Dapeng Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Dapeng Liu has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
Hongju Yang
Department of Surgical Anesthesiology The First Affiliated Hospital of Xinjiang Medical University Urumqi China
4 shared publicationsJinghao Liang
Department of Orthopedics People's Hospital of Xinjiang Uygur Autonomous Region Urumqi China
4 shared publicationsBotian Ouyang
Department of Emergency Medicine, The Fifth Affiliated Hospital, Southern Medical University, Guangzhou 510999, China
1 shared publicationGuoxiang Jiang
Haikou Orthopedic and Diabetes Hospital of Shanghai Sixth People’s Hospital
1 shared publicationHongyu Zhao
Department of Bone Disease and Bone Tumor, Shenyang Orthopedic Hospital, Shenyang, Liaoning, China
1 shared publicationJing Lin
Department of Orthopaedics, The Fourth People’s Hospital of Haikou, Haikou, Hainan, China
1 shared publication
Latest Publications
- Open Access
- 2 November 2026
- Published by Wolters Kluwer Health in Spine Open
- Vol. 2 (4)
Extracorporeal Spinal Orthosis-Fixation With Progressive Distraction for Severe Spinal Tuberculosis Kyphosis: A Technical Case Series With Long-Term Follow-Up
Study Design: Retrospective technical case series. Objective: To describe the technical feasibility and long-term outcomes and radiographic experience of an extracorporeal spinal orthosis-fixation (ESOF) device combined with a progressive-adaptive distraction in highly selected patients with severe multilevel spinal tuberculosis (TB) kyphosis. Summary of Background Data: Severe spinal TB with extensive vertebral destruction may result in marked kyphosis, spinal shortening, and substantial bone loss. Conventional reconstruction can be technically challenging when multiple contiguous vertebral segments(≥3) and a Cobb Angle of ≥70° are involved. The feasibility of gradual deformity correction combined with progressive spinal lengthening in this severe setting has not been well described. Materials and Methods: Three patients with severe multilevel spinal TB deformity were retrospectively reviewed. They had extensive vertebral destruction involving three to seven vertebral segments and a preoperative Cobb Angle of ≥70°. Treatment consisted of anterior debridement and bone grafting, posterior placement of extra-long pedicle screws with an ESOF device, and postoperative progressive-adaptive distraction. Simultaneously, anti-TB drug treatment was administered for one and a half years before, during, and after surgery, including at the lesion site and during postoperative traction. Clinical and radiographic observations included Cobb Angle, spinal-pelvic tilt, standing height, erythrocyte sedimentation rate (ESR), C-reactive protein (CRP), Oswestry Disability Index (ODI), neurological status, and complications during three phases: distraction orthopedic phase, distraction osteogenesis phase, and long-term follow-up, respectively. Results: The mean preoperative Cobb Angle was 80.3°. During the initial distraction phase, lasting a mean of 71.3 days, the mean Cobb Angle decreased to 21.7°, and the mean standing height increased by 5.3 cm. During the subsequent distraction osteogenesis phase, lasting a mean of 2 years 4 months, the mean Cobb Angle was 12.7° and the mean height gain reached 7.0 cm, with radiographic evidence of new bone formation. At a mean follow-up of 12.3 years, the mean Cobb Angle was 17.0°, the mean height gain was 6.7 cm, and the mean ODI was 3.0. One patient developed a mild screw-hole infection that resolved with local wound care; two patients reported painless lumbar popping. No neurological deterioration or other major adverse event was observed. Conclusions: In this small, highly selected retrospective technical series, ESOF combined with progressive-adaptive distraction was technically feasible and was associated with substantial deformity correction and long-term maintenance of spinal alignment. These observations should be considered preliminary proof-of-concept findings rather than evidence establishing the safety or efficacy of the technique. Further studies are required to determine reproducibility, complication rates, and clinical effectiveness.
