Sang-Hyun Jeon
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Sang-Hyun Jeon has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Chuluunbaatar Otgonbaatar
Medical Imaging AI Research Center, Canon Medical Systems Korea, Seoul, Republic of Korea
4 shared publications - Hackjoon Shim
Medical Imaging AI Research Center, Canon Medical Systems Korea, Seoul, Republic of Korea
3 shared publications - Hyunjung Kim
Department of Radiology, Wonju Severance Christian Hospital, Yonsei University Wonju College of Medicine, 20 Ilsan-ro, Wonju 26426, Republic of Korea
3 shared publications - Jhii-Hyun Ahn
Department of Radiology, Wonju Severance Christian Hospital, Yonsei University Wonju College of Medicine, Wonju, Republic of Korea
3 shared publications - Sung Min Ko
Department of Radiology, Wonju Severance Christian Hospital, Yonsei University Wonju College of Medicine, Wonju, Republic of Korea
3 shared publications - Sung-Jin Cha
Department of Radiology, Wonju Severance Christian Hospital, Yonsei University Wonju College of Medicine, Wonju, Republic of Korea
3 shared publications
Latest Publications
- Open Access
- 13 October 2026
- Published by Springer Nature in BMC Medical Imaging
Agreement of automated computed tomography body composition measurement across image reconstruction algorithms under identical projection data
- 13 October 2026
- Published by Springer Nature in BMC Medical Imaging
Open AccessAgreement of automated computed tomography body composition measurement across image reconstruction algorithms under identical projection data
- Open Access
- 22 September 2026
- Published by MDPI AG in Tomography
- Vol. 12 (10) , 138
Deep Learning–Based Reconstruction in Ultra-Low-Dose CT of the Ankle and Foot: A Comparative Study with Hybrid Iterative Reconstruction
Objectives: To evaluate the quantitative and qualitative performance of ultra-low-dose CT with deep learning image reconstruction (DLR) compared to conventional hybrid iterative reconstruction (IR) in patients with ankle and foot fractures. Methods: A total of 32 patients (mean age, 54 ± 16 years) with ankle and foot fractures were included in this retrospective study. All patients underwent ultra-low-dose CT imaging (effective dose, 0.86 ± 0.11 μSv), and the same CT raw data were reconstructed using both DLR and hybrid IR. Image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were quantitatively measured, and image sharpness was evaluated using a no-reference perceptual sharpness metric. Subjective image quality was assessed by a board-certified radiologist and an orthopedic surgeon using a five-point scale. Results: DLR significantly reduced image noise (47.33 ± 6.60 HU) compared to hybrid IR (87.65 ± 12.48 HU), and significantly improved SNR (31.42 ± 5.81 for DLR vs. 19.15 ± 4.48 for hybrid IR) and CNR (50.59 ± 7.62 for DLR vs. 24.08 ± 3.81 for hybrid IR). Image sharpness was significantly (p = 0.001) improved with DLR (0.76 ± 0.09) compared to hybrid IR (0.59 ± 0.09). Subjective image analysis revealed enhanced visualization of trabecular architecture, superior delineation and integrity of cortical bone, and improved depiction of bony cortical lesions with DLR compared to hybrid IR. Conclusions: Ultra-low-dose CT with DLR offers a superior approach to enhance image quality, making it a valuable tool for clinical practice.
- 22 September 2026
- Published by MDPI AG in Tomography
- Vol. 12 (10) , 138
Open AccessDeep Learning–Based Reconstruction in Ultra-Low-Dose CT of the Ankle and Foot: A Comparative Study with Hybrid Iterative Reconstruction
Objectives: To evaluate the quantitative and qualitative performance of ultra-low-dose CT with deep learning image reconstruction (DLR) compared to conventional hybrid iterative reconstruction (IR) in patients with ankle and foot fractures. Methods: A total of 32 patients (mean age, 54 ± 16 years) with ankle and foot fractures were included in this retrospective study. All patients underwent ultra-low-dose CT imaging (effective dose, 0.86 ± 0.11 μSv), and the same CT raw data were reconstructed using both DLR and hybrid IR. Image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were quantitatively measured, and image sharpness was evaluated using a no-reference perceptual sharpness metric. Subjective image quality was assessed by a board-certified radiologist and an orthopedic surgeon using a five-point scale. Results: DLR significantly reduced image noise (47.33 ± 6.60 HU) compared to hybrid IR (87.65 ± 12.48 HU), and significantly improved SNR (31.42 ± 5.81 for DLR vs. 19.15 ± 4.48 for hybrid IR) and CNR (50.59 ± 7.62 for DLR vs. 24.08 ± 3.81 for hybrid IR). Image sharpness was significantly (p = 0.001) improved with DLR (0.76 ± 0.09) compared to hybrid IR (0.59 ± 0.09). Subjective image analysis revealed enhanced visualization of trabecular architecture, superior delineation and integrity of cortical bone, and improved depiction of bony cortical lesions with DLR compared to hybrid IR. Conclusions: Ultra-low-dose CT with DLR offers a superior approach to enhance image quality, making it a valuable tool for clinical practice.
