Rafael Vieira Lantmann
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Rafael Vieira Lantmann has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Carlos Alexandre dos Santos
Materials Laboratory, School of Technology, Pontifical Catholic University of Rio Grande do Sul, Porto Alegre 90619-900, Brazil
2 shared publications - Tiago de Vasconcellos Pinheiro
School of Technology, Pontifcia Universidade Catlica do Rio Grande do Sul (PUCRS), Porto Alegre, Brazil
2 shared publications - André M. S. Mariante
School of Technology, Pontifical Catholic University of Rio Grande do Sul (PUCRS), 6681, Porto Alegre 90619-900, RS, Brazil
1 shared publication - Eleani Maria da Costa
Department of Materials Engineering, Pontificial Catholic University of Rio Grande do Sul, Porto Alegre 90619-900, Brazil
1 shared publication - Filipi Vianna
School of Technology, Pontifical Catholic University of Rio Grande do Sul
1 shared publication - Gabriel Cirilo da Silva Simioni
School of Technology, Pontifcia Universidade Catlica do Rio Grande do Sul (PUCRS), Porto Alegre, Brazil
1 shared publication
Latest Publications
- 19 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-9
Engineering Design Process in Developing a Pin-on-Disk Apparatus to Perform Dry or Lubricated Sliding Wear Test
The present work focuses on designing a pin-on-disc tribometer used to perform dry or lubricated wear tests according to the ASTM G99 standard method. The pin-on-disc device was developed using the engineering design process (EDP) based on steps related to problem understanding and solution construction stages. The tribometer is composed of an aluminum structure, a cylindrical test chamber, a disk rotation control system, load cells for measuring normal and tangential forces, a disk position sensor and temperature sensors. A 7” touch screen was selected for the user interface (HMI). Wear tests to verify the reliability and usefulness of the tribometer were carried out on disc-samples extracted from a hot-rolled AISI 1025 carbon-steel commercial bar, and performed with 2 and 10 N normal loads, linear sliding speeds of 0.27, 0.54, 0.82, 1.10 and 1.63 m/s, 500 m total sliding distance, using alumina ball as counterbody material. Dry and lubricated conditions were considered. Parameters as sliding distance, normal and frictional forces, and coefficient of friction were monitored during real-time tests. The procedure proved to be simple and safe. HMI enables the user to configure easily and quickly the test condition. A good agreement between the duplicate results was observed. During calibration, it was observed that the load cells and the servomotor presented standard deviations lower than 1.1 g and 0.2 rpm, respectively, and a percentage of uncertainty lower than 0.3. The LVDT showed a correlation regression coefficient of 0.999 between measured and output signals. During wear validation tests, all variations in results were less than 2% under the investigated conditions.
- 19 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-9
Engineering Design Process in Developing a Pin-on-Disk Apparatus to Perform Dry or Lubricated Sliding Wear Test
The present work focuses on designing a pin-on-disc tribometer used to perform dry or lubricated wear tests according to the ASTM G99 standard method. The pin-on-disc device was developed using the engineering design process (EDP) based on steps related to problem understanding and solution construction stages. The tribometer is composed of an aluminum structure, a cylindrical test chamber, a disk rotation control system, load cells for measuring normal and tangential forces, a disk position sensor and temperature sensors. A 7” touch screen was selected for the user interface (HMI). Wear tests to verify the reliability and usefulness of the tribometer were carried out on disc-samples extracted from a hot-rolled AISI 1025 carbon-steel commercial bar, and performed with 2 and 10 N normal loads, linear sliding speeds of 0.27, 0.54, 0.82, 1.10 and 1.63 m/s, 500 m total sliding distance, using alumina ball as counterbody material. Dry and lubricated conditions were considered. Parameters as sliding distance, normal and frictional forces, and coefficient of friction were monitored during real-time tests. The procedure proved to be simple and safe. HMI enables the user to configure easily and quickly the test condition. A good agreement between the duplicate results was observed. During calibration, it was observed that the load cells and the servomotor presented standard deviations lower than 1.1 g and 0.2 rpm, respectively, and a percentage of uncertainty lower than 0.3. The LVDT showed a correlation regression coefficient of 0.999 between measured and output signals. During wear validation tests, all variations in results were less than 2% under the investigated conditions.
