Thomas Bongers
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Thomas Bongers has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Andrew W. Dickinson
Department of Cellular Pathology, Blackpool Teaching Hospitals NHS Foundation Trust, Whinney Heys Road, Blackpool FY3 8NR, UK
2 shared publications - Danielle Bury
Biocel UK Ltd., Hull HU10 6TS, UK
2 shared publications - Francis Luke Martin
Biocel UK Ltd, Hull, UK; Department of Cellular Pathology, Blackpool Teaching Hospitals NHS Foundation Trust, Whinney Heys Road, Blackpool, UK
2 shared publications - Maneesh N. Singh
Biocel UK Ltd., Hull HU10 6TS, UK
2 shared publications - Tarek Saba
Department of Cellular Pathology, Blackpool Teaching Hospitals NHS Foundation Trust, Whinney Heys Road, Blackpool FY3 8NR, UK
2 shared publications - Camilo de Lelis Medeiros de Morais
Center for Education, Science and Technology of the Inhamuns Region, State University of Ceará, Tauá 63660-000, Brazil
1 shared publication
Latest Publications
- Open Access
- 26 October 2023
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 13 (11) , 1533
Point-of-Care Disease Screening in Primary Care Using Saliva: A Biospectroscopy Approach for Lung Cancer and Prostate Cancer
Saliva is a largely unexplored liquid biopsy that can be readily obtained noninvasively. Not dissimilar to blood plasma or serum, it contains a vast array of bioconstituents that may be associated with the absence or presence of a disease condition. Given its ease of access, the use of saliva is potentially ideal in a point-of-care screening or diagnostic test. Herein, we developed a swab “dip” test in saliva obtained from consenting patients participating in a lung cancer-screening programme being undertaken in north-west England. A total of 998 saliva samples (31 designated as lung-cancer positive and 17 as prostate-cancer positive) were taken in the order in which they entered the clinic (i.e., there was no selection of participants) during the course of this prospective screening programme. Samples (sterile Copan blue rayon swabs dipped in saliva) were analysed using attenuated total reflection Fourier-transform infrared (ATR-FTIR) spectroscopy. In addition to unsupervised classification on resultant infrared (IR) spectra using principal component analysis (PCA), a range of feature selection/extraction algorithms were tested. Following preprocessing, the data were split between training (70% of samples, 22 lung-cancer positive versus 664 other) and test (30% of samples, 9 lung-cancer positive versus 284 other) sets. The training set was used for model construction and the test set was used for validation. The best model was the PCA-quadratic discriminant analysis (QDA) algorithm. This PCA-QDA model was built using 8 PCs (90.4% of explained variance) and resulted in 93% accuracy for training and 91% for testing, with clinical sensitivity at 100% and specificity at 91%. Additionally, for prostate cancer patients amongst the male cohort (n = 585), following preprocessing, the data were split between training (70% of samples, 12 prostate-cancer positive versus 399 other) and test (30% of samples, 5 prostate-cancer positive versus 171 other) sets. A PCA-QDA model, again the best model, was built using 5 PCs (84.2% of explained variance) and resulted in 97% accuracy for training and 93% for testing, with clinical sensitivity at 100% and specificity at 92%. These results point to a powerful new approach towards the capability to screen large cohorts of individuals in primary care settings for underlying malignant disease.
- 26 October 2023
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 13 (11) , 1533
Open AccessPoint-of-Care Disease Screening in Primary Care Using Saliva: A Biospectroscopy Approach for Lung Cancer and Prostate Cancer
Saliva is a largely unexplored liquid biopsy that can be readily obtained noninvasively. Not dissimilar to blood plasma or serum, it contains a vast array of bioconstituents that may be associated with the absence or presence of a disease condition. Given its ease of access, the use of saliva is potentially ideal in a point-of-care screening or diagnostic test. Herein, we developed a swab “dip” test in saliva obtained from consenting patients participating in a lung cancer-screening programme being undertaken in north-west England. A total of 998 saliva samples (31 designated as lung-cancer positive and 17 as prostate-cancer positive) were taken in the order in which they entered the clinic (i.e., there was no selection of participants) during the course of this prospective screening programme. Samples (sterile Copan blue rayon swabs dipped in saliva) were analysed using attenuated total reflection Fourier-transform infrared (ATR-FTIR) spectroscopy. In addition to unsupervised classification on resultant infrared (IR) spectra using principal component analysis (PCA), a range of feature selection/extraction algorithms were tested. Following preprocessing, the data were split between training (70% of samples, 22 lung-cancer positive versus 664 other) and test (30% of samples, 9 lung-cancer positive versus 284 other) sets. The training set was used for model construction and the test set was used for validation. The best model was the PCA-quadratic discriminant analysis (QDA) algorithm. This PCA-QDA model was built using 8 PCs (90.4% of explained variance) and resulted in 93% accuracy for training and 91% for testing, with clinical sensitivity at 100% and specificity at 91%. Additionally, for prostate cancer patients amongst the male cohort (n = 585), following preprocessing, the data were split between training (70% of samples, 12 prostate-cancer positive versus 399 other) and test (30% of samples, 5 prostate-cancer positive versus 171 other) sets. A PCA-QDA model, again the best model, was built using 5 PCs (84.2% of explained variance) and resulted in 97% accuracy for training and 93% for testing, with clinical sensitivity at 100% and specificity at 92%. These results point to a powerful new approach towards the capability to screen large cohorts of individuals in primary care settings for underlying malignant disease.
