JAJoseph Appelbaum

Joseph Appelbaum

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Joseph Appelbaum has a total of 4 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Analytical Modeling of Solar Radiation Distribution on Vertical PV Facades in Urban Settings

    by Joseph Appelbaum, Assaf Peled

    With the need for increasing energy demand due to population growth in cities, and advancements in the efficiency of semi-transparent photovoltaic (ST-PV) technology, the integration of ST-PV modules into building windows has become feasible. This manuscript presents a novel analytical methodology for estimating incident solar energy on vertical PV modules integrated into building facades in an urban environment, emphasizing shade caused by nearby buildings. Monthly and annual direct-beam, diffusion, and global energies are calculated for different wall heights, building separation, and orientation. In addition, the distribution of the incident energy along the height of the wall is evaluated, indicating a non-uniform distribution. The incident diffusion energy is compared between isotropic and anisotropic models. The anisotropic model predicts higher diffusion energy by 3.5% to 14.5%, depending on the building separation. The incident energy on building facades is calculated for locations at low-mid (32°6’ N) and at high-mid (52.2° N) latitudes. The results show, for example, that both the front side of a front-building wall and the front side of a rear-building wall receive the same amount of annual global energy—913 kWh/m2—for a separation of 25 m between the buildings. Decreasing the distance from 25 m to 10 m decreases the annual incident global energy on a rear-building wall by 15%.

  • Open Access

    Anisotropic Diffuse Radiation Model of Photovoltaic Systems Deployed near Walls

    by Joseph Appelbaum, Assaf Peled

    The deployment of solar photovoltaic (PV) systems on rooftops in urban environments is to reduce land area required for electricity generation. These deployments may encounter shading and masking on the PV collectors from surrounding building walls, thus reducing the generated electricity. The present article proposes a novel anisotropic diffuse radiation model and investigates the diffuse masking losses stemming from obscuring part of the visible sky to the PV collectors by front rows and by walls erected near the collectors. Monthly and annually collected energies of the anisotropic and the isotropic diffuse radiation models are compared for four different simulated configurations of PV systems deployed near walls. The proposed novel modified model uses the original Klucher (1979) analytical diffuse radiation model for comparing the energies. The anisotropic model predicts a diffuse energy between 4.5% and 13% higher than the isotropic model for a site with 30% diffuse radiation, and nearly 30% higher diffuse energy for a site with 50% diffuse radiation, depending on system configuration. Applying the proposed anisotropic model allows us to assess more accurately the contribution of the diffuse radiation to the generated electric energy of PV systems.

  • Open Access

    Anisotropic Diffuse Radiation Model of Photovoltaic Systems

    by Joseph Appelbaum, Assaf Peled

    The diffuse solar radiation is a component of the global solar radiation and may contribute a significant percentage (50% and above in some locations) of the electric output energy of Photovoltaic (PV) systems. Therefore, it is important to improve the diffuse radiation models to obtain accurate values of the incident diffuse radiation. Solar diffuse radiation models are based on isotropic and anisotropic models. The anisotropic models take into account also the circumsolar and horizon brightening. Both types of models are developed in the literature for single rows. As photovoltaic fields are deployed in multiple collector rows, the second and subsequent collector rows are partially obscured by the rows in front and thus, affecting the incident diffuse radiation on the collectors. The present article modifies an anisotropic model by two factors: (a) sky view factor of the second (and subsequent rows) collector row and (b) correction to circumsolar brightening (correction to horizon brightening in negligible, at the site of the study, and is not considered). The modified model is demonstrated on Klucher model for diffuse radiation. The study shows that the anisotropic model provides higher annual diffuse radiation by 20% than the isotropic model, higher incident global energies of about 5.5%, and the difference in the incident diffuse radiation for collectors with azimuth angles in range γ C = 0 0 $$ {\gamma}_C={0}^0 $$ to γ C = 30 0 $$ {\gamma}_C={30}^0 $$ , is negligible. The use of the modified anisotropic model allows to asses more accurately the contribution of the diffuse radiation to the generated electric energy.


