Chrit T.W. Moonen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Chrit T.W. Moonen has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
Baudoin Denis de Senneville
Laboratory for Molecular and Functional Imaging: From Physiology to Therapy, CNRS/Université Victor Segalen Bordeaux 2, Bordeaux, France
1 shared publication- Bruno Quesson
CHU Bordeaux, IHU Lyric, Université de Bordeaux, Bordeaux, France
1 shared publication Charles Mougenot
Laboratory for Molecular and Functional Imaging, ERT CNRS/Université Victor Segalen, F-33076 Bordeaux, France
1 shared publicationClaudia Weidensteiner
Laboratory for Molecular and Functional Imaging: From Physiology to Therapy, CNRS/Université Victor Segalen Bordeaux 2, Bordeaux, France
1 shared publicationHervé Trillaud
Laboratory for Molecular and Functional Imaging: From Physiology to Therapy, CNRS/Université Victor Segalen Bordeaux 2, Bordeaux, France
1 shared publicationJean Palussière
Institut Bergonié, F‐33000 Bordeaux, France
1 shared publication
Latest Publications
- Open Access
- 26 October 2004
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 52 (5) , 1005-1015
Automatic spatial and temporal temperature control for MR‐guided focused ultrasound using fast 3D MR thermometry and multispiral trajectory of the focal point
Of the different modalities to induce local hyperthermia, focused ultrasound is the only noninvasive technology available at the moment. In addition to the 3D localization of the target region, it has been shown that MRI can provide real‐time thermometry and allows online, automatic control of temperature evolution of the focal point. Treatment of a large tissue volume (as compared to the focal spot size, i.e., the ultrasound wavelength) can be achieved rapidly by moving the focal point along an inside‐out spiral trajectory. It has been shown previously that under linear conditions of energy deposition versus temperature, the spatial profile of the temperature within a large area can be controlled. In this study, a proportional, integral, and derivative (PID) spatial‐and‐temporal controller is described for the control of the temperature evolution within the target region under more variable conditions. The aim was to reach a predefined temperature profile after a few successive trajectories. Heat conduction in tissue is exploited to obtain a uniform temperature increase in a volume using discrete sonications without any waiting time. Input data sets consisted of 3D temperature maps provided online by a MR scanner. For each new trajectory, the controller recalculates the number of sonications per surface unit (spatial density of points describing the trajectory) and the applied power. Its performance was tested ex vivo and in vivo. Diameters of the target region ranged from 9 mm to 19 mm. Targeted temperature increase ranged from +8°C to +18°C. Spatiotemporal temperature control showed good stability and fast convergence, for both circular and elliptic ROIs. Magn Reson Med 52:1005–1015, 2004.
- 26 October 2004
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 52 (5) , 1005-1015
Open AccessAutomatic spatial and temporal temperature control for MR‐guided focused ultrasound using fast 3D MR thermometry and multispiral trajectory of the focal point
Of the different modalities to induce local hyperthermia, focused ultrasound is the only noninvasive technology available at the moment. In addition to the 3D localization of the target region, it has been shown that MRI can provide real‐time thermometry and allows online, automatic control of temperature evolution of the focal point. Treatment of a large tissue volume (as compared to the focal spot size, i.e., the ultrasound wavelength) can be achieved rapidly by moving the focal point along an inside‐out spiral trajectory. It has been shown previously that under linear conditions of energy deposition versus temperature, the spatial profile of the temperature within a large area can be controlled. In this study, a proportional, integral, and derivative (PID) spatial‐and‐temporal controller is described for the control of the temperature evolution within the target region under more variable conditions. The aim was to reach a predefined temperature profile after a few successive trajectories. Heat conduction in tissue is exploited to obtain a uniform temperature increase in a volume using discrete sonications without any waiting time. Input data sets consisted of 3D temperature maps provided online by a MR scanner. For each new trajectory, the controller recalculates the number of sonications per surface unit (spatial density of points describing the trajectory) and the applied power. Its performance was tested ex vivo and in vivo. Diameters of the target region ranged from 9 mm to 19 mm. Targeted temperature increase ranged from +8°C to +18°C. Spatiotemporal temperature control showed good stability and fast convergence, for both circular and elliptic ROIs. Magn Reson Med 52:1005–1015, 2004.
- Open Access
- 29 March 2004
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 19 (4) , 438-446
Stability of real‐time MR temperature mapping in healthy and diseased human liver
Purpose: To determine the stability and quality of MR temperature mapping using the proton resonance frequency (PRF) method in the liver of hepatic tumor patients.Materials and Methods: The standard deviation (SD) of a series of temperature maps was determined in 30 patients (21 patients with cirrhotic livers with carcinoma, and nine patients with noncirrhotic livers with metastasis or angioma) and in five volunteers at normal body temperature under free breathing. A respiratory‐gated segmented echo‐planar imaging (EPI) sequence (three slices in one expiration phase) was performed with sensitivity encoding (SENSE) acceleration on a 1.5 T scanner. Motion‐corrupted images were identified by calculation of the cross‐correlation coefficient, and discarded.Results: A T2* range of 10–33 msec was found, with especially low values in advanced cirrhotic livers. The mean temperature SD in patients was 2.3°C (range = 1.5–5.0°C). The stability in healthy livers was slightly better than that in cirrhotic livers, and it was higher in the right liver than in the left liver. The gating failed in 4% of the images when the respiratory cycle was irregular, leading to motion artifacts and errors in the temperature maps.Conclusion: The achieved temperature stability and image quality makes real‐time quantitative monitoring of thermal ablation of liver tumors feasible on a clinical scanner. J. Magn. Reson. Imaging 2004;19:438–446.
- 29 March 2004
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 19 (4) , 438-446
Open AccessStability of real‐time MR temperature mapping in healthy and diseased human liver
Purpose: To determine the stability and quality of MR temperature mapping using the proton resonance frequency (PRF) method in the liver of hepatic tumor patients.Materials and Methods: The standard deviation (SD) of a series of temperature maps was determined in 30 patients (21 patients with cirrhotic livers with carcinoma, and nine patients with noncirrhotic livers with metastasis or angioma) and in five volunteers at normal body temperature under free breathing. A respiratory‐gated segmented echo‐planar imaging (EPI) sequence (three slices in one expiration phase) was performed with sensitivity encoding (SENSE) acceleration on a 1.5 T scanner. Motion‐corrupted images were identified by calculation of the cross‐correlation coefficient, and discarded.Results: A T2* range of 10–33 msec was found, with especially low values in advanced cirrhotic livers. The mean temperature SD in patients was 2.3°C (range = 1.5–5.0°C). The stability in healthy livers was slightly better than that in cirrhotic livers, and it was higher in the right liver than in the left liver. The gating failed in 4% of the images when the respiratory cycle was irregular, leading to motion artifacts and errors in the temperature maps.Conclusion: The achieved temperature stability and image quality makes real‐time quantitative monitoring of thermal ablation of liver tumors feasible on a clinical scanner. J. Magn. Reson. Imaging 2004;19:438–446.