- Open Access
- 25 June 2023
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 13 (7) , 1039
ATR-FTIR Spectroscopy with Chemometrics for Analysis of Saliva Samples Obtained in a Lung-Cancer-Screening Programme: Application of Swabs as a Paradigm for High Throughput in a Clinical Setting
There is an increasing need for inexpensive and rapid screening tests in point-of-care clinical oncology settings. Herein, we develop a swab “dip” test in saliva obtained from consenting patients participating in a lung-cancer-screening programme being undertaken in North West England. In a pilot study, a total of 211 saliva samples (n = 170 benign, 41 designated cancer-positive) were randomly taken during the course of this prospective lung-cancer-screening programme. The samples (sterile Copan blue rayon swabs dipped in saliva) were analysed using attenuated total reflection Fourier-transform infrared (ATR-FTIR) spectroscopy. An exploratory analysis using principal component analysis (PCA,) with or without linear discriminant analysis (LDA), was then undertaken. Three pairwise comparisons were undertaken including: (1) benign vs. cancer following swab analysis; (2) benign vs. cancer following swab analysis with the subtraction of dry swab spectra; and (3) benign vs. cancer following swab analysis with the subtraction of wet swab spectra. Consistent and remarkably similar patterns of clustering for the benign control vs. cancer categories, irrespective of whether the swab plus saliva sample was analysed or whether there was a subtraction of wet or dry swab spectra, was observed. In each case, MANOVA demonstrated that this segregation of categories is highly significant. A k-NN (using three nearest neighbours) machine-learning algorithm also showed that the specificity (90%) and sensitivity (75%) are consistent for each pairwise comparison. In detailed analyses, the swab as a substrate did not alter the level of spectral discrimination between benign control vs. cancer saliva samples. These results demonstrate a novel swab “dip” test using saliva as a biofluid that is highly applicable to be rolled out into a larger lung-cancer-screening programme.
- 25 June 2023
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 13 (7) , 1039
Open AccessATR-FTIR Spectroscopy with Chemometrics for Analysis of Saliva Samples Obtained in a Lung-Cancer-Screening Programme: Application of Swabs as a Paradigm for High Throughput in a Clinical Setting
There is an increasing need for inexpensive and rapid screening tests in point-of-care clinical oncology settings. Herein, we develop a swab “dip” test in saliva obtained from consenting patients participating in a lung-cancer-screening programme being undertaken in North West England. In a pilot study, a total of 211 saliva samples (n = 170 benign, 41 designated cancer-positive) were randomly taken during the course of this prospective lung-cancer-screening programme. The samples (sterile Copan blue rayon swabs dipped in saliva) were analysed using attenuated total reflection Fourier-transform infrared (ATR-FTIR) spectroscopy. An exploratory analysis using principal component analysis (PCA,) with or without linear discriminant analysis (LDA), was then undertaken. Three pairwise comparisons were undertaken including: (1) benign vs. cancer following swab analysis; (2) benign vs. cancer following swab analysis with the subtraction of dry swab spectra; and (3) benign vs. cancer following swab analysis with the subtraction of wet swab spectra. Consistent and remarkably similar patterns of clustering for the benign control vs. cancer categories, irrespective of whether the swab plus saliva sample was analysed or whether there was a subtraction of wet or dry swab spectra, was observed. In each case, MANOVA demonstrated that this segregation of categories is highly significant. A k-NN (using three nearest neighbours) machine-learning algorithm also showed that the specificity (90%) and sensitivity (75%) are consistent for each pairwise comparison. In detailed analyses, the swab as a substrate did not alter the level of spectral discrimination between benign control vs. cancer saliva samples. These results demonstrate a novel swab “dip” test using saliva as a biofluid that is highly applicable to be rolled out into a larger lung-cancer-screening programme.