  • Open Access

    PV Collectors on Building Walls in Urban Environment

    by Joseph Appelbaum, Assaf Peled

    Buildings located in highly urbanized areas have not been considered for photovoltaic (PV) deployment on building walls due to limitation of ground and rooftops space. As the need for increasing energy demand due to population growth in cities, and the advancements in the efficiency of semi-transparent (ST-PV) solar cell technology, the integration of ST-PV modules into building windows, become feasible. The present article proposes a novel methodology for calculating the incident solar energy on PV vertical modules deployed on building walls and windows facing the southern direction and obscured by a nearby building in front. The present work analyses analytically, for the first time, the incident energy and its distribution on PV vertical modules along a wall height. Monthly and annually direct beam, diffuse and global energies are calculated for different wall height, building separation and orientation. The results shows, for example, that both the front and rear building walls receive the same amount of annual direct beam energy 913 kWh/m2 for a distance 25 m between the buildings. Decreasing the distance from 25 m to 10 m, decreases the annual incident global energy on the rear-building wall by 15 %.

  • Open Access

    Anisotropic Diffuse Radiation of Photovoltaic Single‐Axis Tracking Collectors

    by Joseph Appelbaum, Assaf Peled

    Numerous articles in recent years indicate an interest in solar tracing technology, emphasizing the tracking mechanisms, sensor integration, and automation techniques to enhance solar energy efficiency. These articles demonstrate that solar tracking systems significantly increases the average yearly energy generation over fixed PV systems. However, these works do not consider anisotropic diffuse radiation to assess the incident solar radiation on PV solar tracking systems. Therefore, the purpose of the present study is to compare the incident diffuse energy of single‐axis tracking systems between isotropic and anisotropic diffuse radiation models to improve the assessed incident solar radiation on the PV systems. In addition, a new obscuring factor is introduced into the anisotropic model. The comparison is performed on north‐south horizontal axis: east‐west tracking and east‐west horizontal axis: north‐south tracking, both using astronomical tracking algorithm. The anisotropic diffuse radiation model predicts 7.68% higher annual diffuse energy and 2.02% higher annual global energy for east‐west tracking, and 12.32% higher annual diffuse energy and 2.81% higher annual global energy for north‐south tracking, than the isotropic model. The study pertains to Tel Aviv area, latitude ϕ = 32 ° 6 ′ N , longitude 34 ° 51 ′ E , and relatively low percentage of diffuse radiation of about 30%.

  • Open Access

    Shadow Analysis of Photovoltaic Systems Deployed Near Obscuring Walls

    by Joseph Appelbaum, Assaf Peled, Avi Aronescu

    As photovoltaic (PV) deployment has expanded from rural sites to the built environment, rooftops are increasingly used for electricity generation. In these settings, the visible sky is often partially obstructed by adjacent walls, producing shading that reduces energy yield. This study quantifies the effect of wall shading on incident solar radiation and system losses, and contrasts it with inter-row (mutual) shading experienced by PV arrays in open fields. Systems installed near obscuring walls are subject to both phenomena. To our knowledge, the specific impact of wall shading on PV systems has not been examined comprehensively. We characterize how wall height governs shadow geometry, determine the resulting numbers of shaded and unshaded cells and modules, and assess how shaded modules influence the performance of the remaining modules in a series string. For the parameter set analyzed, annual energy losses are 7.7% due to wall shading and 4% due to inter-row shading, yielding a combined loss of 10.2%. The methods and results provide a practical basis for designers to estimate shading losses and expected energy production for PV systems sited near obscuring walls.


