Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yang Zhang has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Seismic Response Characteristics of a Utility Tunnel Crossing a River Considering Hydrodynamic Pressure Effects

    by Yuanhong Wang, Yang Zhang, Ziyuan Huang, Konghao Wang, Aiping Tang

    As a long lifeline system of buried structures, the utility tunnel (UT) is vulnerable to earthquake invasion. For utility tunnels with inverted siphon arrangements crossing rivers, the seismic response is more complex due to the basin effect of acceleration in the topography and the influence of fluctuating hydrodynamic pressure, but there is currently a gap in targeted seismic response analyses and references. Based on a UT project in Haikou, this paper studied seismic responses of a cast-in-place UT considering the coupled model of water–soil–tunnel structure on ABAQUS software. Herein, the dynamic fluctuation of hydrodynamic pressure is simulated using an acoustic–solid interaction model. A viscoelastic artificial boundary was used to simulate the soil boundary effect, and seismic loads were equivalent to nodal forces. Considering seismic invading direction and varying water elevation, this paper investigates the dynamic response characteristics and damage mechanisms of river-crossing utility tunnels. This study shows that the basin effect causes the soil acceleration around the UT to show variability in different sections, and the amplification factor of the peak acceleration at the central location is almost doubled. The damage and dynamic water pressure of the UT are intensified under bidirectional seismic excitation, and the damage location is concentrated at the junction of the horizontal section and the vertical section. Bending moments and axial forces are the main mechanical behaviors along the axial direction. Changes in river levels have a certain positive effect on the UT peak MISES, DAMAGEC, and SDEG, and it exhibits a certain degree of energy dissipation and seismic damping effect. For the aseismic design of cross-river cast-in-place utility tunnels, bidirectional seismic calculations should be performed, and the influence of river hydrodynamic pressure should not be neglected.


  • Open Access

    Compressive Bearing Capacity and Ductility of Slurry-Infiltrated Fiber Concrete Blocks with Two-Dimensional Distributed Steel Fibers

    by Zhihao Wang, Yang Zhang, Lihua Huang, Hongbo Gao

    Slurry-infiltrated fiber concrete (SIFCON) has excellent potential for application as a new material with good crack resistance, impact resistance, and seismic performance. In this paper, SIFCON blocks were cast in a single pour using the custom-made two-dimensional directional steel fiber placement device, followed by compressive testing. Based on the test results, the effects of fly ash substitution rate, steel fiber aspect ratio, and steel fiber volume fraction on the compressive bearing capacity and ductility of SIFCON blocks were investigated. The results indicate that the custom-made device in this paper effectively achieves the directional placement of steel fibers, offering a cost-effective solution that optimizes the construction process. Regarding the test results, it was observed that the compressive bearing capacity of SIFCON blocks decreases linearly with increasing fly ash substitution rate, while the addition of fly ash improves the ductility of the blocks. Notably, a 31% decrease in bearing capacity was noted when the fly ash substitution rate increases from 0% to 40%, whereas the ductility ratio increased by 99% for the same substitution rate range. Furthermore, the results revealed a positive correlation between the bearing capacity and ductility of SIFCON blocks with higher steel fiber aspect ratios and volume fractions. Specifically, the bearing capacity increased by 19% and 33% with steel fiber aspect ratio increments from 33 to 70 and volume fraction increases from 10% to 14%, respectively. Additionally, the ductility ratio of the test blocks increased by 104% when the aspect ratio of the steel fibers increased from 33 to 70, and by 37% when the volume fraction of steel fibers rose from 10% to 14%.


  • Open Access

    Experimental Study on the Structural Performance of Reinforced Truss Concrete Composite Slabs during and after Fire

    by Bing Li, Zhengshang Li, Zhijun Chen, Zhoulin Yang, Yang Zhang

    Standard fire resistance tests and post-fire tests on residual mechanical properties were carried out on two four-edge simply supported reinforced truss concrete two-way composite slabs with wide seam splicing (“integral seam”) and close seam splicing (“separated seam”), and the effects of the different splicing forms on the mechanical properties of the reinforced truss concrete composite slabs during and after exposure to high temperatures were explored. The results indicate that there are significant differences in terms of crack developments, moisture loss times on the slab surface, spalling characteristics of the bottom of the slab and cross-section temperature gradients of concrete and steel reinforcement along the thickness direction between the wide seam spliced reinforced truss concrete composite two-way slab (referred to as “S1 composite slab”) and the close seam spliced reinforced truss concrete composite two-way slab (referred to as “S2 composite slab”) in the fire test. This is mainly due to differences in the splicing forms and structural measures of the prefabricated base slabs at joints, which led to changes in the heat transfer path at the joints. As the temperature at the close seam can be released quickly, the stiffness recovery of the S2 composite slab is significantly greater than the stiffness weakening due to the thermal hysteresis of the concrete, so the deflection of the S2 composite slab recovers immediately after the fire stops. Overall, both the S1 and S2 composite slabs exhibit two-way high temperature deformation characteristics. The post-fire residual static load tests show that the static load-carrying capacity of the S1 composite slab is 12.08% higher than that of the S2 composite slab and the ultimate displacement is 8.74% lower than that of the S2 composite slab. It is appropriate to calculate the residual load capacities of the S1 and S2 composite slabs after the fire as a one-way slab.


  • Open Access

    Study on the Compressive Stress–Strain Curve and Performance of Low-Slump Polypropylene Fiber Concrete after High Temperature

    by Bing Li, Wenbin Zheng, Yang Zhang

    This study aims to investigate the effect of high temperature on the mechanical properties of low-slump polypropylene fiber (PPF) concrete, and tests the tensile and compressive properties of 204 groups of low-slump PPF concrete with eight different dosages and four different lengths at normal temperature and after high temperature. The results of the compressive test showed that PPF can significantly improve the mechanical properties of concrete after high temperature when the fiber content is small, and the compressive strength of low collapse polypropylene fiber concrete after high temperature showed a tendency to rise and then fall at the same temperature with an increase of the fiber admixture. When the fiber content was 0.5 kg/m3, the compressive strengths of 3 mm, 9 mm, 15 mm and 19 mm reached their maxima, which were 9.65%, 11.33%, 7.90% and 2.87% higher than that of ordinary concrete, respectively. With an increase in fiber length, the effect of PPF on the compressive strength of concrete is not obvious. PPF at high admixture further increases the pore and air content in concrete, which decreases the compactness of the concrete, thus leading to a decrease in the compressive strength of the concrete. When the temperature was 800 °C and the fiber admixture was 5.0 kg/m3, the compressive strength of PPF concrete with different lengths reduced by 17.83%, 17.27%, 22.59% and 23.92%, respectively, compared to normal concrete. In addition, according to the results, the optimal combinations of strength at room temperature and after high temperature were 3 mm fiber length and 1.0 kg/m3 dosing and 9 mm fiber length and 0.5 kg/m3 dosing, respectively, which increased the compressive and tensile strengths by 17.15% and 25.72% at room temperature and by at least 6% and 20% after high temperature, compared to the concrete without fiber dosing. Moreover, the stress–strain constitutive equations of PPF concrete at normal temperature and after high temperature were established, which can be used for finite element simulation and related mechanical analysis of PPF after high temperature.