Inge Fourneau
Research Subjects
Inge Fourneau has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
A. Nevelsteen
Center for Vascular Diseases, University Hospital Gasthuisberg
5 shared publicationsK. Daenens
Center for Vascular Diseases, University Hospital Gasthuisberg
5 shared publicationsG. Maleux
Center for Vascular Diseases, University Hospital Gasthuisberg
2 shared publicationsKim Daenens
2 shared publications- A. Nevelsteen
Center for Vascular Diseases, University Hospital Gasthuisberg, Leuven, Belgium
1 shared publication Andre Nevelsteen
1 shared publication
Latest Publications
- 1 March 2009
- Published by Elsevier in Annals of Vascular Surgery
- Vol. 23 (2) , 179-185
The Role of Thrombolysis in Acute Infrainguinal Bypass Occlusion: A Prospective Nonrandomized Controlled Study
- 1 March 2009
- Published by Elsevier in Annals of Vascular Surgery
- Vol. 23 (2) , 179-185
The Role of Thrombolysis in Acute Infrainguinal Bypass Occlusion: A Prospective Nonrandomized Controlled Study
- 1 January 2007
- Published by Taylor & Francis in Acta Chirurgica Belgica
- Vol. 107 (3) , 325-327
Chronic Contained Rupture of an Abdominal Aortic Aneurysm Presenting as a Grynfeltt Lumbar Hernia. A Case Report
We report a unique case of chronic contained thoraco-abdominal aneurysm rupture presenting as a Grynfeltt lumbar hernia. A 79-year-old man presented with backpain and a bluish swelling in the left lumbar region in the presence of a non tender aortic aneurysm. CT scan confirmed contained rupture of a type IV thoraco-abdominal aortic aneurysm. The peri-aortic haematoma protruded through the lumbar wall causing a Grynfeltt lumbar hernia. The aneurysm was replaced through a thoraco-phreno-lumbotomy. The patient survived and is doing well six months post-operatively.
- 1 January 2007
- Published by Taylor & Francis in Acta Chirurgica Belgica
- Vol. 107 (3) , 325-327
Chronic Contained Rupture of an Abdominal Aortic Aneurysm Presenting as a Grynfeltt Lumbar Hernia. A Case Report
We report a unique case of chronic contained thoraco-abdominal aneurysm rupture presenting as a Grynfeltt lumbar hernia. A 79-year-old man presented with backpain and a bluish swelling in the left lumbar region in the presence of a non tender aortic aneurysm. CT scan confirmed contained rupture of a type IV thoraco-abdominal aortic aneurysm. The peri-aortic haematoma protruded through the lumbar wall causing a Grynfeltt lumbar hernia. The aneurysm was replaced through a thoraco-phreno-lumbotomy. The patient survived and is doing well six months post-operatively.
- 1 November 2005
- Published by Elsevier in European Journal of Vascular and Endovascular Surgery
- Vol. 30 (5) , 489-493
Hand-assisted Laparoscopic Aortobifemoral Bypass for Occlusive Disease. Early and Mid-term Results
- 1 November 2005
- Published by Elsevier in European Journal of Vascular and Endovascular Surgery
- Vol. 30 (5) , 489-493
Hand-assisted Laparoscopic Aortobifemoral Bypass for Occlusive Disease. Early and Mid-term Results
- 1 January 2005
- Published by Taylor & Francis in Acta Chirurgica Belgica
- Vol. 105 (2) , 194-197
Endovascular Stent-Graft and First Rib Resection for Thoracic Outlet Syndrome Complicated by an Aneurysm of the Subclavian Artery
Purpose: To report our experience with a combined endovascular and surgical approach for arterial thoracic outlet syndrome (TOS) complicated by an aneurysm of the subclavian artery. Methods: We treated three consecutive patients suffering from arterial thoracic outlet syndrome complicated by an aneurysm of the subclavian artery by the use of a stent-graft and a first rib resection. These patients were reviewed retrospectively. Results: At a mean follow-up of 37.3 months all patients were free of symptoms without late complications. Conclusions: Endovascular stent-grafting followed by decompression of the costoclavicular space is an attractive alternative to the conventional surgical approach of complicated arterial TOS.
- 1 January 2005
- Published by Taylor & Francis in Acta Chirurgica Belgica
- Vol. 105 (2) , 194-197
Endovascular Stent-Graft and First Rib Resection for Thoracic Outlet Syndrome Complicated by an Aneurysm of the Subclavian Artery
Purpose: To report our experience with a combined endovascular and surgical approach for arterial thoracic outlet syndrome (TOS) complicated by an aneurysm of the subclavian artery. Methods: We treated three consecutive patients suffering from arterial thoracic outlet syndrome complicated by an aneurysm of the subclavian artery by the use of a stent-graft and a first rib resection. These patients were reviewed retrospectively. Results: At a mean follow-up of 37.3 months all patients were free of symptoms without late complications. Conclusions: Endovascular stent-grafting followed by decompression of the costoclavicular space is an attractive alternative to the conventional surgical approach of complicated arterial TOS.
- 1 January 2004
- Published by Taylor & Francis in Acta Chirurgica Belgica
- Vol. 104 (5) , 499-504
Minimal—Access Aortic Surgery: The Potentials of Hand—Assisted Laparoscopy
In analogy with the good results of laparoscopic abdominal procedures minimal-access aortic surgery looks very promising. However, in spite of the many technical improvements that have already been made, totally laparo-scopic and even laparoscopically assisted aortic surgery remains technically demanding. This explains the rather slow introduction of minimal-access aortic surgery in the vascular society. In anticipation of increasing surgical experience and better instrumentation that will make the technique feasible for each vascular surgeon, hand-assisted laparoscopy (HALS) can be a valuable intermediate approach. HALS offers an easy to perform and still clearly less invasive approach for all aorto-iliac reconstructions.
