Kaustubh Gopal
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Kaustubh Gopal has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Caroline Park
University of Texas Southwestern Medical Center
2 shared publications Herbert J. Zeh
Department of Surgery, Artificial Intelligence and Medical Simulation Lab, University of Texas Southwestern Medical Center, Dallas, USA
2 shared publicationsA. Desir
Division of General and Acute Care Surgery, University of Texas Southwestern Medical Center, Dallas Texas
1 shared publicationA. Franklin
University of Texas Southwestern Medical Center, Department of Orthopedic Surgery, Dallas, TX, USA
1 shared publicationA. Starr
University of Texas Southwestern Medical Center, Department of Orthopedic Surgery, Dallas, TX, USA
1 shared publicationAlexis Desir
Department of Surgery, Artificial Intelligence and Medical Simulation Lab, University of Texas Southwestern Medical Center, Dallas, USA
1 shared publication
Latest Publications
- 22 July 2025
- Published by Springer Nature in Surgical Endoscopy
- Vol. 39 (9) , 5820-5829
Robotic malfunction checklist: a guide to operating room safety, efficiency, and surgeon autonomy
Importance Surgical robots encounter malfunctions requiring swift resolution, impacting patient safety and surgical efficiency. A Robotic Malfunction Checklist (RMC) may enhance surgical team autonomy reduce stress and intraoperative downtime. Objective To assess the efficacy of a step-by-step RMC for troubleshooting surgical robot errors through a randomized controlled trial simulation. Design An IRB-approved study conducted a needs analysis to identify common robotic errors. A specialized RMC was then developed and tested in a randomized simulation setting, utilizing the da Vinci Xi system. Setting Simulation environment utilizing the da Vinci Xi surgical robot system. Participants Thirty-one participants, including surgery residents and attendings were allocated to either the control (n = 16) or experimental groups (n = 15). Interventions Control group participants addressed errors conventionally, while experimental group members utilized the RMC for troubleshooting. Main outcomes and measures Post-survey data, including NASA Task Load Index (TLX) scores were collected to assess task load and confidence in troubleshooting. Statistical analysis involved the Mann–Whitney U test and Fischer's exact test. Results The experimental group significantly expedited resolution of the third complex error (3.9 min; IQR = 5.2; P < 0.01), representing a 43% reduction in resolution time. Task load was notably lower in the experimental group across all TLX domains for error 3 and in 4 out of 5 domains for error 2 (P < .05). Experimental group members expressed increased confidence in troubleshooting in live patient settings if provided with the RMC. Conclusions and relevance ARMC reduced the time to resolve robotic errors and decreased stress load on surgeons. These promising findings advocate for further evaluation and potential implementation of the RMC in live operative settings.
- 22 July 2025
- Published by Springer Nature in Surgical Endoscopy
- Vol. 39 (9) , 5820-5829
Robotic malfunction checklist: a guide to operating room safety, efficiency, and surgeon autonomy
Importance Surgical robots encounter malfunctions requiring swift resolution, impacting patient safety and surgical efficiency. A Robotic Malfunction Checklist (RMC) may enhance surgical team autonomy reduce stress and intraoperative downtime. Objective To assess the efficacy of a step-by-step RMC for troubleshooting surgical robot errors through a randomized controlled trial simulation. Design An IRB-approved study conducted a needs analysis to identify common robotic errors. A specialized RMC was then developed and tested in a randomized simulation setting, utilizing the da Vinci Xi system. Setting Simulation environment utilizing the da Vinci Xi surgical robot system. Participants Thirty-one participants, including surgery residents and attendings were allocated to either the control (n = 16) or experimental groups (n = 15). Interventions Control group participants addressed errors conventionally, while experimental group members utilized the RMC for troubleshooting. Main outcomes and measures Post-survey data, including NASA Task Load Index (TLX) scores were collected to assess task load and confidence in troubleshooting. Statistical analysis involved the Mann–Whitney U test and Fischer's exact test. Results The experimental group significantly expedited resolution of the third complex error (3.9 min; IQR = 5.2; P < 0.01), representing a 43% reduction in resolution time. Task load was notably lower in the experimental group across all TLX domains for error 3 and in 4 out of 5 domains for error 2 (P < .05). Experimental group members expressed increased confidence in troubleshooting in live patient settings if provided with the RMC. Conclusions and relevance ARMC reduced the time to resolve robotic errors and decreased stress load on surgeons. These promising findings advocate for further evaluation and potential implementation of the RMC in live operative settings.
- 28 November 2024
- Published by Elsevier in The American Journal of Surgery
- Vol. 240, 116121
Trauma video review analysis: Increased provider movement impedes trauma team performance
- 28 November 2024
- Published by Elsevier in The American Journal of Surgery
- Vol. 240, 116121
Trauma video review analysis: Increased provider movement impedes trauma team performance
- 24 June 2023
- Published by Elsevier in Journal of Surgical Education
- Vol. 80 (8) , 1056-1060
A Call for Formalized Training of Surgical Educators
- 24 June 2023
- Published by Elsevier in Journal of Surgical Education
- Vol. 80 (8) , 1056-1060
A Call for Formalized Training of Surgical Educators