 years, but in lower-middle-income countries (LMIC), it is still not widely available due to several reasons, including cost constraints. The use of intraoperative pMRI may be a cost-effective and efficient substitute for conventional MRI machines. The authors present a case where a pMRI device was used intraoperatively in an LMIC setting. Case Description: The authors performed a microscopic transsphenoidal resection of a sellar lesion with intraoperative imaging using the pMRI system on a 45-year-old man with a nonfunctioning pituitary macroadenoma. Without the need for an MRI suite or other MRI-compatible equipment, the scan was conducted within the confinements of a standard operating room. Low-field MRI showed some residual disease and postsurgical changes, comparable to postoperative high-field MRI. Conclusion: To the best of our knowledge, our report provides the first documented successful intraoperative transsphenoidal resection of a pituitary adenoma using an ultra-low-field pMRI device. The device can potentially enhance neurosurgical capacity in resource-constrained settings and improve patient outcomes in developing country.