Erik H. Larsen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Erik H. Larsen has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Sven Moesgaard
Pharma Nord Research Department, 30-32 Sadelmagervej, DK-7100 Vejle, Denmark
3 shared publications- Jens Jørgen Sloth
Technical University of Denmark
2 shared publications Marianne Hansen
Danish Institute for Food and Veterinary Research, Department of Food Chemistry, 19 Mørkhøj Bygade, DK-2860 Søborg, Denmark
2 shared publicationsA. Møller
1 shared publication- Annette Petersen
National Food Institute, Technical University of Denmark, Mørkhøj Bygade 19, 2860, Søborg, Denmark
1 shared publication G. K. Mortensen
1 shared publication
Latest Publications
- Open Access
- 1 January 2004
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 87 (1) , 225-232
Speciation and Bioavailability of Selenium in Yeast-Based Intervention Agents Used in Cancer Chemoprevention Studies
This study investigated the speciation and bioavailability of selenium in yeast-based intervention agents from multiple manufacturers from several time points. Sources of selenized yeast included Nutrition 21 (San Diego, CA), which supplied the Nutritional Prevention of Cancer (NPC) Trial from 1981–1996; Cypress Systems (Fresno, CA; 1997–1999); and Pharma Nord (Vejle, Denmark; 1999–2000), which supplied the Prevention of Cancer by Intervention by Selenium (PRECISE) Trial pilot studies. The low-molecular-selenium species were liberated from the samples by proteolytic hydrolysis followed by separation by ion exchange liquid chromatography and detection by inductively coupled plasma-mass spectrometry. The results for the NPC tablets showed that selenomethionine, together with 3 unidentified selenium compounds, were predominant in the sample hydrolysates. The relative amounts of the 4 selenium species varied (p < 0.05) among several of the 7 tablet batches used during the course of the NPC Trial. In comparison, 5 batches of more recently produced selenized yeasts, which were used as a source of selenium in the PRECISE and other trials, contained less of the unknown compounds and more selenomethionine at 54–60% of the total selenium in the yeasts. One batch of yeast, however (from 1985), which originated from the same producer as the yeast used in the NPC tablets, contained only 27% of selenium in the sample as selenomethionine. Human subjects receiving 200 μg selenium/day in the UK PRECISE Pilot Trial showed a higher concentration (p < 0.01) and higher increase from baseline in plasma selenium than did the same dosage used in the NPC Trial. Differences in intake, speciation, or bioavailability of selenium from the yeast-based supplements in the population groups studied may explain this. Furthermore, the selenium concentration in whole blood from the Danish PRECISE Pilot Trial was higher (p < 0.001) than that obtained with synthetic L-selenomethionine in a comparable group of Danes, both groups having been treated with 300 μg selenium/day.
- 1 January 2004
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 87 (1) , 225-232
Open AccessSpeciation and Bioavailability of Selenium in Yeast-Based Intervention Agents Used in Cancer Chemoprevention Studies
This study investigated the speciation and bioavailability of selenium in yeast-based intervention agents from multiple manufacturers from several time points. Sources of selenized yeast included Nutrition 21 (San Diego, CA), which supplied the Nutritional Prevention of Cancer (NPC) Trial from 1981–1996; Cypress Systems (Fresno, CA; 1997–1999); and Pharma Nord (Vejle, Denmark; 1999–2000), which supplied the Prevention of Cancer by Intervention by Selenium (PRECISE) Trial pilot studies. The low-molecular-selenium species were liberated from the samples by proteolytic hydrolysis followed by separation by ion exchange liquid chromatography and detection by inductively coupled plasma-mass spectrometry. The results for the NPC tablets showed that selenomethionine, together with 3 unidentified selenium compounds, were predominant in the sample hydrolysates. The relative amounts of the 4 selenium species varied (p < 0.05) among several of the 7 tablet batches used during the course of the NPC Trial. In comparison, 5 batches of more recently produced selenized yeasts, which were used as a source of selenium in the PRECISE and other trials, contained less of the unknown compounds and more selenomethionine at 54–60% of the total selenium in the yeasts. One batch of yeast, however (from 1985), which originated from the same producer as the yeast used in the NPC tablets, contained only 27% of selenium in the sample as selenomethionine. Human subjects receiving 200 μg selenium/day in the UK PRECISE Pilot Trial showed a higher concentration (p < 0.01) and higher increase from baseline in plasma selenium than did the same dosage used in the NPC Trial. Differences in intake, speciation, or bioavailability of selenium from the yeast-based supplements in the population groups studied may explain this. Furthermore, the selenium concentration in whole blood from the Danish PRECISE Pilot Trial was higher (p < 0.001) than that obtained with synthetic L-selenomethionine in a comparable group of Danes, both groups having been treated with 300 μg selenium/day.
