Shuai Shao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Shuai Shao has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Bo Liu
Women and Children’s Hospital of Dalian University of Technology
7 shared publications - Hangyu Zhang
Faculty of Medicine, Dalian University of Technology, Dalian 116024, China
4 shared publications - Na Li
Central Hospital of Dalian University of Technology, Dalian 116033, China
4 shared publications - Zhengyao Zhang
School of Chemical Engineering, Ocean and Life Sciences, Dalian University of Technology, Panjin 124221, China
4 shared publications - Angyang Shang
Central Hospital of Dalian University of Technology, Dalian 116021, China
2 shared publications - Jiaqi Liu
Central Hospital, Dalian University of Technology, Dalian 116021, China
2 shared publications
Latest Publications
- Open Access
Affinity Peptide-Based Circularly Permuted Fluorescent Protein Biosensors Loaded in a Microfluidic System for Systemic Lupus Erythematosus Diagnosis
Systemic lupus erythematosus (SLE) is a chronic autoimmune disease, with anti-double-stranded DNA (anti-dsDNA) antibodies as its serological biomarkers. However, conventional anti-dsDNA antibody detection methods, which mainly rely on antibody-binding assays, often suffer from limited sensitivity and specificity, cumbersome procedures, and poor suitability for accurate clinical analysis. Herein, we developed an integrated detection system combining a circularly permuted fluorescent protein (cpFP)-based biosensor with a microfluidic chip for rapid and reliable anti-dsDNA antibody detection. The biosensor, cpR-dsAb-C1, was engineered from mApple by inserting an affinity peptide identified through phage display, enabling specific recognition of the variable region of anti-dsDNA antibodies. The biosensor exhibited good sensitivity, specificity, and anti-interference capability. Furthermore, integration of cpR-dsAb-C1 with a polydimethylsiloxane (PDMS)-based microfluidic chip yielded a microfluidic detection platform with good linearity for rapid antibody analysis. Clinical validation showed significantly higher anti-dsDNA antibody levels in patients with SLE than in healthy controls, and the results were consistent with those obtained using routine clinical methods, with an accuracy exceeding 95%. Overall, this system provides a promising low-cost, efficient, and accurate strategy for the early diagnosis and dynamic monitoring of SLE.
Open AccessAffinity Peptide-Based Circularly Permuted Fluorescent Protein Biosensors Loaded in a Microfluidic System for Systemic Lupus Erythematosus Diagnosis
Systemic lupus erythematosus (SLE) is a chronic autoimmune disease, with anti-double-stranded DNA (anti-dsDNA) antibodies as its serological biomarkers. However, conventional anti-dsDNA antibody detection methods, which mainly rely on antibody-binding assays, often suffer from limited sensitivity and specificity, cumbersome procedures, and poor suitability for accurate clinical analysis. Herein, we developed an integrated detection system combining a circularly permuted fluorescent protein (cpFP)-based biosensor with a microfluidic chip for rapid and reliable anti-dsDNA antibody detection. The biosensor, cpR-dsAb-C1, was engineered from mApple by inserting an affinity peptide identified through phage display, enabling specific recognition of the variable region of anti-dsDNA antibodies. The biosensor exhibited good sensitivity, specificity, and anti-interference capability. Furthermore, integration of cpR-dsAb-C1 with a polydimethylsiloxane (PDMS)-based microfluidic chip yielded a microfluidic detection platform with good linearity for rapid antibody analysis. Clinical validation showed significantly higher anti-dsDNA antibody levels in patients with SLE than in healthy controls, and the results were consistent with those obtained using routine clinical methods, with an accuracy exceeding 95%. Overall, this system provides a promising low-cost, efficient, and accurate strategy for the early diagnosis and dynamic monitoring of SLE.