- 1 January 2004
- Published by Taylor & Francis in Acta Chirurgica Belgica
- Vol. 104 (5) , 499-504
Minimal—Access Aortic Surgery: The Potentials of Hand—Assisted Laparoscopy
In analogy with the good results of laparoscopic abdominal procedures minimal-access aortic surgery looks very promising. However, in spite of the many technical improvements that have already been made, totally laparo-scopic and even laparoscopically assisted aortic surgery remains technically demanding. This explains the rather slow introduction of minimal-access aortic surgery in the vascular society. In anticipation of increasing surgical experience and better instrumentation that will make the technique feasible for each vascular surgeon, hand-assisted laparoscopy (HALS) can be a valuable intermediate approach. HALS offers an easy to perform and still clearly less invasive approach for all aorto-iliac reconstructions.
- 1 August 2003
- Published by SAGE Publications in Journal of Endovascular Therapy
- Vol. 10 (4) , 843-845
Endoprosthetic Treatment of a Mycotic Superficial Femoral Artery Aneurysm
To describe the successful stent-graft exclusion of a mycotic aneurysm of the superficial femoral artery. A 78-year-old man presented with Salmonella arteritis and the formation of a mycotic false aneurysm of the superficial femoral artery. Antibiotics were administered; the aneurysm was excluded using 2 Hemobahn stent-grafts, and the surrounding hematoma was drained. One year postoperatively, there are no clinical or biochemical signs of infection. Ultrasound examination does not show any fluid around the patent stent-graft. Stent-graft placement might be an alternative to traditional surgery in selected cases of mycotic aneurysm.
- 1 August 2003
- Published by SAGE Publications in Journal of Endovascular Therapy
- Vol. 10 (4) , 843-845
Endoprosthetic Treatment of a Mycotic Superficial Femoral Artery Aneurysm
To describe the successful stent-graft exclusion of a mycotic aneurysm of the superficial femoral artery. A 78-year-old man presented with Salmonella arteritis and the formation of a mycotic false aneurysm of the superficial femoral artery. Antibiotics were administered; the aneurysm was excluded using 2 Hemobahn stent-grafts, and the surrounding hematoma was drained. One year postoperatively, there are no clinical or biochemical signs of infection. Ultrasound examination does not show any fluid around the patent stent-graft. Stent-graft placement might be an alternative to traditional surgery in selected cases of mycotic aneurysm.
- 1 January 2003
- Vol. 9 (4) , 75-8
[Renal artery angioplasty: current status].
- Open Access
- 1 October 2000
- Published by American Medical Association (AMA) in Archives of Surgery
- Vol. 135 (10) , 1183-1189
An Improved Model of Acute Liver Failure Based on Transient Ischemia of the Liver
DESPITE intensive medical treatment, the mortality of acute liver failure (ALF) is high. With the introduction of orthotopic liver transplantation, 1-year survival increased to 80%.1 However, liver transplantation is hampered by a severe shortage of donor organs. This limited availability of donor organs has led to a new impetus for the development of liver-supporting systems, ie, bioartificial liver, to prevent the patient from dying while waiting for liver transplantation or even to avoid transplantation if regeneration can be secured. Although various bioartificial liver-supporting systems have already been introduced in clinical trials, evaluation of the safety, efficacy, and mechanism of action of liver-assist devices would be greatly facilitated if they could be tested in a clinically relevant large animal model. Extensive research has been conducted to develop a suitable animal model of ALF. Terblanche et al2 evaluated the various animal models of ALF in 1974 and updated their findings 15 years later.3 According to their findings, 6 criteria are required for a "satisfactory" animal model: reversibility, reproducibility, death from liver failure, sufficient therapeutic window, large animal model, and minimal hazard to personnel. We believe that a seventh requirement should be added: liver failure should be induced in a conscious animal without influence of anesthetics or sedation to be able to evaluate the development of encephalopathy, since it is an essential part of the clinical features of ALF.
- 1 October 2000
- Published by American Medical Association (AMA) in Archives of Surgery
- Vol. 135 (10) , 1183-1189
Open AccessAn Improved Model of Acute Liver Failure Based on Transient Ischemia of the Liver
DESPITE intensive medical treatment, the mortality of acute liver failure (ALF) is high. With the introduction of orthotopic liver transplantation, 1-year survival increased to 80%.1 However, liver transplantation is hampered by a severe shortage of donor organs. This limited availability of donor organs has led to a new impetus for the development of liver-supporting systems, ie, bioartificial liver, to prevent the patient from dying while waiting for liver transplantation or even to avoid transplantation if regeneration can be secured. Although various bioartificial liver-supporting systems have already been introduced in clinical trials, evaluation of the safety, efficacy, and mechanism of action of liver-assist devices would be greatly facilitated if they could be tested in a clinically relevant large animal model. Extensive research has been conducted to develop a suitable animal model of ALF. Terblanche et al2 evaluated the various animal models of ALF in 1974 and updated their findings 15 years later.3 According to their findings, 6 criteria are required for a "satisfactory" animal model: reversibility, reproducibility, death from liver failure, sufficient therapeutic window, large animal model, and minimal hazard to personnel. We believe that a seventh requirement should be added: liver failure should be induced in a conscious animal without influence of anesthetics or sedation to be able to evaluate the development of encephalopathy, since it is an essential part of the clinical features of ALF.