Latest Publications

  • Open Access

    Agreement of automated computed tomography body composition measurement across image reconstruction algorithms under identical projection data

    by Chuluunbaatar Otgonbaatar, Hyunjung Kim, Jin Woo Kim, Gonchigsuren Dagvasumberel, Sung-Jin Cha, Sang-Hyun Jeon, Hackjoon Shim, Jhii-Hyun Ahn

  • Open Access

    Deep Learning–Based Reconstruction in Ultra-Low-Dose CT of the Ankle and Foot: A Comparative Study with Hybrid Iterative Reconstruction

    by Chuluunbaatar Otgonbaatar, Jin Woo Kim, Sung-Jin Cha, Sang-Hyun Jeon, Gonchigsuren Dagvasumberel, Hackjoon Shim, Young Hwan Jang, Jhii-Hyun Ahn, Sung Min Ko, Hyunjung Kim

    Objectives: To evaluate the quantitative and qualitative performance of ultra-low-dose CT with deep learning image reconstruction (DLR) compared to conventional hybrid iterative reconstruction (IR) in patients with ankle and foot fractures. Methods: A total of 32 patients (mean age, 54 ± 16 years) with ankle and foot fractures were included in this retrospective study. All patients underwent ultra-low-dose CT imaging (effective dose, 0.86 ± 0.11 μSv), and the same CT raw data were reconstructed using both DLR and hybrid IR. Image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were quantitatively measured, and image sharpness was evaluated using a no-reference perceptual sharpness metric. Subjective image quality was assessed by a board-certified radiologist and an orthopedic surgeon using a five-point scale. Results: DLR significantly reduced image noise (47.33 ± 6.60 HU) compared to hybrid IR (87.65 ± 12.48 HU), and significantly improved SNR (31.42 ± 5.81 for DLR vs. 19.15 ± 4.48 for hybrid IR) and CNR (50.59 ± 7.62 for DLR vs. 24.08 ± 3.81 for hybrid IR). Image sharpness was significantly (p = 0.001) improved with DLR (0.76 ± 0.09) compared to hybrid IR (0.59 ± 0.09). Subjective image analysis revealed enhanced visualization of trabecular architecture, superior delineation and integrity of cortical bone, and improved depiction of bony cortical lesions with DLR compared to hybrid IR. Conclusions: Ultra-low-dose CT with DLR offers a superior approach to enhance image quality, making it a valuable tool for clinical practice.

  • Open Access

    Vendor-agnostic versus vendor-specific boost methods in low-concentration contrast-enhanced computed tomography of the abdomen

    by Chuluunbaatar Otgonbaatar, Sung-Jin Cha, Sang-Hyun Jeon, Sue Yon Shim, Hackjoon Shim, Jhii-Hyun Ahn

    Background: Contrast media-related adverse events pose serious risks, not only due to allergic reactions but also for patients with renal failure, older age, heart failure, and diabetes mellitus. Various efforts have been made to maximize vascular contrast enhancement (CE) using low-concentration contrast media. This study aimed to compare quantitative and qualitative image characteristics between vendor-agnostic and vendor-specific CE boost methods in low-concentration contrast medium settings against standard-concentration contrast medium settings. Methods: This retrospective study including 160 patients compared two concentrations of iodinated contrast media—350 mg I/mL (standard-concentration group) and 270 mg I/mL (low-concentration group) who underwent contrast-enhanced abdominal computed tomography (CT). Vendor-agnostic and vendor-specific boost methods were applied to the CT images of the low-concentration group. Quantitative [image noise, CT attenuation, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), noise power spectrum, and image sharpness] and qualitative (Likert scale rating by two radiologists) measures of image quality were evaluated in abdominal vessels and liver lesions. Results: The present study included 80 patients in the standard-concentration and 80 patients in the low-concentration group, respectively. There were no significant differences in age (P=0.75), sex (P=0.99), and body mass index (P=0.98) between the two groups. Both vendor-agnostic and vendor-specific CE-boost methods significantly reduced image noise (Pvs. 0.29±0.01; PConclusions: Although vendor-agnostic and vendor-specific CE-boost methods effectively enhanced image quality and CT attenuation in low-concentration contrast medium settings, subjective image analysis revealed lower ratings due to increased artificial appearance. The vendor-agnostic method provided superior image sharpness, whereas the vendor-specific method more effectively reduced structured noise and achieved higher subjective ratings for overall image quality, artificial suppression, and natural image appearance.