- 30 April 2026
- Published by Elsevier in Cellular Signalling
- Vol. 145, 112564
The dual role of kindlin-2 in mechanotransduction: A bridge for sensing and a hub for signaling
- 30 April 2026
- Published by Elsevier in Cellular Signalling
- Vol. 145, 112564
The dual role of kindlin-2 in mechanotransduction: A bridge for sensing and a hub for signaling
- Open Access
Affinity Peptide-Based Circularly Permuted Fluorescent Protein Biosensors for Non-Small Cell Lung Cancer Diagnosis
Non-small cell lung cancer (NSCLC) is the predominant form of lung cancer and poses a significant public health challenge. Early detection is crucial for improving patient outcomes, with serum biomarkers such as carcinoembryonic antigen (CEA), squamous cell carcinoma antigen (SCCAg), and cytokeratin fragment 19 (CYFRA 21-1) playing a critical role in early screening and pathological classification of NSCLC. However, due to being mainly based on corresponding antibody binding reactions, existing detection technologies for these serum biomarkers have shortcomings such as complex operations, high false positive rates, and high costs. This study aimed to develop new methods for detecting CEA, SCCAg, and CYFRA 21-1 to assist in the diagnosis of NSCLC. Affinity peptides of CEA, SCCAg, and CYFRA 21-1, respectively, were screened by phage display technology, and the peptides’ binding affinities were determined by enzyme-linked immunosorbent assay and biolayer interferometry. Peptides with high affinity were then integrated as binding domains into biosensors by fusing them with circularly permuted fluorescent proteins (cpFPs) through genetic coding. The resulting biosensors, C4 biosensor for CEA, S1 biosensor for SCCAg, and Y3 biosensor for CYFRA 21-1, demonstrated robust sensitivity and specificity even at concentrations as low as 1 ng/mL for their respective tumor markers. When applied to clinical samples and recalibrated for the upper limit of normal concentrations, the biosensors exhibited enhanced sensitivity and specificity for NSCLC diagnosis. This study introduced innovative biosensors for the detection of CEA, SCCAg, and CYFRA 21-1, providing a highly sensitive, specific, rapid, and cost-effective diagnostic alternative that could significantly improve NSCLC screening rates.
Open AccessAffinity Peptide-Based Circularly Permuted Fluorescent Protein Biosensors for Non-Small Cell Lung Cancer Diagnosis
Non-small cell lung cancer (NSCLC) is the predominant form of lung cancer and poses a significant public health challenge. Early detection is crucial for improving patient outcomes, with serum biomarkers such as carcinoembryonic antigen (CEA), squamous cell carcinoma antigen (SCCAg), and cytokeratin fragment 19 (CYFRA 21-1) playing a critical role in early screening and pathological classification of NSCLC. However, due to being mainly based on corresponding antibody binding reactions, existing detection technologies for these serum biomarkers have shortcomings such as complex operations, high false positive rates, and high costs. This study aimed to develop new methods for detecting CEA, SCCAg, and CYFRA 21-1 to assist in the diagnosis of NSCLC. Affinity peptides of CEA, SCCAg, and CYFRA 21-1, respectively, were screened by phage display technology, and the peptides’ binding affinities were determined by enzyme-linked immunosorbent assay and biolayer interferometry. Peptides with high affinity were then integrated as binding domains into biosensors by fusing them with circularly permuted fluorescent proteins (cpFPs) through genetic coding. The resulting biosensors, C4 biosensor for CEA, S1 biosensor for SCCAg, and Y3 biosensor for CYFRA 21-1, demonstrated robust sensitivity and specificity even at concentrations as low as 1 ng/mL for their respective tumor markers. When applied to clinical samples and recalibrated for the upper limit of normal concentrations, the biosensors exhibited enhanced sensitivity and specificity for NSCLC diagnosis. This study introduced innovative biosensors for the detection of CEA, SCCAg, and CYFRA 21-1, providing a highly sensitive, specific, rapid, and cost-effective diagnostic alternative that could significantly improve NSCLC screening rates.
