Bingkai Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Bingkai Liu has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
- Lin Wen
Xinjiang Technical Institute of Physics and Chemistry, Chinese Academy of Sciences
13 shared publications - Qi Guo
Xinjiang Technical Institute of Physics and Chemistry, Chinese Academy of Sciences
12 shared publications - Yudong Li
Xinjiang Technical Institute of Physics and Chemistry, Chinese Academy of Sciences
12 shared publications - Jie Feng
Xinjiang Technical Institute of Physics and Chemistry, Chinese Academy of Sciences
7 shared publications Yihao Cui
Xinjiang Technical Institute of Physics and Chemistry, Chinese Academy of Sciences
6 shared publicationsZitao Zhao
Xinjiang Technical Institute of Physics and Chemistry, Chinese Academy of Sciences
6 shared publications
Latest Publications
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 73 (10) , 3927-3934
Comparative Study of Low-Temperature and Room-Temperature Proton-Induced Dark Current and Annealing Effects on CMOS Image Sensors
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 73 (10) , 3927-3934
Comparative Study of Low-Temperature and Room-Temperature Proton-Induced Dark Current and Annealing Effects on CMOS Image Sensors
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 73 (10) , 3955-3961
Multiple-Temperature Annealing of Dark Current in TDI CMOS Image Sensors: Anomalous Phenomena and Predictive Modeling
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 73 (10) , 3955-3961
Multiple-Temperature Annealing of Dark Current in TDI CMOS Image Sensors: Anomalous Phenomena and Predictive Modeling
- 1 September 2026
- Published by Taylor & Francis in Radiation Effects and Defects in Solids
- p. 1-12
Total ionizing dose effects on backside-illuminated CMOS image sensors through experiments and TCAD simulations
1. With the development of aerospace technology, space imaging missions impose a higher performance requirement on solid-state imaging devices. Backside-illuminated CMOS image sensor (BSI CIS) has ...
- 1 September 2026
- Published by Taylor & Francis in Radiation Effects and Defects in Solids
- p. 1-12
Total ionizing dose effects on backside-illuminated CMOS image sensors through experiments and TCAD simulations
1. With the development of aerospace technology, space imaging missions impose a higher performance requirement on solid-state imaging devices. Backside-illuminated CMOS image sensor (BSI CIS) has ...
- 1 September 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 73 (9) , 3629-3636
Proton Radiation Effects on 6T CMOS Image Sensors With Standard and Binning Mode
- 1 September 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 73 (9) , 3629-3636
Proton Radiation Effects on 6T CMOS Image Sensors With Standard and Binning Mode
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 73 (8) , 1
Recovery from Displacement Damage on CMOS Image Sensors through Laser Annealing
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 73 (8) , 1
Recovery from Displacement Damage on CMOS Image Sensors through Laser Annealing
- 23 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (23) , 42675-42682
Total Ionizing Dose and Annealing Effects in TDI CMOS Image Sensors
Time delay integration (TDI) CMOS image sensors (CIS) is a specialized type of linear array image sensor with wide applications in space-based remote sensing. This study investigates its total ionizing dose (TID) and annealing effects. After γ-ray irradiation, the device exhibited a decrease in charge transfer efficiency (CTE) and a significant increase in dark current. The quantum efficiency (QE) degradation was more pronounced in the short-wavelength region than in the long-wavelength region. Experimental results revealed the relationship between column fixed pattern noise (CFPN), row fixed pattern noise (RFPN), and TID: under non-irradiated and low-TID conditions, RFPN is the primary noise source, appearing as distinct periodic horizontal stripes in the image; under higher TID conditions, CFPN becomes dominant, and the image features shift to prominent periodic vertical stripes. This finding provides a theoretical basis for post-processing image correction. Notably, most parameters showed varying degrees of recovery after high-temperature annealing at 80 °C and 150 °C, whereas dark current exhibited reverse annealing. When the annealing temperature was raised to 200 °C, the dark current dropped sharply, indicating that the choice of annealing temperature plays a critical role in restoring the performance of TDI CIS after irradiation.
- 23 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (23) , 42675-42682
Total Ionizing Dose and Annealing Effects in TDI CMOS Image Sensors
Time delay integration (TDI) CMOS image sensors (CIS) is a specialized type of linear array image sensor with wide applications in space-based remote sensing. This study investigates its total ionizing dose (TID) and annealing effects. After γ-ray irradiation, the device exhibited a decrease in charge transfer efficiency (CTE) and a significant increase in dark current. The quantum efficiency (QE) degradation was more pronounced in the short-wavelength region than in the long-wavelength region. Experimental results revealed the relationship between column fixed pattern noise (CFPN), row fixed pattern noise (RFPN), and TID: under non-irradiated and low-TID conditions, RFPN is the primary noise source, appearing as distinct periodic horizontal stripes in the image; under higher TID conditions, CFPN becomes dominant, and the image features shift to prominent periodic vertical stripes. This finding provides a theoretical basis for post-processing image correction. Notably, most parameters showed varying degrees of recovery after high-temperature annealing at 80 °C and 150 °C, whereas dark current exhibited reverse annealing. When the annealing temperature was raised to 200 °C, the dark current dropped sharply, indicating that the choice of annealing temperature plays a critical role in restoring the performance of TDI CIS after irradiation.
- 23 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 71 (11) , 2393-2399
High Total Ionizing Dose Effects on Backside-Illuminated CMOS Image Sensors
We recently evaluate the high total ionizing dose (TID) effects on 0.18 μm backside illuminated CMOS image sensors (BSI CIS) with different epitaxial layer thicknesses and backside oxide passivation techniques. γ-irradiated device exhibits a huge dark current increase and quantum efficiency degradation. Moreover, a significant dark current nonuniformity on the whole array is observed at high TID. Results show that the BSI CIS does not capture images and all the functionality is lost after 4 Mrad(SiO 2 ). It is observed that BSI CIS using Al2O3 film as passivation technique is proven to be more efficient in mitigating high TID effects compared to the imagers using boron implant, suggesting that passivation technique options play a crucial role in determining the performance of BSI CIS at high TID level.
- 23 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 71 (11) , 2393-2399
High Total Ionizing Dose Effects on Backside-Illuminated CMOS Image Sensors
We recently evaluate the high total ionizing dose (TID) effects on 0.18 μm backside illuminated CMOS image sensors (BSI CIS) with different epitaxial layer thicknesses and backside oxide passivation techniques. γ-irradiated device exhibits a huge dark current increase and quantum efficiency degradation. Moreover, a significant dark current nonuniformity on the whole array is observed at high TID. Results show that the BSI CIS does not capture images and all the functionality is lost after 4 Mrad(SiO 2 ). It is observed that BSI CIS using Al2O3 film as passivation technique is proven to be more efficient in mitigating high TID effects compared to the imagers using boron implant, suggesting that passivation technique options play a crucial role in determining the performance of BSI CIS at high TID level.