Max Schoenen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Max Schoenen has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Ioana Slabu
Institute of Applied Medical Engineering, Helmholtz Institute, Medical Faculty, RWTH Aachen University, 52074 Aachen, Germany
3 shared publications Anna Klassen
Chair of Bioseparation Engineering, TUM School of Engineering and Design, Technical University of Munich, Boltzmannstraße 15, 85748 Garching, Germany
1 shared publication- Benedict Bauer
Institut für Textiltechnik, RWTH Aachen University, 52074 Aachen, Germany
1 shared publication - Caroline Emonts
Institut für Textiltechnik, RWTH Aachen University, 52074 Aachen, Germany
1 shared publication - Chiara Turrina
Chair of Bioseparation Engineering, School of Engineering and Design, Technical University of Munich, Boltzmannstr. 15, 85748 Garching, Germany
1 shared publication - Davide Milani
Chair of Bioseparation Engineering, TUM School of Engineering and Design, Technical University of Munich, Boltzmannstraße 15, 85748 Garching, Germany
1 shared publication
Latest Publications
- Open Access
- 23 September 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (19) , 195002
Linear magnetic nanoparticle structures as key feature in magnetic particle imaging
Objective. Magnetic particle imaging (MPI) opens huge possibilities in image-guided therapy. Its effectiveness is strongly influenced by the quality of the magnetic nanoparticles (MNP) used as tracers. Besides MNP optimisation following different synthesis routes, MNP assembly into linear structures can significantly enhance their performance in MPI. The present study investigates the influence of linear MNP structures on MPI signal for different MNP types. With regard to theranostic applications the role of linear structures in hybrid stent imaging is explored. Approach. Three MNP types were used to create linear MNP structures. MNP respectively the MNP structures were immobilised in a hydrogel and positioned at various orientations relative to the coordinate system of the MPI. A multi-channel reconstruction approach was applied to assess the orientation-specific signal. The insights gained were used to reconstruct a fibre-based polymer stent with incorporated linear structures. Main results. Different linear structure orientations could be delineated and visualised in multi-colour images. Linear structures orientated parallel to the direction of a magnetic excitation field lead to the highest signal intensities and peak positions of MPI frequency spectra were located near multiples of the frequency of the excitation coil. Image reconstructions of the stent were very sensitive to the orientation of linear structures within the fibres. Significance. This study reveals that the assembly of MNP results in non-linear contributions to the MPI signal. Consequently, the MPI signal intensity is not as usual merely linearly correlated with MNP concentration increasing the complexity in image reconstruction. The findings demonstrate the necessity of accounting for MNP structure orientation in image reconstruction. They also reveal the high potential of MPI to detect different MNP types and structures. Linear structures cause either significant signal reduction or signal increase depending on the angular position of the linear structures relative to the direction of MPI magnetic fields.
- 23 September 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (19) , 195002
Open AccessLinear magnetic nanoparticle structures as key feature in magnetic particle imaging
Objective. Magnetic particle imaging (MPI) opens huge possibilities in image-guided therapy. Its effectiveness is strongly influenced by the quality of the magnetic nanoparticles (MNP) used as tracers. Besides MNP optimisation following different synthesis routes, MNP assembly into linear structures can significantly enhance their performance in MPI. The present study investigates the influence of linear MNP structures on MPI signal for different MNP types. With regard to theranostic applications the role of linear structures in hybrid stent imaging is explored. Approach. Three MNP types were used to create linear MNP structures. MNP respectively the MNP structures were immobilised in a hydrogel and positioned at various orientations relative to the coordinate system of the MPI. A multi-channel reconstruction approach was applied to assess the orientation-specific signal. The insights gained were used to reconstruct a fibre-based polymer stent with incorporated linear structures. Main results. Different linear structure orientations could be delineated and visualised in multi-colour images. Linear structures orientated parallel to the direction of a magnetic excitation field lead to the highest signal intensities and peak positions of MPI frequency spectra were located near multiples of the frequency of the excitation coil. Image reconstructions of the stent were very sensitive to the orientation of linear structures within the fibres. Significance. This study reveals that the assembly of MNP results in non-linear contributions to the MPI signal. Consequently, the MPI signal intensity is not as usual merely linearly correlated with MNP concentration increasing the complexity in image reconstruction. The findings demonstrate the necessity of accounting for MNP structure orientation in image reconstruction. They also reveal the high potential of MPI to detect different MNP types and structures. Linear structures cause either significant signal reduction or signal increase depending on the angular position of the linear structures relative to the direction of MPI magnetic fields.