- Open Access
- 9 October 2024
- Published by MDPI AG in Biosensors
- Vol. 14 (10) , 489
Non-Invasive On–Off Fluorescent Biosensor for Endothelial Cell Detection
For rapid and convenient detection of living endothelial cells (ECs) specifically without immunostaining, we developed a biosensor based on turn-on fluorescent protein, named LV-EcpG. It includes a high-affinity peptide E12P obtained through phage display technology for specifically recognizing ECs and a turn-on EGFP fused with two linker peptides. The “on-off” switching mechanism of this genetically encoded fluorescent protein-based biosensor (FPB) ensured that fluorescence signals were activated only when binding with ECs, thus enabling these FPB characters for direct, visual, and non-invasive detection of ECs. Its specificity and multicolor imaging capability established LV-EcpG as a powerful tool for live EC research, with significant potential for diagnosing and treating cardiovascular diseases and tumor angiogenesis.
- 9 October 2024
- Published by MDPI AG in Biosensors
- Vol. 14 (10) , 489
Open AccessNon-Invasive On–Off Fluorescent Biosensor for Endothelial Cell Detection
For rapid and convenient detection of living endothelial cells (ECs) specifically without immunostaining, we developed a biosensor based on turn-on fluorescent protein, named LV-EcpG. It includes a high-affinity peptide E12P obtained through phage display technology for specifically recognizing ECs and a turn-on EGFP fused with two linker peptides. The “on-off” switching mechanism of this genetically encoded fluorescent protein-based biosensor (FPB) ensured that fluorescence signals were activated only when binding with ECs, thus enabling these FPB characters for direct, visual, and non-invasive detection of ECs. Its specificity and multicolor imaging capability established LV-EcpG as a powerful tool for live EC research, with significant potential for diagnosing and treating cardiovascular diseases and tumor angiogenesis.
- 1 October 2024
- Published by SAGE Publications in Tissue Engineering Part B: Reviews
- Vol. 30 (5) , 530-544
The Pathological Factors Involved in Current In Vitro Atherosclerotic Models
Cardiovascular disease stemmed from atherosclerosis is well recognized to be the predominant cause of global death. In order to comprehensively clarify the pathogenesis of atherosclerosis, exploit effective drugs as well as develop therapeutic solutions, various atherosclerotic models were constructed in vitro and widely utilized by scientific community. Compared with animal models, the in vitro atherosclerotic models play prominent role not only in the targeted research of single pathological factor related to atherosclerosis in the human derived system, but also in the combined study on multi-pathological factors leading to atherosclerosis, thereby contributing tremendously to the in-depth elucidation of atherosclerotic pathological process. In the current review, a variety of pathological factors incorporated into the existing atherosclerotic models in vitro are broadly elaborated, including the pathological mechanism, in vitro simulation approaches, and the desired improvement perspectives for reproducing each pathological factor. In addition, this review also summarizes the advantages and disadvantages of current atherosclerotic models as well as their potential functionality. Finally, the promising aspects for future atherosclerotic models in vitro with potential advances are also discussed.
- 1 October 2024
- Published by SAGE Publications in Tissue Engineering Part B: Reviews
- Vol. 30 (5) , 530-544
The Pathological Factors Involved in Current In Vitro Atherosclerotic Models
Cardiovascular disease stemmed from atherosclerosis is well recognized to be the predominant cause of global death. In order to comprehensively clarify the pathogenesis of atherosclerosis, exploit effective drugs as well as develop therapeutic solutions, various atherosclerotic models were constructed in vitro and widely utilized by scientific community. Compared with animal models, the in vitro atherosclerotic models play prominent role not only in the targeted research of single pathological factor related to atherosclerosis in the human derived system, but also in the combined study on multi-pathological factors leading to atherosclerosis, thereby contributing tremendously to the in-depth elucidation of atherosclerotic pathological process. In the current review, a variety of pathological factors incorporated into the existing atherosclerotic models in vitro are broadly elaborated, including the pathological mechanism, in vitro simulation approaches, and the desired improvement perspectives for reproducing each pathological factor. In addition, this review also summarizes the advantages and disadvantages of current atherosclerotic models as well as their potential functionality. Finally, the promising aspects for future atherosclerotic models in vitro with potential advances are also discussed.