- 18 March 2003
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 18 (4) , 310-316
Selenium speciation and isotope composition in 77Se-enriched yeast using gradient elution HPLC separation and ICP-dynamic reaction cell-MS
A batch of 77Se-labelled and enriched yeast was characterised with regard to isotopic composition and content of selenium species for later use in a human absorption study based on the method of enriched stable isotopes. The abundance of the six stable selenium isotopes was determined by ICP-MS equipped with a dynamic reaction cell (DRC). The results showed that the 77Se isotope was enriched to 98.5 atom-%, whereas the remaining selenium was present as the other five isotopes at low abundance. The low-molecular 77Se containing species, which were biosynthesised by the yeast during fermentation using the enriched 77Se-selenite as substrate, were released by enzymatic hydrolysis using (I), a β-glucosidase followed by a protease mixture, and (II), a commercial protease preparation. For selenium speciation the chromatographic selectivity of the cation exchange HPLC system was adjusted to the separation of over 30 selenium species occurring in the hydrolysates by applying gradient elution using pyridinium formate as mobile phase. The quantitative results obtained by detection with ICP-DRC-MS of 77Se and 80Se showed that both enzymatic sample preparation systems released 90–95% of the yeast's selenium content. The total area of the cation exchange chromatograms, however, amounted to 64% of the total selenium content in the yeast, which was 1390 µg g−1. In the enzymatic extracts selenomethionine (SeMet) constituted 82% of all separated and quantified selenium species, which was equivalent to 53% of the total selenium content in the yeast. Oxidation of SeMet to selenomethionine-Se-oxide (SeOMet) occurred during sample preparation. The degree of formation of SeOMet was large and variable when using enzyme system I, but low when using enzyme II.
- 18 March 2003
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 18 (4) , 310-316
Selenium speciation and isotope composition in 77Se-enriched yeast using gradient elution HPLC separation and ICP-dynamic reaction cell-MS
A batch of 77Se-labelled and enriched yeast was characterised with regard to isotopic composition and content of selenium species for later use in a human absorption study based on the method of enriched stable isotopes. The abundance of the six stable selenium isotopes was determined by ICP-MS equipped with a dynamic reaction cell (DRC). The results showed that the 77Se isotope was enriched to 98.5 atom-%, whereas the remaining selenium was present as the other five isotopes at low abundance. The low-molecular 77Se containing species, which were biosynthesised by the yeast during fermentation using the enriched 77Se-selenite as substrate, were released by enzymatic hydrolysis using (I), a β-glucosidase followed by a protease mixture, and (II), a commercial protease preparation. For selenium speciation the chromatographic selectivity of the cation exchange HPLC system was adjusted to the separation of over 30 selenium species occurring in the hydrolysates by applying gradient elution using pyridinium formate as mobile phase. The quantitative results obtained by detection with ICP-DRC-MS of 77Se and 80Se showed that both enzymatic sample preparation systems released 90–95% of the yeast's selenium content. The total area of the cation exchange chromatograms, however, amounted to 64% of the total selenium content in the yeast, which was 1390 µg g−1. In the enzymatic extracts selenomethionine (SeMet) constituted 82% of all separated and quantified selenium species, which was equivalent to 53% of the total selenium content in the yeast. Oxidation of SeMet to selenomethionine-Se-oxide (SeOMet) occurred during sample preparation. The degree of formation of SeOMet was large and variable when using enzyme system I, but low when using enzyme II.