- Open Access
- 11 April 2025
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 267, 108775
Assessing the impact of magnetic nanoparticle assemblies on magnetic hyperthermia performance: A predictive study
- 11 April 2025
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 267, 108775
Open AccessAssessing the impact of magnetic nanoparticle assemblies on magnetic hyperthermia performance: A predictive study
- Open Access
- 23 July 2024
- Published by Royal Society of Chemistry (RSC) in Nanoscale Advances
- Vol. 6 (17) , 4352-4359
Improving MPI and hyperthermia performance of superparamagnetic iron oxide nanoparticles through fractional factorial design of experiments
Superparamagnetic iron oxide nanoparticles (SPIONs) are widely used for biomedical applications, including magnetic particle imaging (MPI) and magnetic hyperthermia. The co-precipitation method is one of the most common synthetic routes to obtain SPIONs, since it is simple and does not require extreme conditions, such as high temperatures. Despite its prevalence, however, the co-precipitation synthesis presents some challenges, most notably the high batch-to-batch variability, as multiple factors can influence nanoparticle growth. In this study, we utilized a fractional factorial design of experiments to identify key factors influencing SPION growth, properties, and performance in MPI and magnetic hyperthermia, namely Fe3+ content, pH, temperature, stirring, and atmosphere. Notably, our study unveiled secondary interactions, particularly between temperature and Fe3+ content, as well as pH and Fe3+ content, for which simultaneous changes of both parameters promoted greater effects than the sum of each factor effect alone, emphasizing the impact of synergistic effects on SPION growth and performance. These findings provide a deeper understanding of the growth mechanism of SPIONs, reconcile discrepancies in the existing literature, and underscore the importance of characterizing secondary interactions to improve the performance of SPIONs for biomedical applications.
- 23 July 2024
- Published by Royal Society of Chemistry (RSC) in Nanoscale Advances
- Vol. 6 (17) , 4352-4359
Open AccessImproving MPI and hyperthermia performance of superparamagnetic iron oxide nanoparticles through fractional factorial design of experiments
Superparamagnetic iron oxide nanoparticles (SPIONs) are widely used for biomedical applications, including magnetic particle imaging (MPI) and magnetic hyperthermia. The co-precipitation method is one of the most common synthetic routes to obtain SPIONs, since it is simple and does not require extreme conditions, such as high temperatures. Despite its prevalence, however, the co-precipitation synthesis presents some challenges, most notably the high batch-to-batch variability, as multiple factors can influence nanoparticle growth. In this study, we utilized a fractional factorial design of experiments to identify key factors influencing SPION growth, properties, and performance in MPI and magnetic hyperthermia, namely Fe3+ content, pH, temperature, stirring, and atmosphere. Notably, our study unveiled secondary interactions, particularly between temperature and Fe3+ content, as well as pH and Fe3+ content, for which simultaneous changes of both parameters promoted greater effects than the sum of each factor effect alone, emphasizing the impact of synergistic effects on SPION growth and performance. These findings provide a deeper understanding of the growth mechanism of SPIONs, reconcile discrepancies in the existing literature, and underscore the importance of characterizing secondary interactions to improve the performance of SPIONs for biomedical applications.
- Open Access
- 24 June 2023
- Published by Elsevier in Colloids and Surfaces B: Biointerfaces
- Vol. 228, 113428
Application of magnetic iron oxide nanoparticles: Thrombotic activity, imaging and cytocompatibility of silica-coated and carboxymethyl dextrane-coated particles
- 24 June 2023
- Published by Elsevier in Colloids and Surfaces B: Biointerfaces
- Vol. 228, 113428
Open AccessApplication of magnetic iron oxide nanoparticles: Thrombotic activity, imaging and cytocompatibility of silica-coated and carboxymethyl dextrane-coated particles