Theodoros Papingiotis
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Theodoros Papingiotis has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Irene P. Koronaki
School of Mechanical Engineering, National Technical University of Athens, 15780 Athens, Greece
4 shared publications - Christos Tzivanidis
Department of Thermal Engineering, National Technical University of Athens, 15772 Athens, Greece
3 shared publications - Dimitrios N. Korres
School of Mechanical Engineering, National Technical University of Athens, 157 80 Athens, Greece
3 shared publications - George-Rafael Domenikos
Early Mental Potential & Wellbeing Research (EMPOWER) Centre, Nanyang Technological University, Singapore 308232, Singapore
1 shared publication - Panagiotis Bitsikas
Laboratory of Applied Thermodynamics, Mechanical Engineering School, National Technical University of Athens, Heroon Polytecheiou 9, 15780 Zografou, Athens, Greece
1 shared publication
Latest Publications
- Open Access
Utilization of H2O/CuO and Syltherm 800/CuO Nanofluids in a Concentrating Solar Collector with Photovoltaic Elements
This study examined the performance of a concentrating solar collector with an asymmetric reflector. Two receivers were investigated, differing in the presence of photovoltaic cells. The first one was equipped with cells on both sides while the other was without cells. The analysis was performed using a numerical model that integrates a combination of three-dimensional optical and thermal analyses developed in COMSOL. The investigation included studying the influence of CuO/water and CuO/Syltherm 800 nanofluids on the thermal performance for the receiver without photovoltaic elements, as well as on both thermal and electrical efficiencies for the hybrid receiver. Two volumetric concentrations of CuO in water and Syltherm 800, 3% and 5%, were explored with varying inlet temperatures, ranging from 20 °C to 80 °C for the hybrid solar unit and from 20 °C to 140 °C for the thermal solar unit. The outcomes of the examination were compared between the nanofluids and the pure base fluid. Properly pressurized water was considered in the case without photovoltaic elements.
Open AccessUtilization of H2O/CuO and Syltherm 800/CuO Nanofluids in a Concentrating Solar Collector with Photovoltaic Elements
This study examined the performance of a concentrating solar collector with an asymmetric reflector. Two receivers were investigated, differing in the presence of photovoltaic cells. The first one was equipped with cells on both sides while the other was without cells. The analysis was performed using a numerical model that integrates a combination of three-dimensional optical and thermal analyses developed in COMSOL. The investigation included studying the influence of CuO/water and CuO/Syltherm 800 nanofluids on the thermal performance for the receiver without photovoltaic elements, as well as on both thermal and electrical efficiencies for the hybrid receiver. Two volumetric concentrations of CuO in water and Syltherm 800, 3% and 5%, were explored with varying inlet temperatures, ranging from 20 °C to 80 °C for the hybrid solar unit and from 20 °C to 140 °C for the thermal solar unit. The outcomes of the examination were compared between the nanofluids and the pure base fluid. Properly pressurized water was considered in the case without photovoltaic elements.
- Open Access
- 25 September 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (19) , 10669
Energetical and Exergetical Analyses of a Concentrating PV/T Collector: A Numerical Approach
The specific work presents an optical and thermal investigation of a hybrid thermo-photovoltaic solar collector with an asymmetrical compound parabolic mirror. Such collectors offer an innovative and sustainable approach to address both the thermal and electrical demands of residents on islands using renewable sources of energy and thus reducing the dependency on fossil fuels. The main goal of this investigation involves an analysis of the prementioned type of solar collector, incorporating an innovative and cost-effective numerical modelling technique aiming to enhance comprehension of its energy and exergy performance. The optical performance of the collector was calculated first with ray tracing for the month of June, and the ideal slope was determined for the same month. After the optical analysis, the energy and exergy performance were both estimated by implementing a novel numerical method in both COMSOL and SolidWorks. Based on the optical analysis, it was determined that the most favorable inclination angle for achieving optimum optical efficiency on the mean day of June is 10°. The thermal analysis, focusing on thermal efficiency, showed a maximum deviation of 5.3% between the two solutions, which indicates the reliability of the method. The collector achieved a maximum thermal efficiency of 58.55% and a maximum exergy efficiency of 16.94%.
- 25 September 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (19) , 10669
Open AccessEnergetical and Exergetical Analyses of a Concentrating PV/T Collector: A Numerical Approach
The specific work presents an optical and thermal investigation of a hybrid thermo-photovoltaic solar collector with an asymmetrical compound parabolic mirror. Such collectors offer an innovative and sustainable approach to address both the thermal and electrical demands of residents on islands using renewable sources of energy and thus reducing the dependency on fossil fuels. The main goal of this investigation involves an analysis of the prementioned type of solar collector, incorporating an innovative and cost-effective numerical modelling technique aiming to enhance comprehension of its energy and exergy performance. The optical performance of the collector was calculated first with ray tracing for the month of June, and the ideal slope was determined for the same month. After the optical analysis, the energy and exergy performance were both estimated by implementing a novel numerical method in both COMSOL and SolidWorks. Based on the optical analysis, it was determined that the most favorable inclination angle for achieving optimum optical efficiency on the mean day of June is 10°. The thermal analysis, focusing on thermal efficiency, showed a maximum deviation of 5.3% between the two solutions, which indicates the reliability of the method. The collector achieved a maximum thermal efficiency of 58.55% and a maximum exergy efficiency of 16.94%.