- 2 November 2026
- Published by Wolters Kluwer Health in Spine Open
- Vol. 2 (4)
Open AccessExtracorporeal Spinal Orthosis-Fixation With Progressive Distraction for Severe Spinal Tuberculosis Kyphosis: A Technical Case Series With Long-Term Follow-Up
Study Design: Retrospective technical case series. Objective: To describe the technical feasibility and long-term outcomes and radiographic experience of an extracorporeal spinal orthosis-fixation (ESOF) device combined with a progressive-adaptive distraction in highly selected patients with severe multilevel spinal tuberculosis (TB) kyphosis. Summary of Background Data: Severe spinal TB with extensive vertebral destruction may result in marked kyphosis, spinal shortening, and substantial bone loss. Conventional reconstruction can be technically challenging when multiple contiguous vertebral segments(≥3) and a Cobb Angle of ≥70° are involved. The feasibility of gradual deformity correction combined with progressive spinal lengthening in this severe setting has not been well described. Materials and Methods: Three patients with severe multilevel spinal TB deformity were retrospectively reviewed. They had extensive vertebral destruction involving three to seven vertebral segments and a preoperative Cobb Angle of ≥70°. Treatment consisted of anterior debridement and bone grafting, posterior placement of extra-long pedicle screws with an ESOF device, and postoperative progressive-adaptive distraction. Simultaneously, anti-TB drug treatment was administered for one and a half years before, during, and after surgery, including at the lesion site and during postoperative traction. Clinical and radiographic observations included Cobb Angle, spinal-pelvic tilt, standing height, erythrocyte sedimentation rate (ESR), C-reactive protein (CRP), Oswestry Disability Index (ODI), neurological status, and complications during three phases: distraction orthopedic phase, distraction osteogenesis phase, and long-term follow-up, respectively. Results: The mean preoperative Cobb Angle was 80.3°. During the initial distraction phase, lasting a mean of 71.3 days, the mean Cobb Angle decreased to 21.7°, and the mean standing height increased by 5.3 cm. During the subsequent distraction osteogenesis phase, lasting a mean of 2 years 4 months, the mean Cobb Angle was 12.7° and the mean height gain reached 7.0 cm, with radiographic evidence of new bone formation. At a mean follow-up of 12.3 years, the mean Cobb Angle was 17.0°, the mean height gain was 6.7 cm, and the mean ODI was 3.0. One patient developed a mild screw-hole infection that resolved with local wound care; two patients reported painless lumbar popping. No neurological deterioration or other major adverse event was observed. Conclusions: In this small, highly selected retrospective technical series, ESOF combined with progressive-adaptive distraction was technically feasible and was associated with substantial deformity correction and long-term maintenance of spinal alignment. These observations should be considered preliminary proof-of-concept findings rather than evidence establishing the safety or efficacy of the technique. Further studies are required to determine reproducibility, complication rates, and clinical effectiveness.
- 5 July 2024
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 20 (4) , e2656
Combining robotics and 3D printing facilitates closed reduction of humeral shaft fractures using a minimally invasive plate as a reduction template: A proof‐of‐concept study
Background: Minimally invasive percutaneous plate osteosynthesis for humeral shaft fractures (HSFs) has limitations due to malreduction and radiation exposure. To address these limitations, we integrated robotics and 3D printing by incorporating plates as reduction templates.Method: The innovative technology facilitated closed reduction of HSFs in the operating theatre using 18 models with cortical marking holes. The dataset of the precontoured plate was imported into 3D planning software for virtual fixation and screw path planning. The models were divided into half to simulate transverse fractures. During the operation, the software generated drilling trajectories for robot navigation, and precise plate installation achieved automatic fracture reduction.Results: The evaluation results of reduction accuracy revealed variations in length, apposition, alignment, and rotation that meet the criteria for anatomic reduction. High interoperator reliabilities were observed for all parameters.Conclusions: The proposed technology achieved anatomic reduction in simulated bones.