- Open Access
- 24 July 2024
- Published by MDPI AG in Biosensors
- Vol. 14 (8) , 359
Far-Red Fluorescent Proteins: Tools for Advancing In Vivo Imaging
Far-red fluorescent proteins (FPs) have emerged as indispensable tools in in vivo imaging, playing a pivotal role in elucidating fundamental mechanisms and addressing application issues in biotechnology and biomedical fields. Their ability for deep penetration, coupled with reduced light scattering and absorption, robust resistance to autofluorescence, and diminished phototoxicity, has positioned far-red biosensors at the forefront of non-invasive visualization techniques for observing intracellular activities and intercellular behaviors. In this review, far-red FPs and their applications in living systems are mainly discussed. Firstly, various far-red FPs, characterized by emission peaks spanning from 600 nm to 650 nm, are introduced. This is followed by a detailed presentation of the fundamental principles enabling far-red biosensors to detect biomolecules and environmental changes. Furthermore, the review accentuates the superiority of far-red FPs in multi-color imaging. In addition, significant emphasis is placed on the value of far-red FPs in improving imaging resolution, highlighting their great contribution to the advancement of in vivo imaging.
- 24 July 2024
- Published by MDPI AG in Biosensors
- Vol. 14 (8) , 359
Open AccessFar-Red Fluorescent Proteins: Tools for Advancing In Vivo Imaging
Far-red fluorescent proteins (FPs) have emerged as indispensable tools in in vivo imaging, playing a pivotal role in elucidating fundamental mechanisms and addressing application issues in biotechnology and biomedical fields. Their ability for deep penetration, coupled with reduced light scattering and absorption, robust resistance to autofluorescence, and diminished phototoxicity, has positioned far-red biosensors at the forefront of non-invasive visualization techniques for observing intracellular activities and intercellular behaviors. In this review, far-red FPs and their applications in living systems are mainly discussed. Firstly, various far-red FPs, characterized by emission peaks spanning from 600 nm to 650 nm, are introduced. This is followed by a detailed presentation of the fundamental principles enabling far-red biosensors to detect biomolecules and environmental changes. Furthermore, the review accentuates the superiority of far-red FPs in multi-color imaging. In addition, significant emphasis is placed on the value of far-red FPs in improving imaging resolution, highlighting their great contribution to the advancement of in vivo imaging.
- Open Access
- 23 August 2023
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 24 (17) , 13110
Advances in Alzheimer’s Disease-Associated Aβ Therapy Based on Peptide
Alzheimer’s disease (AD) urgently needs innovative treatments due to the increasing aging population and lack of effective drugs and therapies. The amyloid fibrosis of AD-associated β-amyloid (Aβ) that could induce a series of cascades, such as oxidative stress and inflammation, is a critical factor in the progression of AD. Recently, peptide-based therapies for AD are expected to be great potential strategies for the high specificity to the targets, low toxicity, fast blood clearance, rapid cell and tissue permeability, and superior biochemical characteristics. Specifically, various chiral amino acids or peptide-modified interfaces draw much attention as effective manners to inhibit Aβ fibrillation. On the other hand, peptide-based inhibitors could be obtained through affinity screening such as phage display or by rational design based on the core sequence of Aβ fibrosis or by computer aided drug design based on the structure of Aβ. These peptide-based therapies can inhibit Aβ fibrillation and reduce cytotoxicity induced by Aβ aggregation and some have been shown to relieve cognition in AD model mice and reduce Aβ plaques in mice brains. This review summarizes the design method and characteristics of peptide inhibitors and their effect on the amyloid fibrosis of Aβ. We further describe some analysis methods for evaluating the inhibitory effect and point out the challenges in these areas, and possible directions for the design of AD drugs based on peptides, which lay the foundation for the development of new effective drugs in the future.
