Haifeng Peng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Haifeng Peng has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Li Jin
Academy for Advanced Interdisciplinary Research, North University of China, Taiyuan 030051, China
2 shared publications - Mengwei Li
Academy for Advanced Interdisciplinary Research, North University of China, Taiyuan 030051, China
2 shared publications - Jiuhui Tang
Academy for Advanced Interdisciplinary Research, North University of China, Taiyuan 030051, China
1 shared publication - Kunyang Xie
Academy for Advanced Interdisciplinary Research, North University of China, Taiyuan 030051, China
1 shared publication - Peng Yang
Academy for Advanced Interdisciplinary Research, North University of China, Taiyuan 030051, China
1 shared publication - Shangzhou Guo
Academy for Advanced Interdisciplinary Research, North University of China, Taiyuan 030051, China
1 shared publication
Latest Publications
- Open Access
Design, Analysis, and Implementation of the Subdivision Interpolation Technique for the Grating Interferometric Micro-Displacement Sensor
A high-resolution grating interferometric micro-displacement sensor utilizing the subdivision interpolation technique is proposed and experimentally demonstrated. As the interference laser intensity varies sinusoidally with displacement, subdivision interpolation is a promising technique to achieve micro-displacement detection with a high resolution and linearity. However, interpolation errors occur due to the phase imbalance, offset error, and amplitude mismatch between the orthogonal signals. To address these issues, a subdivision interpolation circuit, along with 90-degree phase-shifter and high-precision DC bias-voltage techniques, converts an analog sinusoidal signal into standard incremental digital signals. This novel methodology ensures that its performance is least affected by the nonidealities induced by fabrication and assembly errors. Detailed design, analysis, and experimentation studies have been conducted to validate the proposed methodology. The experimental results demonstrate that the micro-displacement sensor based on grating interferometry achieved a displacement resolution of less than 1.9 nm, an accuracy of 99.8%, and a subdivision interpolation factor of 208. This research provides a significant guide for achieving high-precision grating interferometric displacement measurements.
Open AccessDesign, Analysis, and Implementation of the Subdivision Interpolation Technique for the Grating Interferometric Micro-Displacement Sensor
A high-resolution grating interferometric micro-displacement sensor utilizing the subdivision interpolation technique is proposed and experimentally demonstrated. As the interference laser intensity varies sinusoidally with displacement, subdivision interpolation is a promising technique to achieve micro-displacement detection with a high resolution and linearity. However, interpolation errors occur due to the phase imbalance, offset error, and amplitude mismatch between the orthogonal signals. To address these issues, a subdivision interpolation circuit, along with 90-degree phase-shifter and high-precision DC bias-voltage techniques, converts an analog sinusoidal signal into standard incremental digital signals. This novel methodology ensures that its performance is least affected by the nonidealities induced by fabrication and assembly errors. Detailed design, analysis, and experimentation studies have been conducted to validate the proposed methodology. The experimental results demonstrate that the micro-displacement sensor based on grating interferometry achieved a displacement resolution of less than 1.9 nm, an accuracy of 99.8%, and a subdivision interpolation factor of 208. This research provides a significant guide for achieving high-precision grating interferometric displacement measurements.
- Open Access
- 25 June 2023
- Published by MDPI AG in Micromachines
- Vol. 14 (7) , 1301
Design and Demonstration of an In-Plane Micro-Optical-Electro-Mechanical-System Accelerometer Based on Talbot Effect of Dual-Layer Gratings
An ultrasensitive single-axis in-plane micro-optical-electro-mechanical-system (MOEMS) accelerometer based on the Talbot effect of dual-layer gratings is proposed. Based on the Talbot effect of gratings, the acceleration can be converted into the variation of diffraction intensity, thus changing the voltage signal of photodetectors. We investigated and optimized the design of the mechanical structure; the resonant frequency of the accelerometer is 1878.9 Hz and the mechanical sensitivity is 0.14 μm/g. And the optical grating parameters have also optimized with a period of 4 μm and a grating interval of 10 μm. The experimental results demonstrated that the in-plane MOEMS accelerometer with an optimal design achieved an acceleration sensitivity of 0.74 V/g (with better than 0.4% nonlinearity), a bias stability of 75 μg and an acceleration resolution of 2.0 mg, suggesting its potential applications in smartphones, automotive electronics, and structural health detection.
- 25 June 2023
- Published by MDPI AG in Micromachines
- Vol. 14 (7) , 1301
Open AccessDesign and Demonstration of an In-Plane Micro-Optical-Electro-Mechanical-System Accelerometer Based on Talbot Effect of Dual-Layer Gratings
An ultrasensitive single-axis in-plane micro-optical-electro-mechanical-system (MOEMS) accelerometer based on the Talbot effect of dual-layer gratings is proposed. Based on the Talbot effect of gratings, the acceleration can be converted into the variation of diffraction intensity, thus changing the voltage signal of photodetectors. We investigated and optimized the design of the mechanical structure; the resonant frequency of the accelerometer is 1878.9 Hz and the mechanical sensitivity is 0.14 μm/g. And the optical grating parameters have also optimized with a period of 4 μm and a grating interval of 10 μm. The experimental results demonstrated that the in-plane MOEMS accelerometer with an optimal design achieved an acceleration sensitivity of 0.74 V/g (with better than 0.4% nonlinearity), a bias stability of 75 μg and an acceleration resolution of 2.0 mg, suggesting its potential applications in smartphones, automotive electronics, and structural health detection.