- 18 March 2003
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 18 (4) , 317-322
Determination of total selenium and 77Se in isotopically enriched human samples by ICP-dynamic reaction cell-MS
This paper describes an analytical method for the simultaneous quantitative determination of total selenium (Se) and 77Se in isotopically enriched human plasma, urine and faeces by inductively coupled plasma-dynamic reaction cell-mass spectrometry (ICP-DRC-MS). The samples originated from a human study in which a single dose of 327 µg 77Se (99.3% pure) had been given as intrinsically 77Se-labelled yeast, following administration for six weeks of 300 µg d−1 of selenium also as selenised yeast with natural isotope abundance. Prior to analysis, the plasma and urine samples and the digested faecal samples were diluted using an aqueous diluent containing 0.5% Triton X-100, 2% nitric acid and 3% methanol. Selenium was detected as 76Se, 77Se and 80Se by ICP-DRC-MS. Selenium originating from the natural isotope abundance yeast and other selenium sources from the diet was determined as 80Se, which was unaffected by the isotope enrichment. The degree of enrichment of 77Se was estimated from the measured 77Se signal intensity (natural abundance plus enrichment) minus the natural abundance of this isotope, which was calculated from measurement of 76Se. Quantification of the enriched amount of selenium 77Se was carried out against standard additions calibration curves (natural isotope abundance) by correcting the slope of the 77Se calibration curve according to the 99.3% abundance of this isotope in the enriched fraction. The limits of detection for selenium with natural abundance were 0.1 µg l−1, 0.2 µg l−1 and 6 µg kg−1 and the minimum detectable increase in 77Se was 0.38 µg l−1, 0.58 µg l−1 and 15 µg kg−1 (corresponding to 0.21%, 0.63% and 0.61% of the mean total selenium concentrations in this study) in plasma, urine and faeces, respectively. The accuracy was controlled by analysis of the reference materials Seronorm Serum and BCR 185 Bovine Liver.
- 18 March 2003
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 18 (4) , 317-322
Determination of total selenium and 77Se in isotopically enriched human samples by ICP-dynamic reaction cell-MS
This paper describes an analytical method for the simultaneous quantitative determination of total selenium (Se) and 77Se in isotopically enriched human plasma, urine and faeces by inductively coupled plasma-dynamic reaction cell-mass spectrometry (ICP-DRC-MS). The samples originated from a human study in which a single dose of 327 µg 77Se (99.3% pure) had been given as intrinsically 77Se-labelled yeast, following administration for six weeks of 300 µg d−1 of selenium also as selenised yeast with natural isotope abundance. Prior to analysis, the plasma and urine samples and the digested faecal samples were diluted using an aqueous diluent containing 0.5% Triton X-100, 2% nitric acid and 3% methanol. Selenium was detected as 76Se, 77Se and 80Se by ICP-DRC-MS. Selenium originating from the natural isotope abundance yeast and other selenium sources from the diet was determined as 80Se, which was unaffected by the isotope enrichment. The degree of enrichment of 77Se was estimated from the measured 77Se signal intensity (natural abundance plus enrichment) minus the natural abundance of this isotope, which was calculated from measurement of 76Se. Quantification of the enriched amount of selenium 77Se was carried out against standard additions calibration curves (natural isotope abundance) by correcting the slope of the 77Se calibration curve according to the 99.3% abundance of this isotope in the enriched fraction. The limits of detection for selenium with natural abundance were 0.1 µg l−1, 0.2 µg l−1 and 6 µg kg−1 and the minimum detectable increase in 77Se was 0.38 µg l−1, 0.58 µg l−1 and 15 µg kg−1 (corresponding to 0.21%, 0.63% and 0.61% of the mean total selenium concentrations in this study) in plasma, urine and faeces, respectively. The accuracy was controlled by analysis of the reference materials Seronorm Serum and BCR 185 Bovine Liver.
- 1 January 2002
- Published by Taylor & Francis in Food Additives & Contaminants
- Vol. 19 (1) , 33-46
Monitoring the content and intake of trace elements from food in Denmark
The content of cadmium, lead, nickel, mercury and selenium in 83 foods was monitored from 1993 to 1997. In comparison with similar results from 1988 to 1992, a general decrease in lead levels had occurred, whereas the contents of cadmium, nickel, mercury and selenium were stable or declined only slightly. The distribution in dietary intake of the five trace elements was estimated by combining the mean trace element concentrations with food consumption data from 1837 Danes aged 15–80 years. The lead intake for 1993–97 showed a decrease in comparison with similar estimates from the previous monitoring cycles: 1983–87 and 1988–92. The intake of cadmium and mercury decreased to a lesser extent, whereas the intake of selenium and nickel remained unchanged in the same period. The dietary intake of trace elements was compared with the provisional tolerable weekly intake (PTWI). The 95th percentile of the distribution in cadmium intake amounts to 34% of PTWI, which is relatively high, and therefore calls for a more detailed future risk assessment. The intakes of lead and mercury were 11% of PTWI and, like the intake of nickel, did not cause any health concern in the adult population. The Danes ingest close to 100% of the Nordic Nutrition Recommendation for selenium at 50 μg day-1, and no individuals had an intake less than the lower limit of 20 μg day-1.