- Open Access
Parametric Numerical Analysis of β-Type Stirling Engine
This paper presents a parametric analysis of a -type Stirling engine, focusing on the impact of various rotational speeds. The investigation employs a three-dimensional computational fluid analysis model. The study places emphasis on monitoring and understanding the temperature variations across the primary components of the engine, including the regenerator, heater, and cooler. The full apparatus is designed and simulated, acquiring the results for its energy output and thermal behavior.Using this CFD model, parameterization optimization is presented, aiming to establish the best conditions for the engine and regenerator efficiencies. Utilizing the results of the behavior of the machine, a correlation between the Nusselt and Reynolds numbers with regard to the rotational speeds is produced, giving a further understanding of the conduct of the working medium in the system.Open AccessParametric Numerical Analysis of β-Type Stirling Engine
This paper presents a parametric analysis of a -type Stirling engine, focusing on the impact of various rotational speeds. The investigation employs a three-dimensional computational fluid analysis model. The study places emphasis on monitoring and understanding the temperature variations across the primary components of the engine, including the regenerator, heater, and cooler. The full apparatus is designed and simulated, acquiring the results for its energy output and thermal behavior.Using this CFD model, parameterization optimization is presented, aiming to establish the best conditions for the engine and regenerator efficiencies. Utilizing the results of the behavior of the machine, a correlation between the Nusselt and Reynolds numbers with regard to the rotational speeds is produced, giving a further understanding of the conduct of the working medium in the system. - Open Access
- 21 June 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (13) , 9932
Thermal and Optical Analyses of a Hybrid Solar Photovoltaic/Thermal (PV/T) Collector with Asymmetric Reflector: Numerical Modeling and Validation with Experimental Results
This study presents a combined thermal and optical, three-dimensional analysis of an asymmetric compound parabolic collector (ACPC) with an integrated hybrid photovoltaic/thermal (PV/T) receiver with the aim of establishing a sustainable approach in two ways: firstly, by determining the optimal tilt angle for operations, and secondly, by introducing an innovative simulation method which reduces computational cost while calculating thermal performance. Initially the Incident Angle Modifier () was calculated for a wide range of incident angles, and the ray-tracing results were verified using three different simulation tools (Tonatiuh, COMSOL, and SolidWorks) with mean deviations being lower than 4%. The optimal tilt angle of the collector was determined for seven months of the year by conducting a detailed ray-tracing analysis for the mean day of each month considering whole day operation. In the thermal analysis part, the authors introduced novel numerical modeling for numerical simulations. This modeling method, designed with sustainability in mind, enables lighter computational domains for the air gap while achieving accurate numerical results. The approach was established using two distinct simulation tools: COMSOL and SolidWorks. From the optical analysis, it was found that in all months examined there is a four-hour time range around solar noon in which the optimum tilt angle remains constant at a value of 30°. The numerical models constructed for the thermal analysis were verified with each other (6.15% mean deviation) and validated through experimental results taken from the literature regarding the examined collector (<6% mean deviation). In addition, the two simulation tools exhibited a deviation of around 6% between each other. Finally, the thermal performance of the collector was investigated for the mean day of September at solar noon by adopting the optimal tilt angle for that month according to the optical analysis, considering inlet temperatures from 20 °C up to 80 °C.- 21 June 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (13) , 9932
Open AccessThermal and Optical Analyses of a Hybrid Solar Photovoltaic/Thermal (PV/T) Collector with Asymmetric Reflector: Numerical Modeling and Validation with Experimental Results
This study presents a combined thermal and optical, three-dimensional analysis of an asymmetric compound parabolic collector (ACPC) with an integrated hybrid photovoltaic/thermal (PV/T) receiver with the aim of establishing a sustainable approach in two ways: firstly, by determining the optimal tilt angle for operations, and secondly, by introducing an innovative simulation method which reduces computational cost while calculating thermal performance. Initially the Incident Angle Modifier () was calculated for a wide range of incident angles, and the ray-tracing results were verified using three different simulation tools (Tonatiuh, COMSOL, and SolidWorks) with mean deviations being lower than 4%. The optimal tilt angle of the collector was determined for seven months of the year by conducting a detailed ray-tracing analysis for the mean day of each month considering whole day operation. In the thermal analysis part, the authors introduced novel numerical modeling for numerical simulations. This modeling method, designed with sustainability in mind, enables lighter computational domains for the air gap while achieving accurate numerical results. The approach was established using two distinct simulation tools: COMSOL and SolidWorks. From the optical analysis, it was found that in all months examined there is a four-hour time range around solar noon in which the optimum tilt angle remains constant at a value of 30°. The numerical models constructed for the thermal analysis were verified with each other (6.15% mean deviation) and validated through experimental results taken from the literature regarding the examined collector (<6% mean deviation). In addition, the two simulation tools exhibited a deviation of around 6% between each other. Finally, the thermal performance of the collector was investigated for the mean day of September at solar noon by adopting the optimal tilt angle for that month according to the optical analysis, considering inlet temperatures from 20 °C up to 80 °C.