OJOle Dan Jørgensen

Ole Dan Jørgensen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ole Dan Jørgensen has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Cost-effectiveness of an antibacterial envelope for infection prevention in patients undergoing cardiac resynchronization therapy reoperations in Denmark

    by Maria Hee Jung Park Frausing, Jens Brock Johansen, Daniela Afonso, Ole Dan Jørgensen, Thomas Olsen, Christian Gerdes, Mette Lundsby Johansen, Claudia Wolff, Stuart Mealing, Jens Cosedis Nielsen, et al.

    Use of an absorbable antibacterial envelope during implantation prevents cardiac implantable electronic device infections in patients with a moderate-to-high infection risk. Previous studies demonstrated that an envelope is cost-effective in high-risk patients within German, Italian, and English healthcare systems, but these analyses were based on limited data and may not be generalizable to other healthcare settings. A previously published decision-tree-based cost-effectiveness model was used to compare the costs per quality-adjusted life year (QALY) associated with adjunctive use of an antibacterial envelope for infection prevention compared to standard-of-care intravenous antibiotics. The model was adapted using data from a Danish observational two-centre cohort study that investigated infection-risk patients undergoing cardiac resynchronization therapy (CRT) reoperations with and without an antibacterial envelope (n = 1943). We assumed a cost-effectiveness threshold of €34 125/QALY gained, based on the upper threshold used by the National Institute for Health and Care Excellence (£30 000). An antibacterial envelope was associated with an incremental cost-effectiveness ratio (ICER) of €12 022 per QALY in patients undergoing CRT reoperations, thus indicating that the envelope is cost-effective when compared with standard of care. A separate analysis stratified by device type showed ICERS of €6227 (CRT defibrillator) and €29 177 (CRT pacemaker) per QALY gained. Cost-effectiveness ratios were favourable for patients undergoing CRT reoperations in the Danish healthcare system, and thus are in line with previous studies. Results from this study can contribute to making the technology available to Danish patients and align preventive efforts in the pacemaker and ICD area. CIED, cardiac implantable electronic device; CRT, cardiac resynchronization therapy (-P, pacemaker; -D, defibrillator); ICER, incremental cost-effectiveness ratio; HR, hazard ratio; IQR, interquartile range; QALY, quality-adjusted life year.


  • Open Access

    Risk factors for cardiac implantable electronic device infections: a nationwide Danish study

    by Thomas Olsen, Ole Dan Jørgensen, Jens Cosedis Nielsen, Anna Margrethe Thøgersen, Berit Thornvig Philbert, Maria Hee Jung Park Frausing, Niels Christian Foldager Sandgaard, Jens Brock Johansen

    Cardiac implantable electronic device (CIED) infection is a severe complication to modern management of cardiac arrhythmias. The CIED type and the type of surgery are recognized as risk factors for CIED infections, but knowledge of patient-related risk factors is scarce. This study aimed to identify lifelong patient-related risk factors for CIED infections. Consecutive Danish patients undergoing a CIED implantation or reoperation between January 1996 and April 2018 were included. The cohort consisted of 84 429 patients undergoing 108 494 CIED surgeries with a combined follow-up of 458 257 CIED-years. A total of 1556 CIED explantations were classified as either pocket (n = 1022) or systemic CIED infection (n = 534). Data were cross-linked with records from the Danish National Patient Registry and the Danish National Prescription Registry. Using multiple-record and multiple-event per subject proportional hazard analysis, specific patient-related risk factors were identified but with several variations amongst the subtypes of CIED infection. CIED reoperations were associated with the highest risk of pocket CIED infection but also CIED type, young age, and prior valvular surgery [hazard ratio (HR): 1.62, 95% confidence interval (CI): 1.29–2.04]. Severe renal insufficiency/dialysis (HR: 2.40, 95% CI: 1.65–3.49), dermatitis (HR: 2.80, 95% CI: 1.92–4.05), and prior valvular surgery (HR: 2.09, 95% CI: 1.59–2.75) were associated with the highest risk of systemic CIED infections. Congestive heart failure, ischaemic heart disease, malignancy, chronic obstructive pulmonary disease, and temporary pacing were not significant at multivariate analysis. Specific comorbidities and surgical procedures were associated with a higher risk of CIED infections but with variations amongst pocket and systemic CIED infection. Pocket CIED infections were associated with CIED reoperations, young age and more complex type of CIED, whereas systemic CIED infections were associated with risk factors predisposing to bacteraemia.


  • Open Access

    New onset anxiety and depression in patients with an implantable cardioverter defibrillator during 24 months of follow-up (data from the national DEFIB-WOMEN study)

    by Susanne S. Pedersen, Jens Cosedis Nielsen, Sonja Wehberg, Ole Dan Jørgensen, Sam Riahi, Jens Haarbo, Berit T. Philbert, Mogens Lytken Larsen, Jens Brock Johansen