Jean-Christophe Leroux
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jean-Christophe Leroux has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
J. Taillefer
Faculty of Pharmacy, University of Montreal, Qc, Canada
3 shared publicationsN. Brasseur
MRC Group in the Radiation Sciences, Department of Nuclear Medicine and Radiobiology, Faculty of Medicine, University of Sherbrooke , Sherbrooke (Qc)
3 shared publicationsEmmanuelle Roux
Canada Research Chair in Drug Delivery, Faculty of Pharmacy, Université de Montréal, C.P. 6128 Succ. Centre-ville, Québec, Canada H3C 3J7
2 shared publicationsJ.E. van Lier
MRC Group in the Radiation Sciences, Department of Nuclear Medicine and Radiobiology, Faculty of Medicine, University of Sherbrooke, Sherbrooke, Quebec, Canada J1H 5N4
2 shared publicationsAbdellatif Chenite
BIOSYNTECH Limited, 475 Armand–Frappier Bd., Parc Scientifique et de Haute Technologie, Laval, Qc, H7V 4B3, Canada
1 shared publicationClaire Jarry
Faculty of Pharmacy, University of Montreal, C.P. 6128 succ. centre-ville, Montreal, Qc, H3C 3J7, Canada
1 shared publication
Latest Publications
- 1 August 2002
- Published by Elsevier in Journal of Pharmaceutical Sciences
- Vol. 91 (8) , 1795-1802
Steric stabilization of liposomes by pH‐responsive N‐isopropylacrylamide copolymer
- 1 August 2002
- Published by Elsevier in Journal of Pharmaceutical Sciences
- Vol. 91 (8) , 1795-1802
Steric stabilization of liposomes by pH‐responsive N‐isopropylacrylamide copolymer
- 1 May 2001
- Published by Elsevier in Journal of Controlled Release
- Vol. 72 (1-3) , 71-84
N-isopropylacrylamide copolymers for the preparation of pH-sensitive liposomes and polymeric micelles
- 1 May 2001
- Published by Elsevier in Journal of Controlled Release
- Vol. 72 (1-3) , 71-84
N-isopropylacrylamide copolymers for the preparation of pH-sensitive liposomes and polymeric micelles
- 1 February 2001
- Published by Oxford University Press (OUP) in Journal of Pharmacy and Pharmacology
- Vol. 53 (2) , 155-166
In-vitro and in-vivo evaluation of pH-responsive polymeric micelles in a photodynamic cancer therapy model
PH-sensitive polymeric micelles of randomly and terminally alkylated N-isopropylacrylamide copolymers were prepared and characterized. Aluminium chloride phthalocyanine (AlClPc), a second generation sensitizer for the photodynamic therapy of cancer, was incorporated in the micelles by dialysis. Their photodynamic activities were evaluated in-vitro against EMT-6 mouse mammary tumour cells and in-vivo against EMT-6 tumours implanted intradermally on each hind thigh of Balb/c mice. pH-sensitive polymeric micelles were found to exhibit greater cytotoxicity in-vitro than control Cremophor EL formulations. In the presence of chloroquine, a weak base that raises the internal pH of acidic organelles, in-vitro experiments demonstrated the importance of endosomal/lysosomal acidity for the pH-sensitive polymeric micelles to be fully effective. Biodistribution was assessed by fluorescence of tissue extracts after intravenous injection of 2 μmol kg−1 AlClPc. The results revealed accumulation of AlClPc polymeric micelles in the liver, spleen and lungs, with a lower tumour uptake than AlClPc Cremophor EL formulations. However, polymeric micelles exhibited similar activity in-vivo to the control Cremophor EL formulations, demonstrating the higher potency of AlClPc polymeric micelles when localized in tumour tissue. It was concluded that polymeric micelles represent a good alternative to Cremophor EL preparations for the vectorization of hydrophobic drugs.
