Oliver Blaschke
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Oliver Blaschke has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Klaus Stefan Drese
Institute of Sensor and Actuator Technology, Coburg University of Applied Sciences and Arts, Am Hofbrauhaus 1b, 96450 Coburg, Germany
4 shared publications - Felix Brand
Institute of Sensor and Actuator Technology, Coburg University of Applied Sciences and Arts, Am Hofbrauhaus 1b, 96450 Coburg, Germany
2 shared publications - Alexandra Troi
Institute for Renewable Energy, EURAC Research, 39100 Bolzano, Italy
1 shared publication - Christoph Franzen
Institut für Diagnostik und Konservierung an Denkmalen in Sachsen und Sachsen-Anhalt e. V., Schloßplatz 1, 01067 Dresden, Germany
1 shared publication D. Bernhardt-Famulla
Dr. Küke GmbH Wedemark Germany
1 shared publication- Daniel Frenzel
Faculty of Design, Coburg University of Applied Sciences and Arts, Am Hofbräuhaus 1b, 96450 Coburg, Germany
1 shared publication
Latest Publications
- Open Access
- 1 January 2025
- Published by AMA Service GmbH
- p. 40-43
A4-a2 - Ultrasonic Guided Waves for Gas Bubble Removal on Optical Sensor Surfaces
This study demonstrates a method for gas bubble removal from glass surfaces using acoustic standing wave fields. Piezoelectric transducers generate targeted frequencies, creating radiation forces that move bubbles toward antinodes. By incorporating bubble resonance frequencies, detachment efficiency is enhanced. Simulations and experiments confirmed effective wave formation and bubble migration. A burst-mode excitation minimized thermal load, providing a non-invasive solution for maintaining optical sensor performance in liquid environments.
- 1 January 2025
- Published by AMA Service GmbH
- p. 40-43
Open AccessA4-a2 - Ultrasonic Guided Waves for Gas Bubble Removal on Optical Sensor Surfaces
This study demonstrates a method for gas bubble removal from glass surfaces using acoustic standing wave fields. Piezoelectric transducers generate targeted frequencies, creating radiation forces that move bubbles toward antinodes. By incorporating bubble resonance frequencies, detachment efficiency is enhanced. Simulations and experiments confirmed effective wave formation and bubble migration. A burst-mode excitation minimized thermal load, providing a non-invasive solution for maintaining optical sensor performance in liquid environments.
- Open Access
Improved EMAT Sensor Design for Enhanced Ultrasonic Signal Detection in Steel Wire Ropes
This study is focused on optimizing electromagnetic acoustic transducer (EMAT) sensors for enhanced ultrasonic guided wave signal generation in steel cables using CAD and modern manufacturing to enable contactless ultrasonic signal transmission and reception. A lab test rig with advanced measurement and data processing was set up to test the sensors’ ability to detect cable damage, like wire breaks and abrasion, while also examining the effect of potential disruptors such as rope soiling. Machine learning algorithms were applied to improve the damage detection accuracy, leading to significant advancements in magnetostrictive measurement methods and providing a new standard for future development in this area. The use of the Vision Transformer Masked Autoencoder Architecture (ViTMAE) and generative pre-training has shown that reliable damage detection is possible despite the considerable signal fluctuations caused by rope movement.
Open AccessImproved EMAT Sensor Design for Enhanced Ultrasonic Signal Detection in Steel Wire Ropes
This study is focused on optimizing electromagnetic acoustic transducer (EMAT) sensors for enhanced ultrasonic guided wave signal generation in steel cables using CAD and modern manufacturing to enable contactless ultrasonic signal transmission and reception. A lab test rig with advanced measurement and data processing was set up to test the sensors’ ability to detect cable damage, like wire breaks and abrasion, while also examining the effect of potential disruptors such as rope soiling. Machine learning algorithms were applied to improve the damage detection accuracy, leading to significant advancements in magnetostrictive measurement methods and providing a new standard for future development in this area. The use of the Vision Transformer Masked Autoencoder Architecture (ViTMAE) and generative pre-training has shown that reliable damage detection is possible despite the considerable signal fluctuations caused by rope movement.
- Open Access
- 29 October 2024
- Published by MDPI AG in Micromachines
- Vol. 15 (11) , 1312
Consistent Evaluation Methods for Microfluidic Mixers
The study presents a unifying methodology for characterizing micromixers, integrating both experimental and simulation techniques. Focusing on Dean mixer designs, it employs an optical evaluation for experiments and a modified Sobolev norm for simulations, yielding a unified dimensionless characteristic parameter for the whole mixer at a given Reynolds number. The results demonstrate consistent mixing performance trends across both methods for various operation points. This paper also proposes enhancements in the evaluation process to improve accuracy and reduce noise impact. This approach provides a valuable framework for optimizing micromixer designs, essential in advancing microfluidic technologies.