- 5 July 2024
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 20 (4) , e2656
Combining robotics and 3D printing facilitates closed reduction of humeral shaft fractures using a minimally invasive plate as a reduction template: A proof‐of‐concept study
Background: Minimally invasive percutaneous plate osteosynthesis for humeral shaft fractures (HSFs) has limitations due to malreduction and radiation exposure. To address these limitations, we integrated robotics and 3D printing by incorporating plates as reduction templates.Method: The innovative technology facilitated closed reduction of HSFs in the operating theatre using 18 models with cortical marking holes. The dataset of the precontoured plate was imported into 3D planning software for virtual fixation and screw path planning. The models were divided into half to simulate transverse fractures. During the operation, the software generated drilling trajectories for robot navigation, and precise plate installation achieved automatic fracture reduction.Results: The evaluation results of reduction accuracy revealed variations in length, apposition, alignment, and rotation that meet the criteria for anatomic reduction. High interoperator reliabilities were observed for all parameters.Conclusions: The proposed technology achieved anatomic reduction in simulated bones.
- 7 December 2023
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 123 (1) , 104079
A novel technology integrating robotics and 3D printing for closed reduction of tibia shaft fracture with MIPPO:A proof-of-concept study
Less invasive fixation techniques, such as intramedullary nailing (IMN) and minimally invasive percutaneous plate osteosynthesis (MIPPO), are now the preferred choices for treating tibia shaft fractures (TSFs). However, malreduction and radiation exposure are the main deficiencies associated with less invasive fixation techniques, especially when assessing rotation around the shaft axis intra-operatively. The purpose of this study was to investigate the feasibility and reduction accuracy of an innovative technology that integrates robotics and 3D printing for achieving anatomical reduction of TSFs with MIPPO. The surgical workflow from a standardized CT protocol, via 3D reconstruction, 3D printing tibia model, pre-contouring plate, 3D scanning plate, 3D planning of the trajectories of the robot, and use of a commercial surgical robot, robot-assisted screw hole drilling, to automatic fracture reduction through precise installation of the plate was described. The reduction accuracy was evaluated by an optical tracking system. The mean variations of 1.95 ± 1.36mm in length, 1.63 ± 0.92 mm in apposition, 2.78 ± 1.69° in alignment, and 1.99 ± 1.81° in rotation. The interoperator reliabilities were almost perfect, with values of 0.91, 0.93, 0.92, and 0.90, respectively. The proposed technology achieved anatomic reduction on phantom bones.
- 7 December 2023
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 123 (1) , 104079
A novel technology integrating robotics and 3D printing for closed reduction of tibia shaft fracture with MIPPO:A proof-of-concept study
Less invasive fixation techniques, such as intramedullary nailing (IMN) and minimally invasive percutaneous plate osteosynthesis (MIPPO), are now the preferred choices for treating tibia shaft fractures (TSFs). However, malreduction and radiation exposure are the main deficiencies associated with less invasive fixation techniques, especially when assessing rotation around the shaft axis intra-operatively. The purpose of this study was to investigate the feasibility and reduction accuracy of an innovative technology that integrates robotics and 3D printing for achieving anatomical reduction of TSFs with MIPPO. The surgical workflow from a standardized CT protocol, via 3D reconstruction, 3D printing tibia model, pre-contouring plate, 3D scanning plate, 3D planning of the trajectories of the robot, and use of a commercial surgical robot, robot-assisted screw hole drilling, to automatic fracture reduction through precise installation of the plate was described. The reduction accuracy was evaluated by an optical tracking system. The mean variations of 1.95 ± 1.36mm in length, 1.63 ± 0.92 mm in apposition, 2.78 ± 1.69° in alignment, and 1.99 ± 1.81° in rotation. The interoperator reliabilities were almost perfect, with values of 0.91, 0.93, 0.92, and 0.90, respectively. The proposed technology achieved anatomic reduction on phantom bones.