- 1 January 2002
- Published by Taylor & Francis in Food Additives & Contaminants
- Vol. 19 (1) , 33-46
Monitoring the content and intake of trace elements from food in Denmark
The content of cadmium, lead, nickel, mercury and selenium in 83 foods was monitored from 1993 to 1997. In comparison with similar results from 1988 to 1992, a general decrease in lead levels had occurred, whereas the contents of cadmium, nickel, mercury and selenium were stable or declined only slightly. The distribution in dietary intake of the five trace elements was estimated by combining the mean trace element concentrations with food consumption data from 1837 Danes aged 15–80 years. The lead intake for 1993–97 showed a decrease in comparison with similar estimates from the previous monitoring cycles: 1983–87 and 1988–92. The intake of cadmium and mercury decreased to a lesser extent, whereas the intake of selenium and nickel remained unchanged in the same period. The dietary intake of trace elements was compared with the provisional tolerable weekly intake (PTWI). The 95th percentile of the distribution in cadmium intake amounts to 34% of PTWI, which is relatively high, and therefore calls for a more detailed future risk assessment. The intakes of lead and mercury were 11% of PTWI and, like the intake of nickel, did not cause any health concern in the adult population. The Danes ingest close to 100% of the Nordic Nutrition Recommendation for selenium at 50 μg day-1, and no individuals had an intake less than the lower limit of 20 μg day-1.
- 30 May 2000
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 15 (6) , 669-672
The application of inductively coupled plasma dynamic reaction cell mass spectrometry for measurement of selenium isotopes, isotope ratios and chromatographic detection of selenoamino acids
Inductively coupled plasma dynamic reaction cell mass spectrometry (ICP-DRC-MS) was characterised for the detection of the six naturally occurring selenium isotopes. The potentially interfering argon dimers at the selenium masses m/z 74, 76, 78 and 80 were reduced in intensity by approximately five orders of magnitude by using methane as reactive cell gas in the DRC. By using 3% v/v methanol in water for carbon-enhanced ionisation of selenium, the sensitivity of 80Se was 104 counts s−1 per ng ml−1 of selenium, and the estimated limit of detection was 6 pg ml−1. The precision of the isotope ratios was close to the theoretical values for selenium concentrations at 1 and 10 ng ml−1. The accuracy of the isotope ratios, however, was improved by correcting the count rate of all selenium isotopes equivalent to the formation of SeH at 9.6 ± 0.5% one mass unit above the selenium isotopes. A linear relationship (r < 0.98) was found between the error of the corrected isotope ratios and the difference in mass from the 80Se reference isotope. This indicated that the error was caused by mass bias. The slope of the curve at −3.0% error per mass unit can be used for correction of the measured ratios. Deuterated methane used as the DRC gas showed that hydrogen transfer from methane was not involved in the formation of SeH as SeD was absent in the mass spectrum. The almost interference-free detection of selenium by ICP-DRC-MS made the detection of the 80Se isotope possible for detection of selenoamino acids separated by cation exchange HPLC. The limit of detection of the HPLC-ICP-DRC-MS method was in the range 3–5 pg as selenium.
- 30 May 2000
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 15 (6) , 669-672
The application of inductively coupled plasma dynamic reaction cell mass spectrometry for measurement of selenium isotopes, isotope ratios and chromatographic detection of selenoamino acids
Inductively coupled plasma dynamic reaction cell mass spectrometry (ICP-DRC-MS) was characterised for the detection of the six naturally occurring selenium isotopes. The potentially interfering argon dimers at the selenium masses m/z 74, 76, 78 and 80 were reduced in intensity by approximately five orders of magnitude by using methane as reactive cell gas in the DRC. By using 3% v/v methanol in water for carbon-enhanced ionisation of selenium, the sensitivity of 80Se was 104 counts s−1 per ng ml−1 of selenium, and the estimated limit of detection was 6 pg ml−1. The precision of the isotope ratios was close to the theoretical values for selenium concentrations at 1 and 10 ng ml−1. The accuracy of the isotope ratios, however, was improved by correcting the count rate of all selenium isotopes equivalent to the formation of SeH at 9.6 ± 0.5% one mass unit above the selenium isotopes. A linear relationship (r < 0.98) was found between the error of the corrected isotope ratios and the difference in mass from the 80Se reference isotope. This indicated that the error was caused by mass bias. The slope of the curve at −3.0% error per mass unit can be used for correction of the measured ratios. Deuterated methane used as the DRC gas showed that hydrogen transfer from methane was not involved in the formation of SeH as SeD was absent in the mass spectrum. The almost interference-free detection of selenium by ICP-DRC-MS made the detection of the 80Se isotope possible for detection of selenoamino acids separated by cation exchange HPLC. The limit of detection of the HPLC-ICP-DRC-MS method was in the range 3–5 pg as selenium.