- 29 October 2024
- Published by MDPI AG in Micromachines
- Vol. 15 (11) , 1312
Open AccessConsistent Evaluation Methods for Microfluidic Mixers
The study presents a unifying methodology for characterizing micromixers, integrating both experimental and simulation techniques. Focusing on Dean mixer designs, it employs an optical evaluation for experiments and a modified Sobolev norm for simulations, yielding a unified dimensionless characteristic parameter for the whole mixer at a given Reynolds number. The results demonstrate consistent mixing performance trends across both methods for various operation points. This paper also proposes enhancements in the evaluation process to improve accuracy and reduce noise impact. This approach provides a valuable framework for optimizing micromixer designs, essential in advancing microfluidic technologies.
- Open Access
Quantification of Moisture in Masonry via AI-Evaluated Broadband Radar Reflectometry
Humidity, salt content, and migration in building materials lead to weathering and are a common challenge. To understand damage phenomena and select the right conservation treatments, knowledge on both the amount and distribution of moisture and salt load in the masonry is crucial. It was shown that commercial portable devices addressing moisture are often limited by the mutual interference of these values. This can be improved by exploiting broadband radar reflectometry for the quantification of humidity in historic masonry. Due to the above-mentioned limitations, today’s gold standard for evaluating the moisture content in historic buildings is still conducted by taking drilling samples with a subsequent evaluation in a specially designed laboratory, the so-called Darr method. In this paper, a new broadband frequency approach in the range between 0.4 and 6 GHz with improved artificial-intelligence data analysis makes sure to optimize the reflected signal, simplify the evaluation of the generated data, and minimise the effects of variables such as salt contamination that influence the permittivity. In this way, the amount of water could be determined independently from the salt content in the material and an estimate of the salt load. With new machine learning algorithms, the analysis of the permittivity is improved and can be made accessible for everyday use on building sites with minimal intervention by the user. These algorithms were trained with generated data from different drying studies on single building bricks from the masonries. The findings from the laboratory studies were then validated and evaluated on real historic buildings at real construction sites. Thus, the paper shows a spatially resolved and salt-independent measurement system for determining building moisture.
Open AccessQuantification of Moisture in Masonry via AI-Evaluated Broadband Radar Reflectometry
Humidity, salt content, and migration in building materials lead to weathering and are a common challenge. To understand damage phenomena and select the right conservation treatments, knowledge on both the amount and distribution of moisture and salt load in the masonry is crucial. It was shown that commercial portable devices addressing moisture are often limited by the mutual interference of these values. This can be improved by exploiting broadband radar reflectometry for the quantification of humidity in historic masonry. Due to the above-mentioned limitations, today’s gold standard for evaluating the moisture content in historic buildings is still conducted by taking drilling samples with a subsequent evaluation in a specially designed laboratory, the so-called Darr method. In this paper, a new broadband frequency approach in the range between 0.4 and 6 GHz with improved artificial-intelligence data analysis makes sure to optimize the reflected signal, simplify the evaluation of the generated data, and minimise the effects of variables such as salt contamination that influence the permittivity. In this way, the amount of water could be determined independently from the salt content in the material and an estimate of the salt load. With new machine learning algorithms, the analysis of the permittivity is improved and can be made accessible for everyday use on building sites with minimal intervention by the user. These algorithms were trained with generated data from different drying studies on single building bricks from the masonries. The findings from the laboratory studies were then validated and evaluated on real historic buildings at real construction sites. Thus, the paper shows a spatially resolved and salt-independent measurement system for determining building moisture.
- Open Access
Quantification of Humidity and Salt Detection in Historical Building Materials via Broadband Radar Measurement
For the investigation of moisture and salt content in historic masonry, destructive drilling samples followed by a gravimetric investigation is still the preferred method. In order to prevent the destructive intrusion into the building substance and to enable a large-area measurement, a nondestructive and easy-to-use measuring principle is needed. Previous systems for moisture measurement usually fail due to a strong dependence on contained salts. In this work, a ground penetrating radar (GPR) system was used to determine the frequency-dependent complex permittivity in the range between 1 and 3 GHz on salt-loaded samples of historical building materials. By choosing this frequency range, it was possible to determine the moisture in the samples independently of the salt content. In addition, it was possible to make a quantitative statement about the salt level. The applied method demonstrates that with ground penetrating radar measurements in the frequency range selected here, a salt-independent moisture determination can be carried out.
Open AccessQuantification of Humidity and Salt Detection in Historical Building Materials via Broadband Radar Measurement
For the investigation of moisture and salt content in historic masonry, destructive drilling samples followed by a gravimetric investigation is still the preferred method. In order to prevent the destructive intrusion into the building substance and to enable a large-area measurement, a nondestructive and easy-to-use measuring principle is needed. Previous systems for moisture measurement usually fail due to a strong dependence on contained salts. In this work, a ground penetrating radar (GPR) system was used to determine the frequency-dependent complex permittivity in the range between 1 and 3 GHz on salt-loaded samples of historical building materials. By choosing this frequency range, it was possible to determine the moisture in the samples independently of the salt content. In addition, it was possible to make a quantitative statement about the salt level. The applied method demonstrates that with ground penetrating radar measurements in the frequency range selected here, a salt-independent moisture determination can be carried out.