- 23 August 2023
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 24 (17) , 13110
Open AccessAdvances in Alzheimer’s Disease-Associated Aβ Therapy Based on Peptide
Alzheimer’s disease (AD) urgently needs innovative treatments due to the increasing aging population and lack of effective drugs and therapies. The amyloid fibrosis of AD-associated β-amyloid (Aβ) that could induce a series of cascades, such as oxidative stress and inflammation, is a critical factor in the progression of AD. Recently, peptide-based therapies for AD are expected to be great potential strategies for the high specificity to the targets, low toxicity, fast blood clearance, rapid cell and tissue permeability, and superior biochemical characteristics. Specifically, various chiral amino acids or peptide-modified interfaces draw much attention as effective manners to inhibit Aβ fibrillation. On the other hand, peptide-based inhibitors could be obtained through affinity screening such as phage display or by rational design based on the core sequence of Aβ fibrosis or by computer aided drug design based on the structure of Aβ. These peptide-based therapies can inhibit Aβ fibrillation and reduce cytotoxicity induced by Aβ aggregation and some have been shown to relieve cognition in AD model mice and reduce Aβ plaques in mice brains. This review summarizes the design method and characteristics of peptide inhibitors and their effect on the amyloid fibrosis of Aβ. We further describe some analysis methods for evaluating the inhibitory effect and point out the challenges in these areas, and possible directions for the design of AD drugs based on peptides, which lay the foundation for the development of new effective drugs in the future.
- Open Access
Visualization of Cell Membrane Tension Regulated by the Microfilaments as a “Shock Absorber” in Micropatterned Cells
The extracellular stress signal transmits along the cell membrane–cytoskeleton–focal adhesions (FAs) complex, regulating the cell function through membrane tension. However, the mechanism of the complex regulating membrane tension is still unclear. This study designed polydimethylsiloxane stamps with specific shapes to change the actin filaments’ arrangement and FAs’ distribution artificially in live cells, visualized the membrane tension in real time, and introduced the concept of information entropy to describe the order degree of the actin filaments and plasma membrane tension. The results showed that the actin filaments’ arrangement and FAs’ distribution in the patterned cells were changed significantly. The hypertonic solution resulted in the plasma membrane tension of the pattern cell changing more evenly and slowly in the zone rich in cytoskeletal filaments than in the zone lacking filaments. In addition, the membrane tension changed less in the adhesive area than in the non-adhesive area when destroying the cytoskeletal microfilaments. This suggested that patterned cells accumulated more actin filaments in the zone where FAs were difficult to generate to maintain the stability of the overall membrane tension. The actin filaments act as shock absorbers to cushion the alternation in membrane tension without changing the final value of membrane tension.
Open AccessVisualization of Cell Membrane Tension Regulated by the Microfilaments as a “Shock Absorber” in Micropatterned Cells
The extracellular stress signal transmits along the cell membrane–cytoskeleton–focal adhesions (FAs) complex, regulating the cell function through membrane tension. However, the mechanism of the complex regulating membrane tension is still unclear. This study designed polydimethylsiloxane stamps with specific shapes to change the actin filaments’ arrangement and FAs’ distribution artificially in live cells, visualized the membrane tension in real time, and introduced the concept of information entropy to describe the order degree of the actin filaments and plasma membrane tension. The results showed that the actin filaments’ arrangement and FAs’ distribution in the patterned cells were changed significantly. The hypertonic solution resulted in the plasma membrane tension of the pattern cell changing more evenly and slowly in the zone rich in cytoskeletal filaments than in the zone lacking filaments. In addition, the membrane tension changed less in the adhesive area than in the non-adhesive area when destroying the cytoskeletal microfilaments. This suggested that patterned cells accumulated more actin filaments in the zone where FAs were difficult to generate to maintain the stability of the overall membrane tension. The actin filaments act as shock absorbers to cushion the alternation in membrane tension without changing the final value of membrane tension.