Naoki Kinoshita
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Naoki Kinoshita has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Akira Makino
Biomedical Imaging Research Center, University of Fukui
1 shared publication Chie Kurokawa
Department of Radiological Technology, Faculty of Health Science, Juntendo University, Tokyo, Japan
1 shared publication- Hidehiko Okazawa
Life Science Innovation Center, School of Medical Sciences, University of Fukui, Fukui, Japan
1 shared publication Hiroshi Oguchi
Radiological Technology Department, Iida Municipal Hospital, Iida, Japan
1 shared publication- Hiroyuki Maeda
Department of Gastrointestinal and Breast Surgery, University of Fukui, 23-3 Matsuokashimoaizuki, Eiheiji-cho, Yoshida-gun, Fukui 910-1193, Japan
1 shared publication Kana Motegi
Section of Radiation Safety and Quality Assurance, National Cancer Center Hospital East, Kashiwa, Japan
1 shared publication
Latest Publications
- Open Access
- 14 November 2024
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 18 (1) , 58-77
Quantification of uncertainties in reference and relative dose measurements, dose calculations, and patient setup in modern external beam radiotherapy
Uncertainties in the steps of external beam radiotherapy (EBRT) affect patient outcomes. However, few studies have investigated major contributors to these uncertainties. This study investigated factors contributing to reducing uncertainty in delivering a dose to a target volume. The EBRT process was classified into four steps: reference dosimetry, relative dosimetry [percentage depth doses (PDDs) and off-center ratios (OCRs)], dose calculations (PDDs and OCRs in a virtual water phantom), and patient setup using an image-guided radiation therapy system. We evaluated the uncertainties for these steps in conventionally fractionated EBRT for intracranial disease using 4-, 6-, and 10-MV flattened photon beams generated from clinical linear accelerators following the Guide to the Expression of Uncertainty in Measurement and an uncertainty evaluation method with uncorrected deflection. The following were the major contributors to these uncertainties: beam quality conversion factors for reference dosimetry; charge measurements, chamber depth, source-to-surface distance, water evaporation, and field size for relative dosimetry; dose calculation accuracy for the dose calculations; image registration, radiation-imaging isocenter coincidence, variation in radiation isocenter due to gantry and couch rotation, and intrafractional motion for the patient setup. Among the four steps, the relative dosimetry and dose calculation (namely, both penumbral OCRs) steps involved an uncertainty of more than 5% with a coverage factor of 1. In the EBRT process evaluated herein, the uncertainties in the relative dosimetry and dose calculations must be reduced.
- 14 November 2024
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 18 (1) , 58-77
Open AccessQuantification of uncertainties in reference and relative dose measurements, dose calculations, and patient setup in modern external beam radiotherapy
Uncertainties in the steps of external beam radiotherapy (EBRT) affect patient outcomes. However, few studies have investigated major contributors to these uncertainties. This study investigated factors contributing to reducing uncertainty in delivering a dose to a target volume. The EBRT process was classified into four steps: reference dosimetry, relative dosimetry [percentage depth doses (PDDs) and off-center ratios (OCRs)], dose calculations (PDDs and OCRs in a virtual water phantom), and patient setup using an image-guided radiation therapy system. We evaluated the uncertainties for these steps in conventionally fractionated EBRT for intracranial disease using 4-, 6-, and 10-MV flattened photon beams generated from clinical linear accelerators following the Guide to the Expression of Uncertainty in Measurement and an uncertainty evaluation method with uncorrected deflection. The following were the major contributors to these uncertainties: beam quality conversion factors for reference dosimetry; charge measurements, chamber depth, source-to-surface distance, water evaporation, and field size for relative dosimetry; dose calculation accuracy for the dose calculations; image registration, radiation-imaging isocenter coincidence, variation in radiation isocenter due to gantry and couch rotation, and intrafractional motion for the patient setup. Among the four steps, the relative dosimetry and dose calculation (namely, both penumbral OCRs) steps involved an uncertainty of more than 5% with a coverage factor of 1. In the EBRT process evaluated herein, the uncertainties in the relative dosimetry and dose calculations must be reduced.
- Open Access
- 25 May 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (11) , 1851
[18F]FES PET Resolves the Diagnostic Dilemma of COVID-19-Vaccine-Associated Hypermetabolic Lymphadenopathy in ER-Positive Breast Cancer
Coronavirus disease (COVID-19) vaccination is known to cause a diagnostic dilemma due to false-positive findings on [18F]FDG PET in vaccine-associated hypermetabolic lymphadenopathy. We present two case reports of women with estrogen-receptor (ER)-positive cancer of the breast who were vaccinated for COVID-19 in the deltoid muscle. [18F]FDG positron emission tomography (PET) demonstrated primary breast cancer and multiple axillary lymph nodes with increased [18F]FDG uptake, diagnosed as vaccine-associated [18F]FDG-avid lymph nodes. Subsequent [18F]FES PET revealed single axillary lymph node metastasis in the vaccine-associated [18F]FDG-avid lymph nodes. To the best of our knowledge, this is the first study showing the usefulness of [18F]FES PET in diagnosing axillary lymph node metastasis in COVID-19-vaccinated patients harboring ER-positive breast cancer. Thus, [18F]FES PET has potential applications in the detection of true-positive metastatic lymph nodes in patients with ER-positive breast cancer regardless of the ipsilateral or contralateral side, who have received COVID-19 vaccination.
- 25 May 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (11) , 1851
Open Access[18F]FES PET Resolves the Diagnostic Dilemma of COVID-19-Vaccine-Associated Hypermetabolic Lymphadenopathy in ER-Positive Breast Cancer
Coronavirus disease (COVID-19) vaccination is known to cause a diagnostic dilemma due to false-positive findings on [18F]FDG PET in vaccine-associated hypermetabolic lymphadenopathy. We present two case reports of women with estrogen-receptor (ER)-positive cancer of the breast who were vaccinated for COVID-19 in the deltoid muscle. [18F]FDG positron emission tomography (PET) demonstrated primary breast cancer and multiple axillary lymph nodes with increased [18F]FDG uptake, diagnosed as vaccine-associated [18F]FDG-avid lymph nodes. Subsequent [18F]FES PET revealed single axillary lymph node metastasis in the vaccine-associated [18F]FDG-avid lymph nodes. To the best of our knowledge, this is the first study showing the usefulness of [18F]FES PET in diagnosing axillary lymph node metastasis in COVID-19-vaccinated patients harboring ER-positive breast cancer. Thus, [18F]FES PET has potential applications in the detection of true-positive metastatic lymph nodes in patients with ER-positive breast cancer regardless of the ipsilateral or contralateral side, who have received COVID-19 vaccination.