- Open Access
- 1 July 2026
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 16 (7) , 585
Vendor-agnostic versus vendor-specific boost methods in low-concentration contrast-enhanced computed tomography of the abdomen
Background: Contrast media-related adverse events pose serious risks, not only due to allergic reactions but also for patients with renal failure, older age, heart failure, and diabetes mellitus. Various efforts have been made to maximize vascular contrast enhancement (CE) using low-concentration contrast media. This study aimed to compare quantitative and qualitative image characteristics between vendor-agnostic and vendor-specific CE boost methods in low-concentration contrast medium settings against standard-concentration contrast medium settings. Methods: This retrospective study including 160 patients compared two concentrations of iodinated contrast media—350 mg I/mL (standard-concentration group) and 270 mg I/mL (low-concentration group) who underwent contrast-enhanced abdominal computed tomography (CT). Vendor-agnostic and vendor-specific boost methods were applied to the CT images of the low-concentration group. Quantitative [image noise, CT attenuation, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), noise power spectrum, and image sharpness] and qualitative (Likert scale rating by two radiologists) measures of image quality were evaluated in abdominal vessels and liver lesions. Results: The present study included 80 patients in the standard-concentration and 80 patients in the low-concentration group, respectively. There were no significant differences in age (P=0.75), sex (P=0.99), and body mass index (P=0.98) between the two groups. Both vendor-agnostic and vendor-specific CE-boost methods significantly reduced image noise (Pvs. 0.29±0.01; PConclusions: Although vendor-agnostic and vendor-specific CE-boost methods effectively enhanced image quality and CT attenuation in low-concentration contrast medium settings, subjective image analysis revealed lower ratings due to increased artificial appearance. The vendor-agnostic method provided superior image sharpness, whereas the vendor-specific method more effectively reduced structured noise and achieved higher subjective ratings for overall image quality, artificial suppression, and natural image appearance.
- 1 July 2026
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 16 (7) , 585
Open AccessVendor-agnostic versus vendor-specific boost methods in low-concentration contrast-enhanced computed tomography of the abdomen
Background: Contrast media-related adverse events pose serious risks, not only due to allergic reactions but also for patients with renal failure, older age, heart failure, and diabetes mellitus. Various efforts have been made to maximize vascular contrast enhancement (CE) using low-concentration contrast media. This study aimed to compare quantitative and qualitative image characteristics between vendor-agnostic and vendor-specific CE boost methods in low-concentration contrast medium settings against standard-concentration contrast medium settings. Methods: This retrospective study including 160 patients compared two concentrations of iodinated contrast media—350 mg I/mL (standard-concentration group) and 270 mg I/mL (low-concentration group) who underwent contrast-enhanced abdominal computed tomography (CT). Vendor-agnostic and vendor-specific boost methods were applied to the CT images of the low-concentration group. Quantitative [image noise, CT attenuation, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), noise power spectrum, and image sharpness] and qualitative (Likert scale rating by two radiologists) measures of image quality were evaluated in abdominal vessels and liver lesions. Results: The present study included 80 patients in the standard-concentration and 80 patients in the low-concentration group, respectively. There were no significant differences in age (P=0.75), sex (P=0.99), and body mass index (P=0.98) between the two groups. Both vendor-agnostic and vendor-specific CE-boost methods significantly reduced image noise (Pvs. 0.29±0.01; PConclusions: Although vendor-agnostic and vendor-specific CE-boost methods effectively enhanced image quality and CT attenuation in low-concentration contrast medium settings, subjective image analysis revealed lower ratings due to increased artificial appearance. The vendor-agnostic method provided superior image sharpness, whereas the vendor-specific method more effectively reduced structured noise and achieved higher subjective ratings for overall image quality, artificial suppression, and natural image appearance.