- 2 August 2023
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 143 (11) , 6657-6664
Medial minimally invasive percutaneous plate osteosynthesis for humeral shaft fractures: a case series and novel technique description
Introduction Minimally Invasive Percutaneous Plate Osteosynthesis (MIPPO) is increasingly favored for treating humeral shaft fractures (HSFs). However, conventional MIPPO techniques pose challenges in fixing fractures near fossa olecranon and carry a risk of iatrogenic radial nerve palsy. A novel technique using a medial MIPPO for treating humeral shaft fractures (HSFs) is described. Results of clinical follow-up are presented. Materials and methods This study is a retrospective case series study. Twenty-one patients (mean age 43.9 ± 17.66 [22‒81] years) with HSFs were treated with the novel MIPPO fixation method. Clinical outcomes including time for radiographic consolidation, Disabilities of the Arm, Shoulder, and Hand (DASH) score, and complications were assessed at the last follow-up. The mean follow-up was 26 ± 17.12 (range 12–67) months. Results All patients had a bony union at a mean of 15.76 ± 6.74 (range 8–40) weeks based on X-ray with an early and aggressive range of motion. The complication rate was 0. The mean DASH score was3.29 ± 4.09 (range 0–14.17) at the time of the last follow-up. The mean screw density was 0.49 ± 0.1 (range 0.2–0.65). Conclusion This novel surgical technique for HSFs is a viable alternative to previously described methods with the advantage of being less prone to nerve injury and easy to fix distal extra-articular HSFs. The learning curve is short. Level of evidence IV.
- 2 August 2023
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 143 (11) , 6657-6664
Medial minimally invasive percutaneous plate osteosynthesis for humeral shaft fractures: a case series and novel technique description
Introduction Minimally Invasive Percutaneous Plate Osteosynthesis (MIPPO) is increasingly favored for treating humeral shaft fractures (HSFs). However, conventional MIPPO techniques pose challenges in fixing fractures near fossa olecranon and carry a risk of iatrogenic radial nerve palsy. A novel technique using a medial MIPPO for treating humeral shaft fractures (HSFs) is described. Results of clinical follow-up are presented. Materials and methods This study is a retrospective case series study. Twenty-one patients (mean age 43.9 ± 17.66 [22‒81] years) with HSFs were treated with the novel MIPPO fixation method. Clinical outcomes including time for radiographic consolidation, Disabilities of the Arm, Shoulder, and Hand (DASH) score, and complications were assessed at the last follow-up. The mean follow-up was 26 ± 17.12 (range 12–67) months. Results All patients had a bony union at a mean of 15.76 ± 6.74 (range 8–40) weeks based on X-ray with an early and aggressive range of motion. The complication rate was 0. The mean DASH score was3.29 ± 4.09 (range 0–14.17) at the time of the last follow-up. The mean screw density was 0.49 ± 0.1 (range 0.2–0.65). Conclusion This novel surgical technique for HSFs is a viable alternative to previously described methods with the advantage of being less prone to nerve injury and easy to fix distal extra-articular HSFs. The learning curve is short. Level of evidence IV.
- Open Access
- 5 June 2023
- Published by Springer Nature in Research Square
A new technology combined robotics and 3D printing facilitates closed reduction of tibia shaft fractures using a minimally invasive plate as a reduction template: A technical note.
Less invasive fixation techniques are the mainstay in the treatment of tibial shaft fractures (TSFs), Intramedullary nailing (IMN) and minimally invasive plate osteosynthesis (MIPPO) are the least invasive and the preferred choices used nowadays. However, malreduction and radiation exposure are the main deficiencies associated with less invasive fixation techniques, especially rotation around the shaft axis is difficult to assess intra-operatively. Our focus is on describing a novel technology that integrates robotics and 3D printing to facilitate closed reduction of Tibial shaft fractures using minimally invasive plates as reduction templates. Using this technique, we have achieved anatomic reduction on phantom bone.
- 5 June 2023
- Published by Springer Nature in Research Square
Open AccessA new technology combined robotics and 3D printing facilitates closed reduction of tibia shaft fractures using a minimally invasive plate as a reduction template: A technical note.