- Open Access
Microstructure, Hardness, and Linear Reciprocating Sliding Wear Response of Directionally Solidified Al–(2.5, 3.5, 4.5)Cu–(0.25, 0.50)Cr Alloys
Aluminum alloys containing transition metal alloying elements have attracted interest from researchers. The effect of Cr additions of 0.25 and 0.50% on the thermal profile, microstructure, hardness, and linear reciprocating sliding wear response of as-cast hypoeutectic Al–Cu alloys with 2.5, 3.5, and 4.5% Cu (wt.%) was investigated. The binary Al–Cu and ternary Al–Cu–Cr alloys were directionally solidified under upward non-steady state heat transfer conditions using a dedicated solidification apparatus. Thermal analysis based on differential thermal analysis (DTA) and cooling curve profiles was performed to determine solidification thermal parameters such as Liquidus temperature (TL), transformation enthalpy (ΔH), and liquid cooling rate (ṪL). Samples extracted from the solidified ingots were submitted to optical microscopy, hardness measurement, and linear reciprocating sliding wear test using a high-frequency reciprocating rig (HFRR). The results showed a decrease at the beginning of solidification (TL) and of the transformation enthalpy (ΔH) when both alloy Cu and Cr contents increased, with a higher influence of Cu. The addition of Cu decreased cooling rates, whereas the increase in the alloy Cr concentration showed an opposite behavior, increasing cooling rates. The refinement of the primary dendrite arm spacing (λ1), as a consequence of the increase in alloying elements and solidification cooling rates, enhanced the hardness of the alloys, with the maximum value of 58 HB achieved in the ternary Al–4.5Cu–0.50Cr alloy. The wear tests indicated a better response to wear associated with microstructure refinement for the alloys with 2.5% Cu, for both Cr contents, an almost constant behavior for the 3.5% Cu alloys, and an opposite performance for the alloys with 4.5% Cu alloys that showed better wear resistance with coarsening of the λ1 and with the increase in the amount of the eutectic microconstituent.
Open AccessMicrostructure, Hardness, and Linear Reciprocating Sliding Wear Response of Directionally Solidified Al–(2.5, 3.5, 4.5)Cu–(0.25, 0.50)Cr Alloys
Aluminum alloys containing transition metal alloying elements have attracted interest from researchers. The effect of Cr additions of 0.25 and 0.50% on the thermal profile, microstructure, hardness, and linear reciprocating sliding wear response of as-cast hypoeutectic Al–Cu alloys with 2.5, 3.5, and 4.5% Cu (wt.%) was investigated. The binary Al–Cu and ternary Al–Cu–Cr alloys were directionally solidified under upward non-steady state heat transfer conditions using a dedicated solidification apparatus. Thermal analysis based on differential thermal analysis (DTA) and cooling curve profiles was performed to determine solidification thermal parameters such as Liquidus temperature (TL), transformation enthalpy (ΔH), and liquid cooling rate (ṪL). Samples extracted from the solidified ingots were submitted to optical microscopy, hardness measurement, and linear reciprocating sliding wear test using a high-frequency reciprocating rig (HFRR). The results showed a decrease at the beginning of solidification (TL) and of the transformation enthalpy (ΔH) when both alloy Cu and Cr contents increased, with a higher influence of Cu. The addition of Cu decreased cooling rates, whereas the increase in the alloy Cr concentration showed an opposite behavior, increasing cooling rates. The refinement of the primary dendrite arm spacing (λ1), as a consequence of the increase in alloying elements and solidification cooling rates, enhanced the hardness of the alloys, with the maximum value of 58 HB achieved in the ternary Al–4.5Cu–0.50Cr alloy. The wear tests indicated a better response to wear associated with microstructure refinement for the alloys with 2.5% Cu, for both Cr contents, an almost constant behavior for the 3.5% Cu alloys, and an opposite performance for the alloys with 4.5% Cu alloys that showed better wear resistance with coarsening of the λ1 and with the increase in the amount of the eutectic microconstituent.