- Open Access
- 9 July 2025
- Published by MDPI AG in Journal of Cardiovascular Development and Disease
- Vol. 12 (7) , 264
Diagnostic Performance of Dynamic Myocardial Perfusion Imaging Using Third-Generation Dual-Source Computed Tomography in Patients with Intermediate Pretest Probability of Coronary Artery Disease
(1) Background: Our aim was to evaluate the diagnostic performance of combined coronary computed tomography angiography (CCTA) and dynamic CT myocardial perfusion imaging (CT-MPI) for detecting hemodynamically significant coronary artery disease (CAD) in patients with intermediate pretest probability. (2) Methods: Patients with an intermediate pretest probability of CAD were retrospectively enrolled. All patients underwent CCTA and dynamic CT-MPI using a third-generation dual-source CT scanner prior to invasive coronary angiography (ICA). Anatomically significant stenosis was defined as ≥50% luminal narrowing on both CCTA and ICA. Fractional flow reserve (FFR) was performed during ICA in selected cases. Hemodynamically significant CAD was defined per vessel as FFR ≤ 0.80, angiographic stenosis ≥70%, or having undergone revascularization. The diagnostic performance of CCTA alone and CCTA combined with CT-MPI was compared against this reference standard. (3) Results: Seventy-four patients (mean age, 66.8 ± 11.1 years; 59 men) were included. The median coronary calcium score was 508.5 Agatston units (interquartile range: 147–1173). ICA and CCTA detected anatomically significant stenoses in 137 (61.7%) and 146 (65.8%) coronary vessels, respectively, and in 62 (83.8%) and 71 (95.9%) patients, respectively. Hemodynamically significant stenosis was present in 56 patients (76%) and 99 vessels (45%). On a per-vessel basis, CCTA alone yielded a sensitivity of 96.7%, specificity of 60.3%, positive predictive value (PPV) of 64.4%, and negative predictive value (NPV) of 96.1%. Combined CCTA and CT-MPI demonstrated a sensitivity of 90.1%, specificity of 84.3%, PPV of 82.7%, and NPV of 91.1%. The area under the receiver operating characteristic curve improved from 0.787 (95% confidence interval: 0.73–0.84) for CCTA to 0.872 (95% confidence interval: 0.82–0.91) for the combined approach (p < 0.05). The median total radiation dose for both CCTA and CT-MPI was 8.05 mSv (interquartile range: 6.71–11.0). (4) Conclusions: In patients with intermediate pretest probability of CAD, combining CCTA with dynamic CT-MPI significantly enhances the diagnostic performance for identifying hemodynamically significant coronary stenosis compared to CCTA alone.
- 9 July 2025
- Published by MDPI AG in Journal of Cardiovascular Development and Disease
- Vol. 12 (7) , 264
Open AccessDiagnostic Performance of Dynamic Myocardial Perfusion Imaging Using Third-Generation Dual-Source Computed Tomography in Patients with Intermediate Pretest Probability of Coronary Artery Disease
(1) Background: Our aim was to evaluate the diagnostic performance of combined coronary computed tomography angiography (CCTA) and dynamic CT myocardial perfusion imaging (CT-MPI) for detecting hemodynamically significant coronary artery disease (CAD) in patients with intermediate pretest probability. (2) Methods: Patients with an intermediate pretest probability of CAD were retrospectively enrolled. All patients underwent CCTA and dynamic CT-MPI using a third-generation dual-source CT scanner prior to invasive coronary angiography (ICA). Anatomically significant stenosis was defined as ≥50% luminal narrowing on both CCTA and ICA. Fractional flow reserve (FFR) was performed during ICA in selected cases. Hemodynamically significant CAD was defined per vessel as FFR ≤ 0.80, angiographic stenosis ≥70%, or having undergone revascularization. The diagnostic performance of CCTA alone and CCTA combined with CT-MPI was compared against this reference standard. (3) Results: Seventy-four patients (mean age, 66.8 ± 11.1 years; 59 men) were included. The median coronary calcium score was 508.5 Agatston units (interquartile range: 147–1173). ICA and CCTA detected anatomically significant stenoses in 137 (61.7%) and 146 (65.8%) coronary vessels, respectively, and in 62 (83.8%) and 71 (95.9%) patients, respectively. Hemodynamically