  • Open Access

    Solar Radiation on Photovoltaic Systems Deployed near Obscuring Walls

    by Joseph Appelbaum, Assaf Peled

    The deployment of solar photovoltaic (PV) systems on rooftops in urban environments utilizes the rooftop areas for electricity generation. Rooftops may provide a large amount of empty space that can reduce the use of land for large PV plant installations and other purposes. These deployments may encounter shading on the PV collectors from surrounding building walls, thus reducing the incident direct beam radiation on the PV collectors, resulting in shading losses. Moreover, walls and collector rows block part of the visible sky, reducing the incident diffuse radiation on the collectors, resulting in masking losses. The present study complements previous studies by the authors (see the references) by calculating the incident beam, diffuse and global radiation, and their distribution across the collector rows for four configurations of PV systems installed near obscuring walls. In addition, the article quantifies the shading problem by simulating the shading dimensions and their patterns caused by walls and collector rows. The article is of practical importance for designers of PV systems in urban environments. The simulation results indicate an almost uniform distribution of the incident radiation between the collector rows. On the other hand, the losses may reach 8 percent for a wall height of 4 m for the parameters used in the study.


  • Open Access

    The Effect of Walls on the Sky View Factors of Photovoltaic Systems

    by Joseph Appelbaum, Assaf Peled

    Photovoltaic collectors deployed in multiple rows and near the structure’s walls are obscured from the receiving part of the diffuse skylight. Obscuring part of the diffuse skylight to the collectors decreases the incident diffuse radiation and thus, results in diffuse radiation losses. These losses are associated with the sky view factors. The inter-row diffuse radiation losses are associated with the sky view factor of the collector, and the wall diffuse radiation losses are associated with the sky view factor caused by the wall. The purpose of the present study is to develop mathematical expressions and a methodology for sky view factors of PV systems installed near obscuring walls. The study investigates the effect of the wall height, distance of the wall to the collectors, and collector and wall azimuth angles, on the sky view factors. The study may assist the PV system designer in assessing the contribution of the incident diffuse radiation to the generated electric energy of PV systems installed near obscuring walls. The simulation results indicate that the overall range of the sky view factor variation may be quite noticeable, between 0.97 (without the presence of a wall) and 0.78 (with the presence of a wall), for the parameters used in the study.


  • Open Access

    Wall Shading Losses of Photovoltaic Systems

    by Joseph Appelbaum, Assaf Peled, Avi Aronescu

    The deployment of photovoltaic (PV) systems on rooftops in urban environments may encounter shading on the PV collectors from surrounding walls, acting adversely on the generated electricity of the PV systems. Most studies on the shading of PV systems do not deal analytically with the shading losses of PV collectors affected by walls, fences, and obscuring objects. The present article mathematically formulates shadow expressions for wall and inter-row shading on PV collectors and calculates the percentage of annual shading losses affected by wall heights and azimuth angles, the distances of walls to collectors, and the length and azimuth angles of collectors. This study indicates that the shading losses increase for shorter distances from the collector to the walls and for higher walls. Shading losses may reach 7 percent for wall heights of 4 m and at a distance of 2 m from the collectors to a wall. The results indicate that wall shading dominates inter-row shading.


  • Open Access

    The Effect of Collector Azimuth on Inter-Row Shading in Photovoltaic Fields—A Comprehensive Point of View

    by Avi Aronescu, Joseph Appelbaum

    Rooftop buildings, mountain terrains, rivers, and lake beds may be oriented at different azimuths other than due south (in the northern hemisphere), on which photovoltaic (PV) systems may be installed. The present study presents a comprehensive point of view on the relation between the inter-row spacing and the inter-row shading in multiple-row collectors of PV fields; it analytically formulates the inter-row spacing and the associated shading losses for collectors deployed at any azimuth on horizontal, sloped-planed, and oriented toward the south and north, and is supported by the numerical results. Several criteria for the inter-row spacing are applied in the study; among them is a newly introduced criterion appropriate for the collectors deployed at a given azimuth. This study indicates that shorter spacing results in increased shading; minimum shading is obtained for collectors oriented toward the equator; inter-row spacing for maintenance purposes is used in limited dimensions of the PV fields and, usually, in optimal PV system designs; less shading occurs for systems deployed on sloped planes oriented toward the south; less shading is obtained for collectors based on the new criterion, where collectors are deployed at azimuth equal to the solar azimuth, and larger spacing is required for collectors deployed on northern slopes.