Less invasive fixation techniques are the mainstay in the treatment of tibial shaft fractures (TSFs), Intramedullary nailing (IMN) and minimally invasive plate osteosynthesis (MIPPO) are the least invasive and the preferred choices used nowadays. However, malreduction and radiation exposure are the main deficiencies associated with less invasive fixation techniques, especially rotation around the shaft axis is difficult to assess intra-operatively. Our focus is on describing a novel technology that integrates robotics and 3D printing to facilitate closed reduction of Tibial shaft fractures using minimally invasive plates as reduction templates. Using this technique, we have achieved anatomic reduction on phantom bone.
- Open Access
- 17 May 2023
- Published by Wolters Kluwer Health in Annals of Medicine & Surgery
- Vol. 85 (6) , 3171-3178
Medial minimally invasive plate osteosynthesis for humeral shaft fractures: a case series
Background: Minimally invasive plate osteosynthesis (MIPO) is increasingly favored for treating humeral shaft fractures (HSFs). However, conventional MIPO techniques pose challenges in fixing fractures near the fossa olecrani and carry a high risk of iatrogenic radial nerve palsy. This study was aimed to report the clinical outcomes of a series of patients who underwent MIPO through a medial approach for HSFs and describe our treatment algorithm. Patients and Method: This is a study conducted in our university hospital, which is a Level 1 academic trauma center. A retrospective analysis of 21 patients with HSFs who received minimally invasive treatment using plate osteosynthesis through a medial approach over a 5-year period was conducted. The outcomes measured included time for radiographic consolidation, disabilities of the arm, shoulder, and hand score, and complications such as infection, iatrogenic radial nerve injury, loss of reduction or fixation, and nonunion. Results: Twenty-one patients who underwent the procedure were identified. Bone healing was achieved in all patients with an early and aggressive range of motion. There were no cases of infection or iatrogenic radial nerve injury. The mean radiographic fracture union time was 15.76 weeks (range: 8–40 weeks). The mean disabilities of the arm, shoulder, and hand score was 3.29 (range: 0–14.17) at the time of the last follow-up. The mean screw density was 0.43. Conclusion: The proposed algorithm is effective in addressing the challenges of iatrogenic nerve injury and extra-articular distal fixation of HSFs with conventional MIPO techniques.
- 17 May 2023
- Published by Wolters Kluwer Health in Annals of Medicine & Surgery
- Vol. 85 (6) , 3171-3178
Open AccessMedial minimally invasive plate osteosynthesis for humeral shaft fractures: a case series
Background: Minimally invasive plate osteosynthesis (MIPO) is increasingly favored for treating humeral shaft fractures (HSFs). However, conventional MIPO techniques pose challenges in fixing fractures near the fossa olecrani and carry a high risk of iatrogenic radial nerve palsy. This study was aimed to report the clinical outcomes of a series of patients who underwent MIPO through a medial approach for HSFs and describe our treatment algorithm. Patients and Method: This is a study conducted in our university hospital, which is a Level 1 academic trauma center. A retrospective analysis of 21 patients with HSFs who received minimally invasive treatment using plate osteosynthesis through a medial approach over a 5-year period was conducted. The outcomes measured included time for radiographic consolidation, disabilities of the arm, shoulder, and hand score, and complications such as infection, iatrogenic radial nerve injury, loss of reduction or fixation, and nonunion. Results: Twenty-one patients who underwent the procedure were identified. Bone healing was achieved in all patients with an early and aggressive range of motion. There were no cases of infection or iatrogenic radial nerve injury. The mean radiographic fracture union time was 15.76 weeks (range: 8–40 weeks). The mean disabilities of the arm, shoulder, and hand score was 3.29 (range: 0–14.17) at the time of the last follow-up. The mean screw density was 0.43. Conclusion: The proposed algorithm is effective in addressing the challenges of iatrogenic nerve injury and extra-articular distal fixation of HSFs with conventional MIPO techniques.