- 1 February 2001
- Published by Oxford University Press (OUP) in Journal of Pharmacy and Pharmacology
- Vol. 53 (2) , 155-166
In-vitro and in-vivo evaluation of pH-responsive polymeric micelles in a photodynamic cancer therapy model
PH-sensitive polymeric micelles of randomly and terminally alkylated N-isopropylacrylamide copolymers were prepared and characterized. Aluminium chloride phthalocyanine (AlClPc), a second generation sensitizer for the photodynamic therapy of cancer, was incorporated in the micelles by dialysis. Their photodynamic activities were evaluated in-vitro against EMT-6 mouse mammary tumour cells and in-vivo against EMT-6 tumours implanted intradermally on each hind thigh of Balb/c mice. pH-sensitive polymeric micelles were found to exhibit greater cytotoxicity in-vitro than control Cremophor EL formulations. In the presence of chloroquine, a weak base that raises the internal pH of acidic organelles, in-vitro experiments demonstrated the importance of endosomal/lysosomal acidity for the pH-sensitive polymeric micelles to be fully effective. Biodistribution was assessed by fluorescence of tissue extracts after intravenous injection of 2 μmol kg−1 AlClPc. The results revealed accumulation of AlClPc polymeric micelles in the liver, spleen and lungs, with a lower tumour uptake than AlClPc Cremophor EL formulations. However, polymeric micelles exhibited similar activity in-vivo to the control Cremophor EL formulations, demonstrating the higher potency of AlClPc polymeric micelles when localized in tumour tissue. It was concluded that polymeric micelles represent a good alternative to Cremophor EL preparations for the vectorization of hydrophobic drugs.
- 1 January 2001
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 58 (1) , 127-135
Effects of steam sterilization on thermogelling chitosan-based gels
A new thermogelling chitosan‐glycerophosphate system has been recently proposed for biomedical applications such as drug and cell delivery. The objectives of this work were to characterize the effect of steam sterilization on the in vitro and in vivo end performances of the gel and to develop a filtration‐based method to assess its sterility. Autoclaving 2% (w/v) chitosan solutions for as short as 10 min resulted in a 30% decrease in molecular weight, 3–5‐fold decrease in dynamic viscosity, and substantial loss of mechanical properties of the resulting gel. However, sterilization did not impair the ability of the system to form a gel at 37°C. The antimicrobial activity of chitosan against several microorganisms was evaluated after inoculation of chitosan solutions and removal of the cells by filtration. It was found that, although chitosan was bacteriostatic against the heat sterilization bioindicator Bacillus stearothermophilus, the bacteria could rapidly grow after separation from the chitosan solution by filtration. This indicated that B. stearothermophilus is an adequate strain to validate a heat sterilization method on chitosan preparations, and accordingly this strain was used to assess the sterility of chitosan solution following a 10 min autoclaving time. © 2001 John Wiley & Sons, Inc. J Biomed Mater Res (Appl Biomater) 58: 127–135, 2001
- 1 January 2001
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 58 (1) , 127-135
Effects of steam sterilization on thermogelling chitosan-based gels
A new thermogelling chitosan‐glycerophosphate system has been recently proposed for biomedical applications such as drug and cell delivery. The objectives of this work were to characterize the effect of steam sterilization on the in vitro and in vivo end performances of the gel and to develop a filtration‐based method to assess its sterility. Autoclaving 2% (w/v) chitosan solutions for as short as 10 min resulted in a 30% decrease in molecular weight, 3–5‐fold decrease in dynamic viscosity, and substantial loss of mechanical properties of the resulting gel. However, sterilization did not impair the ability of the system to form a gel at 37°C. The antimicrobial activity of chitosan against several microorganisms was evaluated after inoculation of chitosan solutions and removal of the cells by filtration. It was found that, although chitosan was bacteriostatic against the heat sterilization bioindicator Bacillus stearothermophilus, the bacteria could rapidly grow after separation from the chitosan solution by filtration. This indicated that B. stearothermophilus is an adequate strain to validate a heat sterilization method on chitosan preparations, and accordingly this strain was used to assess the sterility of chitosan solution following a 10 min autoclaving time. © 2001 John Wiley & Sons, Inc. J Biomed Mater Res (Appl Biomater) 58: 127–135, 2001
- 1 January 2000
- Published by Elsevier in Journal of Pharmaceutical Sciences
- Vol. 89 (1) , 52-62
Preparation and Characterization of pH-Responsive Polymeric Micelles for the Delivery of Photosensitizing Anticancer Drugs
- 1 January 2000
- Published by Elsevier in Journal of Pharmaceutical Sciences
- Vol. 89 (1) , 52-62
Preparation and Characterization of pH-Responsive Polymeric Micelles for the Delivery of Photosensitizing Anticancer Drugs
- 1 January 2000
- Published by Elsevier in Journal of Pharmaceutical Sciences
- Vol. 89 (1) , 52-62
Preparation and Characterization of pH-Responsive Polymeric Micelles for the Delivery of Photosensitizing Anticancer Drugs
- 1 January 2000
- Published by Elsevier in Journal of Pharmaceutical Sciences
- Vol. 89 (1) , 52-62
Preparation and Characterization of pH-Responsive Polymeric Micelles for the Delivery of Photosensitizing Anticancer Drugs