  • Open Access

    Diagnostic Performance of Dynamic Myocardial Perfusion Imaging Using Third-Generation Dual-Source Computed Tomography in Patients with Intermediate Pretest Probability of Coronary Artery Disease

    by Sung Min Ko, Sung-Jin Cha, Hyunjung Kim, Pil-Hyun Jeon, Sang-Hyun Jeon, Sung Gyun Ahn, Jung-Woo Son

    (1) Background: Our aim was to evaluate the diagnostic performance of combined coronary computed tomography angiography (CCTA) and dynamic CT myocardial perfusion imaging (CT-MPI) for detecting hemodynamically significant coronary artery disease (CAD) in patients with intermediate pretest probability. (2) Methods: Patients with an intermediate pretest probability of CAD were retrospectively enrolled. All patients underwent CCTA and dynamic CT-MPI using a third-generation dual-source CT scanner prior to invasive coronary angiography (ICA). Anatomically significant stenosis was defined as ≥50% luminal narrowing on both CCTA and ICA. Fractional flow reserve (FFR) was performed during ICA in selected cases. Hemodynamically significant CAD was defined per vessel as FFR ≤ 0.80, angiographic stenosis ≥70%, or having undergone revascularization. The diagnostic performance of CCTA alone and CCTA combined with CT-MPI was compared against this reference standard. (3) Results: Seventy-four patients (mean age, 66.8 ± 11.1 years; 59 men) were included. The median coronary calcium score was 508.5 Agatston units (interquartile range: 147–1173). ICA and CCTA detected anatomically significant stenoses in 137 (61.7%) and 146 (65.8%) coronary vessels, respectively, and in 62 (83.8%) and 71 (95.9%) patients, respectively. Hemodynamically significant stenosis was present in 56 patients (76%) and 99 vessels (45%). On a per-vessel basis, CCTA alone yielded a sensitivity of 96.7%, specificity of 60.3%, positive predictive value (PPV) of 64.4%, and negative predictive value (NPV) of 96.1%. Combined CCTA and CT-MPI demonstrated a sensitivity of 90.1%, specificity of 84.3%, PPV of 82.7%, and NPV of 91.1%. The area under the receiver operating characteristic curve improved from 0.787 (95% confidence interval: 0.73–0.84) for CCTA to 0.872 (95% confidence interval: 0.82–0.91) for the combined approach (p < 0.05). The median total radiation dose for both CCTA and CT-MPI was 8.05 mSv (interquartile range: 6.71–11.0). (4) Conclusions: In patients with intermediate pretest probability of CAD, combining CCTA with dynamic CT-MPI significantly enhances the diagnostic performance for identifying hemodynamically significant coronary stenosis compared to CCTA alone.


  • Open Access

    Assessment of Image Quality of Coronary CT Angiography Using Deep Learning-Based CT Reconstruction: Phantom and Patient Studies

    by Pil-Hyun Jeon, Sang-Hyun Jeon, Donghee Ko, Giyong An, Hackjoon Shim, Chuluunbaatar Otgonbaatar, Kihong Son, Daehong Kim, Sung Min Ko, Myung-Ae Chung

    Background: In coronary computed tomography angiography (CCTA), the main issue of image quality is noise in obese patients, blooming artifacts due to calcium and stents, high-risk coronary plaques, and radiation exposure to patients. Objective: To compare the CCTA image quality of deep learning-based reconstruction (DLR) with that of filtered back projection (FBP) and iterative reconstruction (IR). Methods: This was a phantom study of 90 patients who underwent CCTA. CCTA images were acquired using FBP, IR, and DLR. In the phantom study, the aortic root and the left main coronary artery in the chest phantom were simulated using a needleless syringe. The patients were classified into three groups according to their body mass index. Noise, the signal-to-noise ratio (SNR), and the contrast-to-noise ratio (CNR) were measured for image quantification. A subjective analysis was also performed for FBP, IR, and DLR. Results: According to the phantom study, DLR reduced noise by 59.8% compared to FBP and increased SNR and CNR by 121.4% and 123.6%, respectively. In a patient study, DLR reduced noise compared to FBP and IR. Furthermore, DLR increased the SNR and CNR more than FBP and IR. In terms of subjective scores, DLR was higher than FBP and IR. Conclusion: In both phantom and patient studies, DLR effectively reduced image noise and improved SNR and CNR. Therefore, the DLR may be useful for CCTA examinations.