significant stenosis was present in 56 patients (76%) and 99 vessels (45%). On a per-vessel basis, CCTA alone yielded a sensitivity of 96.7%, specificity of 60.3%, positive predictive value (PPV) of 64.4%, and negative predictive value (NPV) of 96.1%. Combined CCTA and CT-MPI demonstrated a sensitivity of 90.1%, specificity of 84.3%, PPV of 82.7%, and NPV of 91.1%. The area under the receiver operating characteristic curve improved from 0.787 (95% confidence interval: 0.73–0.84) for CCTA to 0.872 (95% confidence interval: 0.82–0.91) for the combined approach (p < 0.05). The median total radiation dose for both CCTA and CT-MPI was 8.05 mSv (interquartile range: 6.71–11.0). (4) Conclusions: In patients with intermediate pretest probability of CAD, combining CCTA with dynamic CT-MPI significantly enhances the diagnostic performance for identifying hemodynamically significant coronary stenosis compared to CCTA alone.
- Open Access
- 26 May 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (11) , 1862
Assessment of Image Quality of Coronary CT Angiography Using Deep Learning-Based CT Reconstruction: Phantom and Patient Studies
Background: In coronary computed tomography angiography (CCTA), the main issue of image quality is noise in obese patients, blooming artifacts due to calcium and stents, high-risk coronary plaques, and radiation exposure to patients. Objective: To compare the CCTA image quality of deep learning-based reconstruction (DLR) with that of filtered back projection (FBP) and iterative reconstruction (IR). Methods: This was a phantom study of 90 patients who underwent CCTA. CCTA images were acquired using FBP, IR, and DLR. In the phantom study, the aortic root and the left main coronary artery in the chest phantom were simulated using a needleless syringe. The patients were classified into three groups according to their body mass index. Noise, the signal-to-noise ratio (SNR), and the contrast-to-noise ratio (CNR) were measured for image quantification. A subjective analysis was also performed for FBP, IR, and DLR. Results: According to the phantom study, DLR reduced noise by 59.8% compared to FBP and increased SNR and CNR by 121.4% and 123.6%, respectively. In a patient study, DLR reduced noise compared to FBP and IR. Furthermore, DLR increased the SNR and CNR more than FBP and IR. In terms of subjective scores, DLR was higher than FBP and IR. Conclusion: In both phantom and patient studies, DLR effectively reduced image noise and improved SNR and CNR. Therefore, the DLR may be useful for CCTA examinations.
- 26 May 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (11) , 1862
Open AccessAssessment of Image Quality of Coronary CT Angiography Using Deep Learning-Based CT Reconstruction: Phantom and Patient Studies
Background: In coronary computed tomography angiography (CCTA), the main issue of image quality is noise in obese patients, blooming artifacts due to calcium and stents, high-risk coronary plaques, and radiation exposure to patients. Objective: To compare the CCTA image quality of deep learning-based reconstruction (DLR) with that of filtered back projection (FBP) and iterative reconstruction (IR). Methods: This was a phantom study of 90 patients who underwent CCTA. CCTA images were acquired using FBP, IR, and DLR. In the phantom study, the aortic root and the left main coronary artery in the chest phantom were simulated using a needleless syringe. The patients were classified into three groups according to their body mass index. Noise, the signal-to-noise ratio (SNR), and the contrast-to-noise ratio (CNR) were measured for image quantification. A subjective analysis was also performed for FBP, IR, and DLR. Results: According to the phantom study, DLR reduced noise by 59.8% compared to FBP and increased SNR and CNR by 121.4% and 123.6%, respectively. In a patient study, DLR reduced noise compared to FBP and IR. Furthermore, DLR increased the SNR and CNR more than FBP and IR. In terms of subjective scores, DLR was higher than FBP and IR. Conclusion: In both phantom and patient studies, DLR effectively reduced image noise and improved SNR and CNR. Therefore, the DLR may be useful for CCTA examinations.