JCJing Cai

Jing Cai

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jing Cai has a total of 24 co-authors. Here are the top co-authors by number of shared publications:

  • Gongpu Lan

    Guangdong-Hong Kong-Macao Joint Laboratory for Intelligent Micro-Nano Optoelectronic Technology, School of Physics and Optoelectronic Engineering, Foshan University, Foshan 528000, China

    3 shared publications
  • Yan-Ping Huang

    Guangdong-Hong Kong-Macao Joint Laboratory for Intelligent Micro-Nano Optoelectronic Technology, School of Physics and Optoelectronic Engineering, Foshan University, Foshan 528000, China

    3 shared publications
  • Chaitanya Ss Duvvuri

    College of Optometry, University of Houston, Houston, TX 77204, USA

    2 shared publications
  • Jia Qin

    Guangdong Weiren Meditech Co., Ltd, Innovation and Entrepreneurship Teams Project of Guangdong Pearl River Talents Program, Foshan, China

    2 shared publications
  • Jingjiang Xu

    Guangdong-Hong Kong-Macao Joint Laboratory for Intelligent Micro-Nano Optoelectronic Technology, School of Physics and Optoelectronic Engineering, Foshan University, Foshan 528000, China

    2 shared publications
  • Jinping Feng

    Institute of Engineering and Technology, Hubei University of Science and Technology, Xianning 437100, China

    2 shared publications

Latest Publications

  • Open Access

    An Efficient OCT Fingerprint Antispoofing Method Based on ResMamba

    by Xinyan Mai, Miaohua Chen, Zhaodong Lu, Shengkai Yang, Gongpu Lan, Yanping Huang, Jia Qin, Lin An, Jingjiang Xu, Jing Cai

    Optical coherence tomography (OCT), known for its noncontact and 3D imaging capabilities, has found widespread application in fingerprint antispoofing detection. However, the existing methods rely heavily on single-frame B-scan images, underutilizing the 3D spatial information inherent in OCT volume data. High computational costs further limit its practical applications. Thus, this study proposes an efficient fingerprint antispoofing method which leverages the spatial continuity of OCT volume data to enhance both the accuracy and computational efficiency. Using an OCT system, we collected 320 real fingerprints and 320 spoofed fingerprints. Then, to distinguish between genuine and spoofed fingerprints, we developed the proposed ResMamba model, which is based on an enhanced 3D convolutional network integrated with a state space model (SSM). We extracted regions of interest (ROIs) from B-scan images and segmented them into volume slices for training and classification. The experimental results demonstrate that ResMamba achieved a 0.56% error rate (ERR) and 99.22% area under the curve (AUC), with an inference time of just 11 ms. Furthermore, compared to the existing models, ResMamba effectively balances its accuracy, inference speed, and model size. Ablation studies confirm that integrating the SIC module enhances the model’s robustness. Overall, ResMamba offers an efficient and reliable fingerprint antispoofing solution, outperforming the traditional methods in terms of its accuracy and performance.


  • Open Access

    Corneal Surface Wave Propagation Associated with Intraocular Pressures: OCT Elastography Assessment in a Simplified Eye Model

    by Guoqin Ma, Jing Cai, Rijian Zhong, Weichao He, Haoxi Ye, Chaitanya Duvvuri, Chengjin Song, Jinping Feng, Lin An, Jia Qin, et al.

    Assessing corneal biomechanics in vivo has long been a challenge in the field of ophthalmology. Despite recent advances in optical coherence tomography (OCT)-based elastography (OCE) methods, controversy remains regarding the effect of intraocular pressure (IOP) on mechanical wave propagation speed in the cornea. This could be attributed to the complexity of corneal biomechanics and the difficulties associated with conducting in vivo corneal shear-wave OCE measurements. We constructed a simplified artificial eye model with a silicone cornea and controllable IOPs and performed surface wave OCE measurements in radial directions (54–324°) of the silicone cornea at different IOP levels (10–40 mmHg). The results demonstrated increases in wave propagation speeds (mean ± STD) from 6.55 ± 0.09 m/s (10 mmHg) to 9.82 ± 0.19 m/s (40 mmHg), leading to an estimate of Young’s modulus, which increased from 145.23 ± 4.43 kPa to 326.44 ± 13.30 kPa. Our implementation of an artificial eye model highlighted that the impact of IOP on Young’s modulus (ΔE = 165.59 kPa, IOP: 10–40 mmHg) was more significant than the effect of stretching of the silicone cornea (ΔE = 15.79 kPa, relative elongation: 0.98–6.49%). Our study sheds light on the potential advantages of using an artificial eye model to represent the response of the human cornea during OCE measurement and provides valuable insights into the impact of IOP on wave-based OCE measurement for future in vivo corneal biomechanics studies.


  • Open Access

    Corneal Surface Wave Propagation Associated with Intraocular Pressures: OCT Elastography Assessment in a Model Eye

    by Guoqin Ma, Jing Cai, Rijian Zhong, Weichao He, Haoxi Ye, Chaitanya Ss Duvvuri, Chengjin Song, Jinping Feng, Lin An, Jia Qin, et al.

    Assessing corneal biomechanics in vivo has long been a challenge in the field of ophthalmology. Although recent wave-based optical coherence elastography (OCE) methods have shown promise in this area, the effect of intraocular pressure (IOP) on mechanical wave propagation in the cornea remains unclear. To address this, we constructed an artificial eye model and performed surface wave OCE measurements in the radial directions (54–324°) of the silicone cornea at varying IOP levels (10–40 mmHg). The results demonstrated increases in wave propagation speeds (mean ± STD) from 6.55 ± 0.09 m/s (10 mmHg) to 9.82 ± 0.19 m/s (40 mmHg), leading to an estimate of Young’s modulus, which increased exponentially from 145.23 ± 4.43 kPa to 326.44 ± 13.30 kPa. Our implementation of an artificial eye model highlighted that the impact of IOP on Young’s modulus (ΔE = 165.59 kPa, IOP: 10–40 mmHg) was more significant than the effect of stretching of the silicone cornea (ΔE = 15.79 kPa, relative elongation: 0.98%–6.49%). Our study sheds light on the potential of using an artificial eye model in OCE research for corneal biomechanics. Furthermore, it is critical to consider the impact of IOP on measurement results when utilizing wave-based OCE in clinical settings for enhanced assessment of corneal biomechanics.